Phung Thi Lan Anh

Mrs. Phung Thi Lan Anh

Faculty of Engineering, University of Yamanashi, Kōfu, Yamanashi, Japan
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 May 2019 in Journal of Analytical Methods in Chemistry
Verified
Journal Article
Open access
PDF file
DVDuc Nam Vu
Duc Nam Vu
TNTrung Nguyen-Quang
Trung Nguyen-Quang
TLThuy Le-Minh
Thuy Le-Minh
XNXuyen Nguyen-Thi
Xuyen Nguyen-Thi
TTTri Manh Tran
Tri Manh Tran
DCDinh Binh Chu
Dinh Binh Chu
An ultrahigh-performance liquid chromatography in combination with high-resolution mass spectrometry Thermo Q-Extractive Focus Orbitrap MS has been introduced for analysis of multiclass pesticides in vegetable samples collected in Hanoi, Vietnam. Multiclass pesticides were separated on the Thermo Hypersil Gold PFP column utilizing a gradient of the mobile phase consisting of 5 mM ammonium formate, 0.1% formic acid in deionized water, and methanol. The target analytes were detected in the full-scan mode on Thermo Scientific Q-Exactive Focus Orbitrap MS for quantitation at the optimum operating conditions. These conditions included, but not limit to, the resolution of 70000 at the full width at half maximum in both positive and negative mode, mass range from 80 to 1000 m/z, and optimized parameters for the heated electrospray ionization source. The identification of the analytes in real samples was based on retention times, mass to charge ratios, mass accuracies, and MS/MS spectra at the confirmation mode with the inclusion list of target analytes. The mass accuracies of target analytes were from −4.14 ppm (dinotefuran) to 1.42 ppm (cinosulfuron) in the neat solvent and from −3.91 ppm (spinosad D) to 1.29 ppm (cinosulfuron) in the matrix-matched solution. Target analytes in the vegetable-based matrix were extracted by the QuEChERS method. Some critical parameters of the analytical method such as linearity, repeatability, limit of detection, and limit of quantitation have been evaluated and implemented. Excellent LOD and LOQ of the developed method were achieved at the range of 0.04–0.85 and 0.13–2.9 μg·kg−1, respectively. Intraday and interday repeatability of the analytical signal (peak area, n=6) of the developed method were below 3% and 10%, correspondingly. The matrix effect, extraction recovery, and overall recovery were fully investigated by spiking experiments. Experimental results demonstrated that the ionization suppression or enhancement was the main contribution on the overall recoveries of target analytes. Finally, the in-house validated method was applied to pesticides screening in vegetables samples in local villages in Hanoi, Vietnam. The concentrations of all target analytes were below limit of quantitation and lower than US-FDA or EU maximum residue levels.

26 May 2021 in Journal of Analytical Methods in Chemistry
Verified
Journal Article
Open access
PDF file
DVDuc Nam Vu
Duc Nam Vu
PAPhung Thi Lan Anh
Phung Thi Lan Anh
TLThuy Le-Minh
Thuy Le-Minh
LNLan-Anh Nguyen
Lan-Anh Nguyen
HNHuong Nguyen-Thi
Huong Nguyen-Thi
DCDinh Binh Chu
Dinh Binh Chu
Polycyclic aromatic hydrocarbons (PAHs), the family of organic contaminations, have been shown to have negative effects on human health. However, until now, the comprehension on occurrence, distribution, and risk assessment of human exposure to PAHs has been limited in Vietnam. In this work, a capillary gas chromatography coupled with electron impact ionization tandem mass spectrometry (GC-EI-MS/MS) has been introduced for analysis of 16 PAHs in some particulate matter samples. PAHs have been separated on the TG 5ms capillary gas chromatographic column and detected by tandem mass spectrometry in multiple reaction monitoring mode. The PAHs in the particulate matter (PM 2.5 and PM 10) samples were extracted by ultrasonic-assisted liquid extraction and cleaned up by an acidic silica gel solid phase extraction. The linearity range of all analyzed PAHs was from 5 to 2000ng mL−1 with R2 0.9990. Limit of detection (LOD) of PAHs in particulate matter sample was from 0.001ng m−3 (Br-Naph) to 0.276ng m−3 (Fln). The recovery of PAHs was investigated by international proficiency testing samples. The recoveries of PAHs in proficiency testing sample ranged from 79.3 (Chr) to 109.8 (IcdP). The in-house validated GC-EI-MS/MS method was then applied to analysis of some particulate matter samples that were collected in the Hanoi areas. The total concentrations of PAHs in several brands of samples collected from Hanoi were found in the range of 226.3ng m−3706.43ng m−3. Among the studied compounds, naphthalene was found at high frequency and ranged from 106.5ng m−3 to 631.1ng m−3. The main distribution of the PAHs in particulate matter samples was two-ring and three-ring compounds.

