Niaz Hamaghareeb Hamasaeed

Prof. Dr. Niaz Hamaghareeb Hamasaeed

Conservative Dentistry, Hawler Medical University, Erbil, Arbīl, Iraq
orcid
Professor Dr. Niaz Hamagareeb Hamasaeed

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 November 2023 in Cellular and Molecular Biology
Verified
Journal Article
Open access
PDF file
NANA Bahra H. Agha
NA Bahra H. Agha
Niaz Hamaghareeb HamasaeedNiaz Hamaghareeb Hamasaeed
Niaz Hamaghareeb Hamasaeed
Faiq HussainFaiq Hussain
Faiq Hussain
The direct mixing of Nano-hydroxyapatite with Resin Adhesive often leads to weak molecular interactions, which can compromise the dispersion of Nano-hydroxyapatite within the resin adhesive and cause structural damage to the Nano-hydroxyapatite. Therefore, the present study aimed to identify an approach in which Nano-hydroxyapatite is charged or modified prior to its integration into resin adhesive. In this study, Nano-hydroxyapatite was modified using aminopropyltriethoxysilane (APTS), subsequently, the amine groups present on the surface of Nano-hydroxyapatite were additionally modified using succinic anhydride. This modification process resulted in the production of negatively charged Nano-hydroxyapatite - aminopropyltriethoxysilane (n-HA-APTS-SAH). The charged Nano-hydroxyapatite particles were characterized using FTIR and SEM. Subsequently, the charged Nano-hydroxyapatite particles were incorporated into resin dental adhesive. Comprehensive characterization of the composite material was carried out through SEM, FTIR, EDX mapping, and Micro-Raman Spectroscopy. The results revealed the presence of Nano-hydroxyapatite in the mixture and a homogeneous and well-dispersed state with no observable aggregation of Nano-hydroxyapatite particles within the adhesive. Furthermore, the particles still maintain a spherical shape with their sizes falling within the nanoscale range.

1 April 2023 in Journal of Advanced Pharmaceutical Technology & Research
Verified
Journal Article
Open access
PDF file
AMAmal Alaa Mawlood
Amal Alaa Mawlood
Niaz Hamaghareeb HamasaeedNiaz Hamaghareeb Hamasaeed
Niaz Hamaghareeb Hamasaeed
The study's main objective was to evaluate as well as compare the impact of diode laser 940 nm and conventional in-office bleaching technique on the color change of different composite resin restorations. A total of ninety composite resin discs (CRDs) were made from Filtek™ Bulk Fill, nanohybrid composite resin Filtek™ Z550 XT Universal Restorative, and flowable composite resin restoration Filtek™ Z350xt Flowable Composite. Group A: (30) CRD for Filtek™ Bulk Fill, group B: (30) CRD for Filtek™ Z550 XT Universal Restorative, and group C: (30) CRD for Filtek™ Z350xt Flowable Composite. A1, B1, and C1: (10 CRD in each group): Control group without bleaching. A2, B2, and C2: 10 CRD in each group bleached with Laser White20 without laser activation. A3, B3, and C3: 10 CRD in each group bleached with Laser White20 and activated by diode laser 940 nm. The color was evaluated using a dental spectrophotometer. One-way ANOVA was utilized for the comparison of the color stability of the CRD. P < 0.05 is regarded as statically significant. Both conventional and diode laser in-office vital tooth bleaching protocols affected the color stability of composite resin restorations. The result demonstrated that bleaching without laser activation produced color change (mean [8.30], standard deviation [SD] (1.95) P [< 0.001]), whereas the bleaching and activation by diode laser produced color change (mean [8.11], SD [1.99], P [< 0.001]). Both types of bleaching protocol affected composite resin restorations' color stability. In all tested materials, color changes after the bleaching protocol were clinically perceptible. The restorations following the bleaching procedure are required to be replaced by clinicians.

