Paola Papaleo

Dr. Paola Papaleo

Department of Industrial Engineering, University of Bologna, Bologna, Emilia-Romagna, Italy
orcid

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 May 2021 in Bioengineering
Verified
Journal Article
Open access
PDF file
Leonardo FrizzieroLeonardo Frizziero
Leonardo Frizziero
GSGian Maria Santi
Gian Maria Santi
CLCHRISTIAN EDMUNDO LEON-CARDENAS
CHRISTIAN EDMUNDO LEON-CARDENAS
GDGiampiero Donnici
Giampiero Donnici
Alfredo LiveraniAlfredo Liverani
Alfredo Liverani
PZPaola Zarantonello
Paola Zarantonello
Three-dimensional printed custom cutting guides (CCGs) are becoming more and more investigated in medical literature, as a patient-specific approach is often desired and very much needed in today’s surgical practice. Three-dimensional printing applications and computer-aided surgical simulations (CASS) allow for meticulous preoperatory planning and substantial reductions of operating time and risk of human error. However, several limitations seem to slow the large-scale adoption of 3D printed CCGs. CAD designing and 3D printing skills are inevitably needed to develop workflow and address the study; therefore, hospitals are pushed to include third-party collaboration, from highly specialized medical centers to industrial engineering companies, thus increasing the time and cost of labor. The aim of this study was to move towards the feasibility of an in-house, low-cost CCG 3D printing methodology for pediatric orthopedic (PO) surgery. The prototype of a femoral cutting guide was developed for its application at the IOR—Rizzoli Orthopedic Institute of Bologna. The element was printed with an entry-level 3D printer with a high-temperature PLA fiber, whose thermomechanical properties can withstand common steam heat sterilization without bending or losing the original geometry. This methodology allowed for extensive preoperatory planning that would likewise reduce the overall surgery time, whilst reducing the risks related to the intervention.

28 July 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Leonardo FrizzieroLeonardo Frizziero
Leonardo Frizziero
GSGian Maria Santi
Gian Maria Santi
Alfredo LiveraniAlfredo Liverani
Alfredo Liverani
FNFrancesca Napolitano
Francesca Napolitano
Paola PapaleoPaola Papaleo
Paola Papaleo
Giovanni TrisolinoGiovanni Trisolino
Giovanni Trisolino
This work aims to present an in-house low-cost computer-aided simulation (CASS) process that was recently implemented in the preoperative planning of complex osteotomies for limb deformities in children. Five patients admitted to the Unit of Paediatric Orthopaedics and Traumatology from April 2018 to December 2019, for correcting congenital or post-traumatic limb deformities were included in the study. Three-dimensional (3D) digital models were generated from Computed Tomography (CT) scans, using free open-source software, and the surgery was planned and simulated starting from the 3D digital model. 3D printed sterilizable models were fabricated using a low-cost 3D printer, and animations of the operation were generated with the aim to accurately explain the operation to parents. All procedures were successfully planned using our CASS method and the 3D printed models were used during the operation, improving the understanding of the severely abnormal bony anatomy. The surgery was precisely reproduced according to CASS and the deformities were successfully corrected in four cases, while in one case, the intraoperative intentional undersizing of the bone osteotomy produced an incomplete correction of a congenital forearm deformity. Our study describes the application of a safe, effective, user-friendly, and low-cost CASS process in paediatric orthopaedics (PO) surgery. We are convinced that our study will stimulate the widespread adoption of this technological innovation in routine clinical practice for the treatment of rare congenital and post-traumatic limb deformities during childhood.

30 August 2021 in Inventions
Verified
Journal Article
Open access
PDF file
Leonardo FrizzieroLeonardo Frizziero
Leonardo Frizziero
Alfredo LiveraniAlfredo Liverani
Alfredo Liverani
GDGiampiero Donnici
Giampiero Donnici
Paola PapaleoPaola Papaleo
Paola Papaleo
CLCHRISTIAN EDMUNDO LEON-CARDENAS
CHRISTIAN EDMUNDO LEON-CARDENAS
This study shows an application of the Design for Six Sigma (DFSS) Methodology in the field of medical engineering. This research aims to demonstrate the application of a systematic design approach in the development of the “Ocane”, an innovative concept of smart cane for visually impaired patients which was thought of in answer to the end user’s needs, deploying an easy to transport, locate, and adjust element with ultrasonic sensors and tactile feedback. DFSS is an analytical design methodology meant to organize project workflow in a sequence of specific steps. Other standardized design procedures such as Quality Function Deployment (QFD) and Stylistic Design Engineering (SDE) have been used to support DFSS in terms of targeting customer requirements and focusing on aesthetics for ergonomics analysis, respectively. First, the QFD process is introduced and applied to gather the final customer needs, completing the analysis with benchmarking and similar-thought products on the market. Afterwards, a description of the DFSS methodology and application to the case study was deployed. Thereafter, the SDE procedure is exposed by identifying the “Ocane” concept and development, and moving towards the completion of an inventive product with a creative design and careful attention to visually impaired clients’ requirements.

