Diyar Khalid Bakr

Prof. Dr. Diyar Khalid Bakr

College of Dentistry, Hawler Medical University, Erbil, Arbīl, Iraq
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 October 2022 in Applied Bionics and Biomechanics
Verified
Journal Article
Open access
PDF file
HUHana R. Ubaed
Hana R. Ubaed
DBDiyar Khalid Bakr
Diyar Khalid Bakr
Objective. Cyclic fatigue occurred in the curved canal when the instrument freely rotated leading to repeated compressive and tensile stresses. This study aims to evaluate the cyclic fatigue resistance (CFR) of new and used 2Shape and AF F-One rotary instrument systems by using an artificial stainless-steel canal. Methods. A total of 80 rotary nickel–titanium (NiTi) instruments of two systems were used, 2Shape/TS2 and AF F-ONE/F5 (40 in each group). The instruments were subdivided into group A 20 instruments (10 per system) that remain unused, group B 20 instruments (10 per system) instrumented 20 root canals (each file prepared 1 canal for 2 minutes), group C 20 instruments (10 per system) instrumented 40 canals each for 2 minutes (each file prepared 2 canals), group D of 20 instruments (10 per system) prepared 60 canals each for 2 minutes (each file prepared 3 canals). After each canal instrumentation, the instruments were cleaned and sterilized by autoclave. Then, all the instruments underwent cyclic fatigue testing in an artificial stainless steel canal with a 50° canal curvature and a radius of curvature of 5 mm. The time and number of cycles to failure (NCF) were recorded. Data were analyzed using the Welch ANOVA test for intragroup comparison and the pairwise test for multiple comparisons. Results. The unused instruments of the AF F-One rotary system showed statistically higher CFR than clinically used instruments ( P < 0.05 ). 2Shape system was not affected by clinical use ( P > 0.05 ). The mean NCF of AF F-One instruments was significantly higher than the equivalent file group of 2Shape instruments ( P < 0.05 ). Conclusion. A reduction in the CFR for AF F-One instruments after use was observed when compared to the new unused file group. The 2Shape system was not affected by clinical use. AF F-One performed better in terms of NCF.

1 January 2024 in International Journal of Biomaterials
Verified
Journal Article
Open access
HAhidayat ababakr
hidayat ababakr
DBDiyar Khalid Bakr
Diyar Khalid Bakr
Niaz Hamaghareeb HamasaeedNiaz Hamaghareeb Hamasaeed
Niaz Hamaghareeb Hamasaeed
SSSazan Sherdl Saleem
Sazan Sherdl Saleem
SMSohela Fakher Mahdi
Sohela Fakher Mahdi
HTHozan Farid Tawfiq
Hozan Farid Tawfiq
A layer of smear that coats the walls of root canals is produced by root canal instrumentation, which could be unfavorable to endodontic therapy. The endodontic irrigant SmearOFF is designed to effectively remove both the smear layer and bacteria concurrently. The objective of this study was to evaluate and compare the efficacy of SmearOFF and 17% EDTA in removing the smear layer across the coronal, middle, and apical thirds of root canals. Sixty‐four single‐canal mandibular premolar roots were chosen. Two irrigant protocols were separated into two sets of thirty‐two teeth, respectively, Group 1 (6% NaOCL/SmearOFF) and Group 2 (6% NaOCl/17% EDTA.) Until X2, the ProtaperNext rotary system (Dentsply, Maillefer, Switzerland), with a COXO C‐SMART Endomotor (Foshan COXO Medical instrument Co., Ltd., China) was utilized for the shaping of all teeth, the equipment settings were tuned to 300 revolutions per minute (rpm) and a torque of 3 Newton‐centimeters (Ncm). Before applying the final irrigants, an initial irrigation with 6% sodium hypochlorite (NaOCl) was performed using a 27‐G side‐vented needle. An ultrasonic gadget, EndoUltra, was utilized to activate the irrigation. After that, the determination of how well the proposed solutions worked on the prepared teeth was conducted by scanning electron microscopy. The mean smear layer scores were lower in all three regions (coronal, middle, and apical) using 17% EDTA in comparison with the samples treated with SmearOFF. Despite that, there were no significant differences between G1, 6% NaOCL/SmearOFF and G2, 6% NaOCL/17% EDTA in smear layer removal according to Kruskal–Wallis tests and Mann–Whitney U‐tests (p < 0.05). Considering the findings of this investigation, both 17% EDTA and SmearOFF serve as chelating agents, demonstrating the capability to effectively remove the smear layer. This process is facilitated with the assistance of passive ultrasonic irrigation at intervals of every third of the root canal.