31 December 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Niaz Hamaghareeb HamasaeedNiaz Hamaghareeb Hamasaeed
Niaz Hamaghareeb Hamasaeed
ITIntesar Saadallah Toma
Intesar Saadallah Toma
Adil Othman AbdullahAdil Othman Abdullah
Adil Othman Abdullah
SKShakhawan Kadir Kadir
Shakhawan Kadir Kadir
(1) Background: The objective of the current investigation was to determine how different dark chocolate concentrations impacted the enamel and dentine microhardness. (2) Methods: Twenty noncarious premolar teeth extracted for orthodontic reasons were used in this study. Each tooth was divided mesiodistally to obtain 40 specimens of enamel and dentine 4 × 4 mm. Initial and final assessments of the surface microhardness of the enamel and dentine were created using a Digital Micro Vickers Hardness Tester (Laryee, Beijing, China) under (0.24 N load for 15 s). Four random groups (n = 10) were created: G1 (control, immersed in artificial saliva), G2 (70%), G3 (85%), and G4 (100% dark chocolate). Each sample underwent four cycles of 60-s immersion in suggested concentrations, followed by 30 min in artificial saliva. The attained values underwent statistical analysis employing SPSS version 26, with the utilization of T-tests and ANOVA. (3) Results: The results revealed a significant, incremental increase in the average microhardness values for enamel, specifically 61.72 ± 22.729, 64.17 ± 23.397, and 109.15 ± 34.625, and for dentin from 57.91 ± 8.332 to 72.29 ± 2.752 and ultimately reaching 88.67 ± 8.602, corresponding to the escalating concentrations of dark chocolate (70%, 85%, and 100%) (p < 0.001). (4) Conclusions: Immersing the specimens in different concentrations of dark chocolate had a significant positive impact on the microhardness of both enamel and dentine.
1

1 January 2024 in International Journal of Biomaterials
Verified
Journal Article
Open access
HAhidayat ababakr
hidayat ababakr
DBDiyar Khalid Bakr
Diyar Khalid Bakr
Niaz Hamaghareeb HamasaeedNiaz Hamaghareeb Hamasaeed
Niaz Hamaghareeb Hamasaeed
SSSazan Sherdl Saleem
Sazan Sherdl Saleem
SMSohela Fakher Mahdi
Sohela Fakher Mahdi
HTHozan Farid Tawfiq
Hozan Farid Tawfiq
A layer of smear that coats the walls of root canals is produced by root canal instrumentation, which could be unfavorable to endodontic therapy. The endodontic irrigant SmearOFF is designed to effectively remove both the smear layer and bacteria concurrently. The objective of this study was to evaluate and compare the efficacy of SmearOFF and 17% EDTA in removing the smear layer across the coronal, middle, and apical thirds of root canals. Sixty‐four single‐canal mandibular premolar roots were chosen. Two irrigant protocols were separated into two sets of thirty‐two teeth, respectively, Group 1 (6% NaOCL/SmearOFF) and Group 2 (6% NaOCl/17% EDTA.) Until X2, the ProtaperNext rotary system (Dentsply, Maillefer, Switzerland), with a COXO C‐SMART Endomotor (Foshan COXO Medical instrument Co., Ltd., China) was utilized for the shaping of all teeth, the equipment settings were tuned to 300 revolutions per minute (rpm) and a torque of 3 Newton‐centimeters (Ncm). Before applying the final irrigants, an initial irrigation with 6% sodium hypochlorite (NaOCl) was performed using a 27‐G side‐vented needle. An ultrasonic gadget, EndoUltra, was utilized to activate the irrigation. After that, the determination of how well the proposed solutions worked on the prepared teeth was conducted by scanning electron microscopy. The mean smear layer scores were lower in all three regions (coronal, middle, and apical) using 17% EDTA in comparison with the samples treated with SmearOFF. Despite that, there were no significant differences between G1, 6% NaOCL/SmearOFF and G2, 6% NaOCL/17% EDTA in smear layer removal according to Kruskal–Wallis tests and Mann–Whitney U‐tests (p < 0.05). Considering the findings of this investigation, both 17% EDTA and SmearOFF serve as chelating agents, demonstrating the capability to effectively remove the smear layer. This process is facilitated with the assistance of passive ultrasonic irrigation at intervals of every third of the root canal.

