Bui Van Hoi

Dr. Bui Van Hoi

University of Science and Technology of Hanoi, Hanoi, Hà Nội, Vietnam
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 May 2019 in Journal of Analytical Methods in Chemistry
Verified
Journal Article
Open access
PDF file
DVDuc Nam Vu
Duc Nam Vu
TNTrung Nguyen-Quang
Trung Nguyen-Quang
TLThuy Le-Minh
Thuy Le-Minh
XNXuyen Nguyen-Thi
Xuyen Nguyen-Thi
TTTri Manh Tran
Tri Manh Tran
DCDinh Binh Chu
Dinh Binh Chu
An ultrahigh-performance liquid chromatography in combination with high-resolution mass spectrometry Thermo Q-Extractive Focus Orbitrap MS has been introduced for analysis of multiclass pesticides in vegetable samples collected in Hanoi, Vietnam. Multiclass pesticides were separated on the Thermo Hypersil Gold PFP column utilizing a gradient of the mobile phase consisting of 5 mM ammonium formate, 0.1% formic acid in deionized water, and methanol. The target analytes were detected in the full-scan mode on Thermo Scientific Q-Exactive Focus Orbitrap MS for quantitation at the optimum operating conditions. These conditions included, but not limit to, the resolution of 70000 at the full width at half maximum in both positive and negative mode, mass range from 80 to 1000 m/z, and optimized parameters for the heated electrospray ionization source. The identification of the analytes in real samples was based on retention times, mass to charge ratios, mass accuracies, and MS/MS spectra at the confirmation mode with the inclusion list of target analytes. The mass accuracies of target analytes were from −4.14 ppm (dinotefuran) to 1.42 ppm (cinosulfuron) in the neat solvent and from −3.91 ppm (spinosad D) to 1.29 ppm (cinosulfuron) in the matrix-matched solution. Target analytes in the vegetable-based matrix were extracted by the QuEChERS method. Some critical parameters of the analytical method such as linearity, repeatability, limit of detection, and limit of quantitation have been evaluated and implemented. Excellent LOD and LOQ of the developed method were achieved at the range of 0.04–0.85 and 0.13–2.9 μg·kg−1, respectively. Intraday and interday repeatability of the analytical signal (peak area, n=6) of the developed method were below 3% and 10%, correspondingly. The matrix effect, extraction recovery, and overall recovery were fully investigated by spiking experiments. Experimental results demonstrated that the ionization suppression or enhancement was the main contribution on the overall recoveries of target analytes. Finally, the in-house validated method was applied to pesticides screening in vegetables samples in local villages in Hanoi, Vietnam. The concentrations of all target analytes were below limit of quantitation and lower than US-FDA or EU maximum residue levels.

1 July 2021 in Journal of Chromatography A
Verified
Journal Article
Closed access
CVCam Tu Vu
Cam Tu Vu
PLPhuong Thu Le
Phuong Thu Le
DCDinh Binh Chu
Dinh Binh Chu
Bui Van HoiBui Van Hoi
Bui Van Hoi
PAPhung Thi Lan Anh
Phung Thi Lan Anh
PBPhilippe BEHRA
Philippe BEHRA

3 February 2022 in Sustainable Chemistry and Pharmacy
Verified
Journal Article
Closed access
Bui Van HoiBui Van Hoi
Bui Van Hoi
TVToan Khanh Vu
Toan Khanh Vu
HTHai Tung To
Hai Tung To
NNNobuaki Negishi
Nobuaki Negishi

