There have been tried many types of liquids with different ranges of viscosity values that have been tested to form a single cavitation bubble. The purpose of these experiments was to observe the behaviour of cavitation bubbles in media with different ranges of absorbance. The most of the method was based on spark to induced superheat limit of liquid. Here we used arrangement of the laser-induced breakdown (LIB) method. There were described the set cavitation setting that affects the size bubble in media with different absorbance. We visualized the cavitation bubble with a 60 kHz high speed camera. We used here shadowgraphy setup for the bubble visualization. There were observed time development and bubble extinction in various media, where the size of the bubble in the silicone oil was extremely small, due to the absorbance size of silicon oil.
This article presents the sterilization of bacteria using cavitation bubbles. Cavitation generated by ultrasound creates a cavitation cloud. Therefore is more advantageous to generate the cavitation bubbles by laser-induced breakdown, because it is possible to generate individual bubbles for the purpose of study single impact and physical mechanism of acting. The cavitation bubble is generated by a Nd: YAG 532nm laser beam, a short 10ns pulse. Here, we used optics to focus the laser beam and a high-speed camera to visualize characteristics the bubble. We used the method of long-distance microscopy and shadowgraph lightening for the visualization. We used the particle image velocimetry (PIV) method to determine the interaction of the bubble with the surrounding liquid and solid surface. The main goal of the research is to use cavitation to sterilize bacteria and biofilm in impact of single bubble collapse on living cells.
This paper is focused on the research of airflow generating through the use of high-voltage electrohydrodynamic devices. For this purpose, the authors built several electrohydrodynamic airflow generators with one point electrode and one tube electrode of varying dimensions and compared their efficiency in generating the airflow in order to find an optimal design. The character of the flow was also analyzed with the help of particle image velocimetry, and velocity vector maps and velocity profile were acquired. In addition, a possible practical cooling application was proposed and realized with positive results. Lastly, the products present in the generated airflow were tested for ozone and nitrogen oxides, which could have detrimental effects on human health and material integrity. In both cases, the concentration has been found to be below permissible limits.