26 March 2025 in Journal of Medical and Health Studies
Verified
Journal Article
Open access
PDF file
THTara Saleem Hamad
Tara Saleem Hamad
Niaz Hamaghareeb HamasaeedNiaz Hamaghareeb Hamasaeed
Niaz Hamaghareeb Hamasaeed
Orthodontic treatments, particularly fixed brackets and invisalign clear aligners, are known to alter the oral microbiome, potentially influencing the prevalence of oral pathogens. This study aimed to determine the impact of these orthodontic appliances on the distribution of Porphyromonas gingivalis, Streptococcus mutans, and Streptococcus sobrinus in saliva samples using absolute quantitative real-time PCR. This cross-sectional study conducted in Erbil-Iraq from February 2025 to April 2025. Ninety subjects were divided into three groups for this analysis: thirty subjects with metallic fixed orthodontic appliances, thirty subjects with Invisalign aligners, and thirty as a control group without any orthodontic appliances. Unstimulated salivary samples were collected, and then bacterial DNA was extracted and target bacterial pathogens were quantified using absolute quantitative Real-Time PCR. The total bacterial load was significantly higher in the fixed bracket group (5.4 × 10⁵ ± 3.5 × 10⁵ CFU/μl) compared to the controls (p=0.002). Streptococcus mutans was present in all groups, with significantly higher levels in fixed bracket users (3.6 × 10⁴ ± 2.3 × 10⁴ CFU/μl) compared to clear aligner users (7.5 × 10³ ± 6.9 × 10³ CFU/μl) and controls (1 × 10³ ± 3.2 × 10³ CFU/μl). The prevalence of Porphyromonas gingivalis was higher in fixed bracket users (100%) compared to clear aligner users (93.3%) and controls (90%). There were no significant differences in the levels of Porphyromonas gingivalis, Streptococcus sobrinus, or total bacterial load between the clear aligner and control group (p>0.05). Fixed brackets contribute to higher bacterial loads, particularly Streptococcus mutans. In contrast, Invisalign clear aligners have less impact on oral pathogens, potentially offering advantages for maintaining oral hygiene during orthodontic treatment.

30 December 2025 in Erbil Dental Journal
Verified
Journal Article
Open access
PDF file
LHLaween Nzar Hassan
Laween Nzar Hassan
Niaz Hamaghareeb HamasaeedNiaz Hamaghareeb Hamasaeed
Niaz Hamaghareeb Hamasaeed
SKShakhawan Kadir Kadir
Shakhawan Kadir Kadir
Background and Objectives: Adequate knowledge of anatomic variations in root canal morphology is essential for improving the outcome of root canal treatment. The maxillary first molars commonly require endodontic treatment; however, they are known to have the most complex root canal systems. Aim: To evaluate the frequency of the second mesiobuccal (MB2) canal and the second distobuccal (DB2) canal in maxillary first molars, as well as the bilateral symmetry of the maxillary first molars (MFM) with the second mesiobuccal canal, and the association of gender and age to their occurrence using cone beam computed tomography (CBCT). Methods: This retrospective study investigated 140 maxillary first molars from 80 CBCT scans collected from a private dental imaging centre in Hawler over 4 months from May to August 2024. The patients were aged 13 to 57 years (mean age: 29.1 years). Data were analysed using SPSS (version 25) with descriptive statistics and the Chi-Square test. Results: The prevalence of the MB2 canal in MFM was 53.6%. Both males and females have a similar prevalence of MB2 canals in their MFM. In 75 MFM with MB2 canals, a single apical exit was found in 51.9% of the cases. No significant correlation was found between the prevalence of the MB2 canal and gender or age. In the 41 patients with MB2 canals in their MFM, the likelihood of bilateral MB2 canals was high (82.9%). The frequency distribution of the second distobuccal canal was low (7.9%); however, the age group 21-30 showed the highest occurrence of second distobuccal canals in MFM. Conclusion: The use of CBCT is a valuable tool in detecting MB2 canals, therefore improving the outcomes of root canal treatment. A high prevalence of MB2 canals was found in the study. The prevalence of bilateral MB2 was high. Keywords: Cone Beam Computed Tomography (CBCT), Maxillary first molar, MB2, Root canal system, Distobuccal canal.