11 May 2021 in Polymers
Verified
Journal Article
Open access
PDF file
Tien Dat PhamTien Dat Pham
Tien Dat Pham
VBViet Phuong Bui
Viet Phuong Bui
TPThuy Nga Pham
Thuy Nga Pham
TLThi Mai Dung Le
Thi Mai Dung Le
KNKim Thuy Nguyen
Kim Thuy Nguyen
Tien Dat PhamTien Dat Pham
Tien Dat Pham
In the present work, adsorption of anionic azo dye, new coccine (NCC) on silica and silica-gel in an aquatic environment was discovered. Effective conditions such as adsorption time, pH, the influence of dosage on NCC adsorption using strong polycation, poly-diallyl-dimethylammonium chloride (PDADMAC) modified silica (PMS) and PDADMAC modified silica-gel (PMSG) were systematically studied. The removal of NCC using PMS and PMSG were much higher than that using raw silica and silica-gel without PDADMAC in all pH ranges from 3 to 10. The adsorption of NCC onto PMS and PMSG was achieved maxima at the same conditions of contact time 30 min, pH 6. The optimum adsorbent dosages of PMS and PMSG for NCC removal were 10 and 20 mg·mL−1, respectively. Experimental results of NCC adsorption isotherms onto PMS and PMSG at different ionic strength were fitted by Langmuir and Freundlich models. The NCC removal efficiencies using PMS and PMSG were higher than 87%, indicating that PMS and PMSG are novel and reusable adsorbents for removal of anionic dye. Based on adsorption isotherms, and surface group changes after PDADMAC modification and NCC adsorption examined by Fourier transform infrared spectroscopy (FTIR), we demonstrate that electrostatic interaction between positively charged adsorbents’ surfaces and negative sulfonic groups of NCC are the main driving force for anionic azo dye adsorption onto PMS and PMGS adsorbents.

8 January 2021 in Journal of Analytical Methods in Chemistry
Verified
Journal Article
Open access
PDF file
Bui Van HoiBui Van Hoi
Bui Van Hoi
CVCam-Tu Vu
Cam-Tu Vu
PAPhung Thi Lan Anh
Phung Thi Lan Anh
TNThao Thi Nguyen
Thao Thi Nguyen
PNPhuong Thanh Nguyen
Phuong Thanh Nguyen
DCDinh Binh Chu
Dinh Binh Chu
In this study, an analytical method for the simultaneous determination of 7 major pharmaceutical residues in Vietnam, namely, carbamazepine, ciprofloxacin, ofloxacin, ketoprofen, paracetamol, sulfamethoxazole, and trimethoprim, in surface water and hospital wastewater has been developed. The method includes enrichment and clean-up steps by solid phase extraction using mix-mode cation exchange, followed by identification and quantification using an ultrahigh-performance liquid chromatography and tandem mass spectrometry and employing electrospray ionization (UPLC-ESI-MS/MS). Seven target compounds were separated on the reversed phase column and detected in multiple reaction monitoring (MRM) mode within 6 minutes. The present study also optimized the operating parameters of the mass spectrometer to achieve the highest analytical signals for all target compounds. All characteristic parameters of the analytical method were investigated, including linearity range, limit of detection, limit of quantification, precision, and accuracy. The important parameter in UPLC-ESI-MS/MS, matrix effect, was assessed and implemented via preextraction and postextraction spiking experiments. The overall recoveries of all target compounds were in the ranges from 55 to 109 and 56 to 115 for surface water and hospital wastewater, respectively. Detection limits for surface water and hospital wastewater were 0.0050.015µgL−1 and 0.0140.123µgL−1, respectively. The sensitivity of the developed method was allowed for determination of target compounds at trace level in environmental water samples. The in-house validation of the developed method was performed by spiking experiment in both the surface water and hospital wastewater matrix. The method was then applied to analyze several surface water and hospital wastewater samples taken from West Lake and some hospitals in Vietnam, where the level of these pharmaceutical product residues was still missed. Sulfamethoxazole was present at a high detection frequency in both surface water (33 of analyzed samples) and hospital wastewater (81 of analyzed samples) samples.

10 January 2023 in New Journal of Chemistry
Verified
Journal Article
Closed access
PDF file
TPThi Lan Huong Phung
Thi Lan Huong Phung
NVNgoc Phan Vu
Ngoc Phan Vu
TNTuan Anh Nguyen
Tuan Anh Nguyen
NNNgoc Huyen Nguyen
Ngoc Huyen Nguyen
XNXuan Dinh Ngo
Xuan Dinh Ngo
Anh-Tuan LeAnh-Tuan Le
Anh-Tuan Le
In this study, a novel electrochemical sensor for the accurate determination of ofloxacin in a pharmaceutical sample was developed using active-site-rich Cu2MoS4 nanoplates as an excellent electrocatalytic platform.