Ching-Ying Cheng

Mr. Ching-Ying Cheng

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 December 2021 in Healthcare
Verified
Journal Article
Open access
PDF file
CCChi-Wu Chang
Chi-Wu Chang
KSKuo-Chen Su
Kuo-Chen Su
FLFang-Chun Lu
Fang-Chun Lu
HCHong-Ming Cheng
Hong-Ming Cheng
CCChing-Ying Cheng
Ching-Ying Cheng
Purpose: With the benefits of advanced medical technology, Taiwan has gradually changed from an aged society to a super-aged society. According to previous studies, the prevalence rate of mild cognitive impairment (MCI) over the age of 60 is 15% to 20%. Therefore, the main purpose of our study was to analyze the correlation of cognitive function with visual function (specifically, binocular vision and visual perception) in Taiwanese volunteers aged 60 years or older. Methods: Thirty-six healthy participants who were not taking psychiatric medications and who had not been diagnosed with any retinal or optic nerve diseases were enrolled. Addenbrooke’s cognitive examination III (ACE-III), binocular visual function, and visual perception evaluation were performed, and the data analyzed statistically by t-test, χ2, linear regression, and MANOVA. Results: Cognitive function was closely correlated with visual function and visual perception; the horizontal adjustment time of binocular eye movement, stereopsis, the motor-free visual perception test-4 (MVPT-4), and peripheral awareness actually displayed higher explanatory power in predicting cognitive function. In addition, various interactive parameters between visual function and visual perception were found to affect specific aspects of ACE-III. Discussion: Our study revealed that there was a close correlation of cognitive function with visual function; as such, it may be possible to predict visual function deficits in patients with mild cognitive impairment.

24 December 2021 in Coatings
Verified
Journal Article
Open access
PDF file
Chuen-Lin TienChuen-Lin Tien
Chuen-Lin Tien
HLHong-Yi Lin
Hong-Yi Lin
KCKuan-Sheng Cheng
Kuan-Sheng Cheng
Chun-Yu ChiangChun-Yu Chiang
Chun-Yu Chiang
CCChing-Ying Cheng
Ching-Ying Cheng
This study presents a multilayer design and fabrication of an optical notch filter for enhancing visual quality. A cost-effective multilayer design of notch filter with low surface roughness and low residual stress is proposed. A 9-layer notch filter composed of SiO2 and Nb2O5 with a central wavelength of 480 nm is prepared by electron beam evaporation combined with ion-assisted deposition. The optical transmittance, residual stress, and surface morphology are measured by a UV/VIS/NIR spectrophotometer, Twyman-Green interferometer and field emission scanning electron microscopy (FE-SEM). The transmittance of the notch filter at the central wavelength is above 15%, and the average transmittance of the transmission band is about 80%. The residual stress of the notch filter is −0.235 GPa, and the root mean square surface roughness is 1.85 nm. For improving the visual quality, a good image contrast can be obtained by observing the microscopic image using the proposed notch filter.