30 April 2023 in Cellular and Molecular Biology
Verified
Journal Article
Open access
PDF file
SRSaya Hadi Raouf
Saya Hadi Raouf
DBDiyar Khalid Bakr
Diyar Khalid Bakr
UAUrfa Muneer Ahmed
Urfa Muneer Ahmed
Bassam Karem AminBassam Karem Amin
Bassam Karem Amin
Failure of endodontic treatment is closely associated with bacterial infection, the study aimed to evaluate the antibacterial properties of MTA- Fillapex and BIO-C against two bacterial species Enterococcus faecalis (E. faecalis) and Staphylococcus aureus (S. aureus). In this in vitro study, two endodontic sealers were used to evaluate antibacterial properties by using an agar diffusion test (ADT) and direct contact test (DCT). The width of the growth inhibition zone after 24 hours was reported in (ADT) as the endodontic sealers' effectiveness. In DCT, the survival of microorganisms was assessed at various periods following the exposure of the bacterial suspension to the sealers for (20 and 40 min) at (1 day, 7 days and 14 days). Colony-forming unit (CFU) counts were made. In ADT, the zones of microbial growth inhibition in BIO-C sealer caused by E. Facealis were relatively larger than that created due to S. Auerous bacteria with mean 0.781 mm and 0.538 mm respectively. Thus, this difference turned out to be significant (p 0.05). In terms of sealers, BIO-C had the most potent antimicrobial properties. It showed significant inhibition against both E.faecalis and S. Auerous on day 1 and the first week of contact times tested. Moreover both BIO-C and MTA Fillapex sealers perform worthy antibacterial activity up to 1 week and BIO-C sealers show better antibacterial efficacy against E. faecalis than MTA Fillapex sealers.

16 December 2025 in Coatings
Verified
Journal Article
Open access
PDF file
zakaria mohammadzakaria mohammad
zakaria mohammad
DBDiyar Khalid Bakr
Diyar Khalid Bakr
The existing scientific literature indicates that flowable short fiber-reinforced composites (SFRCs) can be used for direct restoration due to their favorable mechanical properties. However, there is a lack of data on the mechanical properties of SFRCs designed specifically for indirect CAD/CAM restorations. This study aims to fabricate a novel experimental SFRC CAD/CAM block and evaluate its fracture toughness and polishability as an indirect restoration in comparison with different conventional resin-based CAD/CAM blocks with different compositions. Fourier-transform infrared spectroscopy (FTIR) was employed to analyze the chemical structure of the Experimental SFRC group, while the microstructure of specimens from each group was examined using scanning electron microscopy (SEM). Then, this study divided the specimens into three groups—Group 1 (Grandio blocks), Group 2 (Cerasmart 270), and Group 3 (Experimental SFRC)—with 30 specimens in each group. Each group was then subdivided into sub-groups for the fracture toughness test, which evaluated resistance to crack propagation, and the surface roughness test, which assessed surface topography. FTIR analysis showed that the experimental SFRC exhibited distinct spectral changes after polymerization, confirming successful chemical reactions and network formation. SEM analysis showed that the Experimental SFRC block had a polymeric matrix with randomly oriented, well-dispersed short fibers. Grandio blocs exhibited a dense nanohybrid structure with irregular fillers, while Cerasmart 270 displayed a more uniform microstructure with evenly dispersed nano-sized spherical fillers. The Experimental SFRC showed the highest fracture toughness (2.758 MPa·√m), surpassing the other groups (p < 0.05) and highlighting its superior resistance to crack propagation. Regarding surface roughness Ra, the novel Experimental SFRC group (0.182) presented a significant difference compared to other groups (p < 0.05) but within clinical acceptance, and they can be well polished for clinical use after milling. The Cerasmart 270 block showed the lowest surface roughness Ra (0.135) among the groups, which is attributed to its filler size, geometry, and composition, resulting in a smoother surface. The higher fracture toughness of the Experimental SFRC among the groups suggests superior resistance to crack propagation, attributed to the incorporation of short fibers that enhance energy absorption and reduce brittleness, thereby supporting its suitability for high-stress-bearing clinical applications.