1 July 2021 in Journal of Chromatography A
Verified
Journal Article
Closed access
CVCam Tu Vu
Cam Tu Vu
PLPhuong Thu Le
Phuong Thu Le
DCDinh Binh Chu
Dinh Binh Chu
Bui Van HoiBui Van Hoi
Bui Van Hoi
PAPhung Thi Lan Anh
Phung Thi Lan Anh
PBPhilippe BEHRA
Philippe BEHRA

8 January 2021 in Journal of Analytical Methods in Chemistry
Verified
Journal Article
Open access
PDF file
Bui Van HoiBui Van Hoi
Bui Van Hoi
CVCam-Tu Vu
Cam-Tu Vu
PAPhung Thi Lan Anh
Phung Thi Lan Anh
TNThao Thi Nguyen
Thao Thi Nguyen
PNPhuong Thanh Nguyen
Phuong Thanh Nguyen
DCDinh Binh Chu
Dinh Binh Chu
In this study, an analytical method for the simultaneous determination of 7 major pharmaceutical residues in Vietnam, namely, carbamazepine, ciprofloxacin, ofloxacin, ketoprofen, paracetamol, sulfamethoxazole, and trimethoprim, in surface water and hospital wastewater has been developed. The method includes enrichment and clean-up steps by solid phase extraction using mix-mode cation exchange, followed by identification and quantification using an ultrahigh-performance liquid chromatography and tandem mass spectrometry and employing electrospray ionization (UPLC-ESI-MS/MS). Seven target compounds were separated on the reversed phase column and detected in multiple reaction monitoring (MRM) mode within 6 minutes. The present study also optimized the operating parameters of the mass spectrometer to achieve the highest analytical signals for all target compounds. All characteristic parameters of the analytical method were investigated, including linearity range, limit of detection, limit of quantification, precision, and accuracy. The important parameter in UPLC-ESI-MS/MS, matrix effect, was assessed and implemented via preextraction and postextraction spiking experiments. The overall recoveries of all target compounds were in the ranges from 55 to 109 and 56 to 115 for surface water and hospital wastewater, respectively. Detection limits for surface water and hospital wastewater were 0.0050.015µgL−1 and 0.0140.123µgL−1, respectively. The sensitivity of the developed method was allowed for determination of target compounds at trace level in environmental water samples. The in-house validation of the developed method was performed by spiking experiment in both the surface water and hospital wastewater matrix. The method was then applied to analyze several surface water and hospital wastewater samples taken from West Lake and some hospitals in Vietnam, where the level of these pharmaceutical product residues was still missed. Sulfamethoxazole was present at a high detection frequency in both surface water (33 of analyzed samples) and hospital wastewater (81 of analyzed samples) samples.

