Pierpaolo Loprieno

Mx. Pierpaolo Loprieno

Department of Earth and Geoenvironmental Sciences, Università degli Studi di Bari, Bari, Puglia, Italy
orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 May 2024 in Ocean Engineering
Verified
Journal Article
Open access
Agostino LauriaAgostino Lauria
Agostino Lauria
Pierpaolo LoprienoPierpaolo Loprieno
Pierpaolo Loprieno
AFA. Francone
A. Francone
ELE. Leone
E. Leone
GTG.R. Tomasicchio
G.R. Tomasicchio

24 August 2024 in Applied Ocean Research
Verified
Journal Article
Open access
Agostino LauriaAgostino Lauria
Agostino Lauria
Pierpaolo LoprienoPierpaolo Loprieno
Pierpaolo Loprieno
FRF. Rizzo
F. Rizzo
ASA. Severini
A. Severini
DFD. Foti
D. Foti
GTG.R. Tomasicchio
G.R. Tomasicchio

24 October 2023 in Energies
Verified
Journal Article
Open access
PDF file
Armando La ScalaArmando La Scala
Armando La Scala
Pierpaolo LoprienoPierpaolo Loprieno
Pierpaolo Loprieno
Dora FotiDora Foti
Dora Foti
MSMassimo La Scala
Massimo La Scala
Due to their reduced emissions and environmental benefits, electric vehicles (EVs) have grown in popularity over the past few years. However, EV fires can be a serious threat to nearby buildings, especially in garages where they are parked and charged. In this work, the behavior of the steel structural components in garages during electric car fires is computationally analyzed. To simulate the heat transmission and the structural reaction of a typical garage exposed to an EV fire, a finite element model was created. A comparison was made between the risk associated with fires generated by internal combustion vehicles (ICEVs) and EVs, with the elaboration of a risk index based on the deflections reached by a steel column under fire conditions. The model predictions are based on experimental data retrieved from various literature investigations, as well as regulatory simplified methods. The study conclusions provide information on how EV and ICEV fires affected garage performance, which may be used to design more resilient and safer buildings. The method represents a good compromise between the typical performance-based approaches and the tabular ones, characterized by good accuracy and low computational burden. This allows the professional to design optimized structures without wasting material and unnecessary coatings with their additional permanent loads, which could be detrimental in the case of other exceptional actions such as earthquakes.

8 June 2024 in Fire
Verified
Journal Article
Open access
PDF file
Armando La ScalaArmando La Scala
Armando La Scala
Pierpaolo LoprienoPierpaolo Loprieno
Pierpaolo Loprieno
Salvador IvorraSalvador Ivorra
Salvador Ivorra
Dora FotiDora Foti
Dora Foti
MSMassimo La Scala
Massimo La Scala
This study analyzes the thermo-mechanical behavior of a brick vault and the effect of a fire on its dynamic characteristics. Based on the results of an experimental test of a real barrel vault with a net span of 161 cm and a net rise of 46.5 cm, an accurate numerical model to simulate the behavior of the brick-and-mortar structure under thermo-mechanical stresses has been implemented. The comparison of the evolution of the displacement in the keystone and the temperatures at various points of the vault allows us to affirm that the adopted micro-modeling approach presents a good accuracy and a feasible computational effort. Finally, this study shows, from a numerical point of view, how the variation in the structure’s eigenfrequencies can be predicted for extreme situations, such as fire damage. This aspect can be critical to develop effective intervention and prevention strategies, which can be useful for the preservation of our valuable cultural and historic resources.

5 December 2025 in Journal of Fluids and Structures
Verified
Journal Article
Open access
Pierpaolo LoprienoPierpaolo Loprieno
Pierpaolo Loprieno
FABIO RIZZOFABIO RIZZO
FABIO RIZZO
ELElisa LEONE
Elisa LEONE
Dora FotiDora Foti
Dora Foti
Giuseppe Roberto TomasicchioGiuseppe Roberto Tomasicchio
Giuseppe Roberto Tomasicchio
Agostino LauriaAgostino Lauria
Agostino Lauria

12 December 2025 in Fluids
Verified
Journal Article
Open access
PDF file
ATAli Tafarojnoruz
Ali Tafarojnoruz
Pierpaolo LoprienoPierpaolo Loprieno
Pierpaolo Loprieno
Attilio Fiorini MorosiniAttilio Fiorini Morosini
Attilio Fiorini Morosini
ELElisa LEONE
Elisa LEONE
Antonio FranconeAntonio Francone
Antonio Francone
Giuseppe Roberto TomasicchioGiuseppe Roberto Tomasicchio
Giuseppe Roberto Tomasicchio
Chlorine contact tanks are crucial for wastewater disinfection, with performance strongly influenced by internal hydraulic characteristics. This study applies Computational Fluid Dynamics (CFD) to analyze and improve the hydraulics of the chlorination contact tank in a Wastewater Treatment Plant in the Southern Italy. A three-dimensional transient CFD model was developed using the Reynolds-Averaged Navier–Stokes (RANS) equations with the Renormalized Group (RNG) turbulence closure. The model simulated flow patterns, tracer transport, and chlorine decay kinetics under the existing configuration and two alternative configurations. Conservative tracer pulse simulations enabled the calculation of Residence Time Distributions (RTDs) and hydraulic efficiency indicators, including the Baffling Factor (θ10), Morrill index (Mo), and Aral–Demirel index (AD). A typical contact tanks geometry exhibits specific hydraulic characteristics, including recirculation behind baffles and stagnant zones in sharp corners, which inevitably affects the contact time. The first alternative, namely featuring rounded corners, moderately reduced dead zones, but did not substantially mitigate recirculation. The second alternative, herein called combining rounded corners with perforated baffle walls, substantially improved hydraulic performance, yielding flow patterns closer to plug-flow. RTD peaks were higher and narrower for the modified designs, and hydraulic indices improved, with Mo decreasing by approximately 5%. These hydraulic enhancements are expected to increase disinfection efficiency by providing more uniform chlorine exposure. The results demonstrate that geometric modifications effectively optimize contact tank hydraulics and highlight the role of CFD as a design and retrofit tool for water and wastewater disinfection systems.