Piotr Miller

Prof. Piotr Miller

Department of Electrical Engineering, Lublin University of Technology, Lublin, Lubelskie, Poland
orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 October 2020 in Energies
Verified
Journal Article
Open access
PDF file
Robert MalkowskiRobert Malkowski
Robert Malkowski
Michał IzdebskiMichał Izdebski
Michał Izdebski
Piotr MillerPiotr Miller
Piotr Miller
The development of renewable energy, including wind farms, photovoltaic farms as well as prosumer installations, and the development of electromobility pose new challenges for network operators. The results of these changes are, among others, the change of network load profiles and load flows determining greater volatility of voltages. Most of the proposed solutions do not assume a change of the transformer regulator algorithm. The possibilities of improving the quality of regulation, which can be found in the literature, most often include various methods of coordination of the operation of the transformer regulator with various devices operating in the Medium-Voltage (MV) network. This coordination can be decentralized or centralized. Unfortunately, the proposed solutions often require costly technical resources and/or large amounts of real-time data monitoring. The goal of the authors was to create an algorithm that extends the functionality of typical transformer control algorithms. The proposed solution allows for reducing the risk of voltage collapse. The performance of the proposed algorithm was validated using multivariate computer simulations and tests with the use of a physical model of the distribution network. The DIgSILENT PowerFactory environment was used to develop the simulation model of the proposed algorithm. Then, tests were conducted on real devices installed in the LINTEˆ2 Laboratory at the Gdańsk University of Technology, Poland. Selected test results are included in this paper. All results have shown that the proposed algorithm makes it possible to increase the reserve of the voltage stability of the node, in which it is applied, thus mitigating the risk of a voltage collapse occurring. The proposed algorithm does not require complex and costly technical solutions. Owing to its simplicity, it has a high potential for practical application, as confirmed by the real-time control experiment in the laboratory.

26 November 2014 in International Transactions on Electrical Energy Systems
Verified
Journal Article
Closed access
PDF file
JMJan Machowski
Jan Machowski
Piotr KacejkoPiotr Kacejko
Piotr Kacejko
SRSylwester Robak
Sylwester Robak
Piotr MillerPiotr Miller
Piotr Miller
MWMarek Wancerz
Marek Wancerz

16 December 2022 in Energies
Verified
Journal Article
Open access
PDF file
Michał IzdebskiMichał Izdebski
Michał Izdebski
Robert MalkowskiRobert Malkowski
Robert Malkowski
Piotr MillerPiotr Miller
Piotr Miller
The subject of the article is issues related to innovative indices for power system stabilizers (PSSs). These new indices will be able to quickly show which PSS (among many other PSSs) is not working properly and that advanced optimization and simulation methods should be used to improve the PSS settings. The authors note the fact that the acceptance requirements for PSSs are different in various power systems. Moreover, the authors pay attention to the fact that transmission system operators (TSOs) often have different PSS requirements (tests) even though they work in the same large power system. The article reviews the requirements for the PSSs used by TSOs of various power systems. The need to supplement the required tests with new qualitative indices is demonstrated. In the paper, new performance indices are proposed to improve the evaluation of the PSS and to check the desired performance of the stabilizer. These indices are derived from the active power frequency response characteristic with PSS and without PSS (PSS ON and PSS OFF). Additionally, the new PSS indices allow the graphical visualization of the properties of all synchronous generators equipped with the PSS in a predefined area on a single 3D graph. Such visualization can be used to quickly detect weak points of the power system.

17 March 2023 in Energies
Verified
Journal Article
Open access
PDF file
Paweł PijarskiPaweł Pijarski
Paweł Pijarski
Piotr KacejkoPiotr Kacejko
Piotr Kacejko
Piotr MillerPiotr Miller
Piotr Miller
Modern power engineering is struggling with various problems that have not been observed before or have occurred very rarely. The main cause of these problems results from the increasing number of connected distributed electricity sources, mainly renewable energy sources (RESs). Therefore, energy generation is becoming more and more diverse, both in terms of technology and location. Grids that have so far worked as receiving networks change their original function and become generation networks. The directions of power flow have changed. In the case of distribution networks, this is manifested by power flows towards transformer stations and further to the network with a higher voltage level. As a result of a large number of RESs, their total share in the total generation increases. This has a significant impact on various aspects of the operation of the power system. Voltage profiles, branch loads, power flows and directions of power flows between areas change. As a result of the random nature of RES generation, there are problems with the quality of electricity, source stability issues, branch overloading, voltage exceedances and power balance. The occurrence of various types of problems requires the use of more and more advanced methods to solve them. This review paper, which is an introduction to the Special Issue Advanced Optimisation and Forecasting Methods in Power Engineering, describes and justifies the need to reach for effective and available mathematical and IT methods that are necessary to deal with the existing threats appearing in the operation of modern power systems. It indicates exemplary, current problems and advanced methods to solve them. This article is an introduction and justification for the use of advanced calculation methods and algorithms. Engineering intuition and experience are often not enough due to the size and complexity of power grid operation. Therefore, it becomes necessary to use methods based on artificial intelligence and other advanced solutions that will facilitate and support decision making in practice.

17 June 2024 in Energies
Verified
Journal Article
Open access
PDF file
Paweł PijarskiPaweł Pijarski
Paweł Pijarski
CSCandra Saigustia
Candra Saigustia
Piotr KacejkoPiotr Kacejko
Piotr Kacejko
ABAdrian Belowski
Adrian Belowski
Piotr MillerPiotr Miller
Piotr Miller
The increasing number of renewable energy sources in power systems contributes to overloads of power lines in emergency situations. Lines made with relatively small cross-section cables, which in the past were designed for an operating temperature of 40 °C, are particularly exposed to overloads. Currently, they constitute the so-called “bottlenecks” in network capacity. This is manifested in the fact that when carrying out expert opinions aimed at examining the impact of a source on the network, computational analyses show overloads of its elements. This article proposes a methodology for eliminating these overloads. It involves the use of two methods at the same time, namely optimal network reconfiguration combined with minimisation of the total power curtailment in RE sources. The search for the optimal network configuration will also allow for minimising power curtailment in renewable energy sources, and thus reduce the costs of this type of operation. With such a tool, network operators will be able to achieve the effect of relieving the line load with the lowest possible cost of redistribution. Based on the IEEE 118 bus test network, calculations were performed that confirmed the effectiveness of the proposed approach. The operation of the proposed methodology is presented with the example of two selected network failure states. The novelty of the proposed solution lies in the simultaneous use of two methods of eliminating line overloads. This streamlines the entire process and improves its effectiveness.

17 November 2024 in Energies
Verified
Journal Article
Open access
PDF file
KJKlara Janiga
Klara Janiga
Piotr MillerPiotr Miller
Piotr Miller
Robert MalkowskiRobert Malkowski
Robert Malkowski
Michał IzdebskiMichał Izdebski
Michał Izdebski
The paper proposes a new local method of controlling the on-load tap changer (OLTC) of a transformer to mitigate negative voltage phenomena in low-voltage (LV) networks with a high penetration of photovoltaic (PV) installations. The essence of the method is the use of the load compensation (LC) function with settings determined via artificial neural network (ANN) algorithms. The proposed method was compared with other selected local methods recommended in European regulations, in particular with those currently required by Polish distribution system operators (DSOs). Comparative studies were performed using the model of the 116-bus IEEE test network, taking into account the unbalance in the network and the voltage variation on the medium voltage (MV) side.