1 January 2026 in Journal of Water and Environment Technology
Verified
Journal Article
Open access
PDF file
PAPhung Thi Lan Anh
Phung Thi Lan Anh
MYMasaya Yasuhara
Masaya Yasuhara
NMNoritoshi Morikawa
Noritoshi Morikawa
TNTakashi Nakamura
Takashi Nakamura
In this study, ammonium was separated from water samples using a diffusion technique and oxidized to nitrate. Nitrate was then denitrified and analyzed for isotopic values using isotope ratio mass spectrometry. Each step was carefully examined, particularly oxidation, which was conducted under a near-neutral pH through the addition of a buffer. This precaution was critical because highly acidic or alkaline conditions can lead to nitrogen loss during high-temperature and high-pressure oxidation. The results indicate that the employed ammonium diffusion technique combined with the optimized oxidation process can yield precise and reproducible δ15N values for low-concentration NH4+ water samples. Notably, our method requires only 10 µg of NH4+ for both diffusion and isotope analyses, which is a notable improvement over conventional diffusion techniques, which typically require 50–150 µg. To evaluate potential matrix interferences, we conducted recovery tests by spiking ammonium standards into three different hot spring samples, which often contain low ammonium concentrations and high concentrations of other ions. The results of recovery tests showed robust performance of the proposed method, with recovery rates ranging from 87% to 102%. These results confirm that our method is unaffected by high ion concentrations in complex natural matrices. Additionally, comparison with a previously reported technique revealed no significant difference in the isotope results (paired t-test, p > 0.05). We analyzed several natural hot spring samples across Japan using the proposed method, with the obtained results clarifying the origin of ammonium in the natural hot springs at the investigated locations. Therefore, our analytical method is efficient and highly sensitive for the analysis of ammonium isotopes in environmental water samples with low ammonium concentrations; furthermore, it enables the processing of large numbers of samples in a short time. The δ15NH4+ results contributed to elucidating the NH4+ sources and transport mechanisms at the study locations.

25 June 2026 in Water
Verified
Journal Article
Open access
PDF file
PAPhung Thi Lan Anh
Phung Thi Lan Anh
YIYuki Itoh
Yuki Itoh
LSLee Seongwon
Lee Seongwon
MYMasaya Yasuhara
Masaya Yasuhara
RORyuga Ono
Ryuga Ono
TNTakashi Nakamura
Takashi Nakamura
This study investigates nitrogen sources and biogeochemical pathways in a highly urbanized shallow aquifer in Shinagawa Ward, Tokyo, using an integrated approach combining hydrochemical analysis, multivariate statistics (PCA and K-means cluster analysis), and stable nitrogen isotopes (δ15N-NH4+, δ15N-NO3−, δ15N-DON, and dual δ15N–δ18O-NO3−). K-means clustering (K = 2, silhouette = 0.54) partitioned all 41 samples into a background group (n = 34) and an ion-enriched group (n = 7; wells sbi 1, 2, 3, 4, 5, 13, and 19), with the latter exhibiting hydrochemical signatures consistent with localized sewage leakage. The convergence of hydrochemical, multivariate, and isotopic evidence suggests that soil organic matter may represent the dominant diffuse background source of nitrogen across the study area. DON constitutes the dominant fraction of total dissolved nitrogen (TDN), while the linear correlations between TDN and DON concentrations (r = 0.77, p < 0.001) and between δ15N-TDN and δ15N-DON (r = 0.88, p < 0.001) indicate a common primary source. The dominance of DON combined with the theoretical inverse relationship between δ15N-DON and DON concentration is consistent with active soil DON mineralization, supported by an isotope fractionation factor (ε = −4.4 ± 0.78‰). Dual isotope analysis of NO3− (δ15N–N–δ18O slope = 0.51) points towards denitrification as an ongoing process in the aquifer. Taken together, the isotopic variations among nitrogen species suggest a transformation sequence from soil organic nitrogen → DON → NH4+/NO3− → N2, though each step in this sequence is supported to varying degrees of confidence. These findings highlight the value of δ15N-DON as a tracer for nitrogen source attribution and cycling in urban groundwater systems, and underscore the importance of considering all dissolved nitrogen fractions in contamination assessments.