29 April 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Leonardo FrizzieroLeonardo Frizziero
Leonardo Frizziero
GSGian Maria Santi
Gian Maria Santi
CLCHRISTIAN EDMUNDO LEON-CARDENAS
CHRISTIAN EDMUNDO LEON-CARDENAS
GDGiampiero Donnici
Giampiero Donnici
Alfredo LiveraniAlfredo Liverani
Alfredo Liverani
PZPaola Zarantonello
Paola Zarantonello
The study of CAD (computer aided design) modeling, design and manufacturing techniques has undergone a rapid growth over the past decades. In medicine, this development mainly concerned the dental and maxillofacial sectors. Significant progress has also been made in orthopedics with pre-operative CAD simulations, printing of bone models and production of patient-specific instruments. However, the traditional procedure that formulates the surgical plan based exclusively on two-dimensional images and interventions performed without the aid of specific instruments for the patient and is currently the most used surgical technique. The production of custom-made tools for the patient, in fact, is often expensive and its use is limited to a few hospitals. The purpose of this study is to show an innovative and cost-effective procedure aimed at prototyping a custom-made surgical guide for address the cubitus varus deformity on a pediatric patient. The cutting guides were obtained through an additive manufacturing process that starts from the 3D digital model of the patient’s bone and allows to design specific models using Creo Parametric. The result is a tool that adheres perfectly to the patient’s bone and guides the surgeon during the osteotomy procedure. The low cost of the methodology described makes it worth noticing by any health institution.

11 May 2021 in Symmetry
Verified
Journal Article
Open access
PDF file
Leonardo FrizzieroLeonardo Frizziero
Leonardo Frizziero
CPCurzio Pagliari
Curzio Pagliari
GDGiampiero Donnici
Giampiero Donnici
Alfredo LiveraniAlfredo Liverani
Alfredo Liverani
GSGian Maria Santi
Gian Maria Santi
SSStefano Stallone
Stefano Stallone
This experimental study defines the usage of a computer-aided surgical simulation process that is effective, safe, user-friendly, and low-cost, that achieves a detailed and realistic representation of the anatomical region of interest. The chosen tools for this purpose are state-of-the-art Computer Aided Design (CAD) software for mechanical design, and are the fundamental application dedicated to parametric modeling. These tools support different work environments, each one is for a specific type of modeling, and they allow the simulation of surgery. The result will be a faithful representation of the anatomical part both before and after the surgical procedure, screening all the intermediate phases. The doctor will assess different lines of action according to the results, then he will communicate them to the engineer who, consequently, will correct the antisymmetric issue and regenerate the model. Exact measurements of the mutual positions of the various components, skeletal and synthetic, can be achieved; all the osteosynthesis tools, necessary for the surgeon, can be included in the project according to different types of fracture to perfectly match the morphology of the bone to be treated. The method has been tested on seven clinical cases of different complexity and nature and the results of the simulations have been found to be of great effectiveness in the phase of diagnosis and of preoperative planning for the doctors and surgeons; therefore, allowing a lower risk medical operation with a better outcome. This work delivers experimental results in line with theoretical research findings in detail; moreover, full experimental and/or methodical details are provided, so that outcomes could be obtained.

1 February 2026 in Eng
Verified
Journal Article
Open access
PDF file
Leonardo FrizzieroLeonardo Frizziero
Leonardo Frizziero
GMGrazia Chiara Menozzi
Grazia Chiara Menozzi
GAGiulia Alessandri
Giulia Alessandri
ADAlessandro Depaoli
Alessandro Depaoli
GDGiampiero Donnici
Giampiero Donnici
GINO ROCCAGINO ROCCA
GINO ROCCA
(1) Background: HTPLA FDM-printed cutting guides enable the low-cost, in-hospital production of patient-specific instruments. However, annealing, which is required for steam sterilization, may alter the dimensions of fit-critical fixation pin holes. (2) Methods: HTPLA cylindrical specimens (height 5 mm) were printed with fixed process parameters and vertical orientation. Inner diameter (1.6–5.0 mm) and wall thickness (2–6 mm) were varied using a two-factor Central Composite Design (n = 13). Following a two-stage annealing treatment (80 °C, 10 min; 100 °C, 50 min), post-annealing dimensions were measured and modeled using Response Surface Methodology. An illustrative verification was performed on additional specimens. (3) Results: Annealing induced a systematic decrease in inner diameter (−0.4 to −0.9 mm) and an increase in wall thickness (+0.1 to +0.4 mm). A reduced quadratic model accurately captured these trends within the investigated range, with small residuals observed during verification (≤0.1 mm). (4) Conclusions: The proposed local, geometry-driven model supports compensation in fixation pin-hole dimensions in annealed HTPLA cutting guides, improving dimensional predictability within a defined design and process window.