6 August 2025 in Ceramics
Verified
Journal Article
Open access
PDF file
Hala Butrus KakaHala Butrus Kaka
Hala Butrus Kaka
NANsar Azeez
Nsar Azeez
DBDiyar Khalid Bakr
Diyar Khalid Bakr
Media SaeedMedia Saeed
Media Saeed
Efforts to enhance the mechanical and physicochemical properties of conventional glass ionomer cement (GIC) are ongoing. This study aimed to evaluate the effect of incorporating varying concentrations of frankincense and myrrh liquids into conventional GIC on its microhardness and sealing ability. Frankincense and myrrh liquids were prepared by dissolving 25 g of each ground resin in 50 mL of distilled water at 60 °C and allowing the solutions to stand for 8 h. Five experimental groups were evaluated: Group A (conventional GIC), Group B (15% frankincense-modified GIC), Group C (25% frankincense-modified GIC), Group D (15% myrrh-modified GIC), and Group E (25% myrrh-modified GIC). Microhardness was evaluated using a Vickers hardness tester, and sealing ability was evaluated via interfacial gap measurements using scanning electron microscopy (SEM). SEM analysis revealed that all modified GIC groups exhibited significantly smaller interfacial gap sizes (Groups B–E: 6.1, 5.22, 5.9, and 5.34 µm, respectively) compared to conventional GIC (Group A: 6.88 µm). However, there were no statistically significant differences in microhardness among the groups (p > 0.5). The incorporation of 15% and 25% concentrations of frankincense or myrrh liquids into conventional GIC significantly improved sealing ability without compromising hardness.

4 June 2026 in Advanced medical journal
Verified
Journal Article
Open access
TRTwana Jalal Rasool
Twana Jalal Rasool
DBDiyar Khalid Bakr
Diyar Khalid Bakr
Background and objectives: The mandibular first molars have a variety of abnormal canal morphologies; many authors have researched the frequency of these anatomical variants and their relationship to gender. The objective of this study is to analyze root canal morphology using Cone-Beam Computed Tomography in Erbil population. Method: This retrospective study, conducted in Erbil in the Kurdistan region of Iraq from January 2023 to January 2024, evaluates Cone-Beam Computed Tomography images of 100 mandibular first molars. The evaluation focused on the following details: the number of roots, the number of apical foramina, the frequency distribution of root canal configurations based on Vertucci’s classification, and the frequency of occurrence of both the middle mesial canal and radix entomolaris. Result: The study included 100 patients. The middle mesial canal was present in 3.7% of patients under 30 years old, compared with 2.2% of those aged 30 years or older (p = 1.000). Four out of 100 patients (4%) had three roots, while the remaining patients had two roots. Only 4% of the sample exhibited radix entomolaris. Conclusion: Mandibular first molars typically have two main roots. Type I is the most common shape for distal canal, while for the mesial canal, type II, IV are more common, with middle-aged individuals showing a higher frequency of middle mesial canals. Variation also occurs in root number, apical foramina presence, extra roots and different canal configuration.