21 April 2022 in Scientific Reports
Verified
Journal Article
Open access
PDF file
SCShyan-Tarng Chen
Shyan-Tarng Chen
HTHsiao-Ching Tung
Hsiao-Ching Tung
YCYan-Ting Chen
Yan-Ting Chen
CTChuen-Lin Tien
Chuen-Lin Tien
CYChih-Wei Yeh
Chih-Wei Yeh
CCChing-Ying Cheng
Ching-Ying Cheng
Theoretically, contact lenses change the accommodation and vergence demands of the eyes and directly or indirectly influence binocular vision. The purpose of this study was to investigate the influence of different optical designs of contact lenses on binocular vision and visual behavior among young adults. In this randomized, single-blinded experimental study, visual behavioral performance (VBP) and Ocular Surface Disease Index questionnaires were used for preliminary screening. Nineteen myopic subjects aged 20–26 years (21.59 ± 1.40 years) participated in the study. Baseline values for subjective refraction and binocular visual functions were evaluated. All the subjects were randomly grouped to wear different optical designs of single-vision, progressive, and bifocal contact lenses. Eye examinations were performed on the first day (CL baseline), 2nd week, and 4th week of wearing the lenses. In addition, subjects completed the VBP and visual quality questionnaire again at the end of the examination. Single-vision contact lenses (Lens 1) increased accommodative lag, negative relative accommodation, and distant and near vergence; however, vergence facilities, accommodative facilities, heterophoria, and the comfort and posture balance dimensions in the VBP questionnaire were improved. Progressive contact lenses (Lens 2) reduced the lag of accommodation and near vergence; in addition, vergence facilities and accommodative facilities were also improved. Bifocal contact lenses (Lens 3) affected negative and positive relative accommodation, but vergence facilities and accommodative facilities also progressed. Furthermore, both progressive (Lens 2) and bifocal (Lens 3) contact lenses enhanced overall visual behavioral performance. In terms of visual quality, single-vision contact lenses (Lens 1) were the most comfortable, progressive and bifocal contact lenses reduced distant visual acuity and stability, progressive contact lenses (Lens 2) had more complaints about halos at night, and bifocal contact lens (Lens 3) users were more likely to have double vision. Compared with single-vision contact lenses, progressive and bifocal contact lenses relaxed accommodation, reduced the lag of accommodation, and improved visual behavioral performance. Although the vergence function showed a significant change, it did not show worse trends when wearing contact lenses. Contact lenses with different optical designs have a great influence on binocular vision and visual behavioral performance.

30 April 2023 in Coatings
Verified
Journal Article
Open access
PDF file
Chuen-Lin TienChuen-Lin Tien
Chuen-Lin Tien
SSShu-Hui Su
Shu-Hui Su
CCChing-Ying Cheng
Ching-Ying Cheng
YCYuan-Ming Chang
Yuan-Ming Chang
DMDong-Han(莫東翰博士) Mo
Dong-Han(莫東翰博士) Mo
We propose two single-wavelength notch filters and one dual-wavelength (480 and 620 nm) notch filter to enhance image contrast. The stack structure of the notch filters was designed as (Ta2O5/SiO2)4Ta2O5 in Essential Macleod thin film simulation software. Dual-electron-beam evaporation with ion beam-assisted deposition was used to prepare optical interference filters with different center wavelengths. A multilayer notch filter with a center wavelength of 620 nm was deposited on the front surface of the glass, and then a notch filter with a center wavelength of 480 nm was coated on the rear surface of the same glass. The proposed dual-wavelength (480 and 620 nm) notch filter is a combination of two single-wavelength notch filters coated on a double-sided glass substrate to compensate for residual stress. The transmittance, residual stress, and surface roughness of the proposed notch filter were evaluated using different measuring instruments. The experimental results show that the residual stress of the dual-wavelength notch filter could be reduced to 10.8 MPa by using a double-sided coating technique. The root-mean-square (RMS) surface roughness of the notch filters was measured by using a Linnik microscopic interferometer. The RMS surface roughness was 1.80 for the 620 nm notch filter and 2.09 for the 480 nm notch filter. The image contrast obtained with the three different notch filters was measured using an optical microscope and a CMOS camera. The contrast value could be increased from 0.328 (without a filter) to 0.696 (dual-wavelength notch filter).

23 April 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
LTLung-Hui Tsai
Lung-Hui Tsai
CCChing-Chung Chen
Ching-Chung Chen
CLChien-Ju Lin
Chien-Ju Lin
SLSheng-Pei Lin
Sheng-Pei Lin
CCChing-Ying Cheng
Ching-Ying Cheng
HHHSIEH HSI-PAO
HSIEH HSI-PAO
Purpose: According to previous studies, the prevalence rate of cataracts has increased in recent years. This study aims to investigate and analyze the risk factors of early-onset cataracts in Taiwan. Methods: A total of 71 subjects aged between 20 and 55 were diagnosed with cataracts in a medical center. Participants were divided into three groups: control, early-onset cataract (EOC), and combined (EOC combined with dry eye) groups. Eye examinations including autorefraction, best-corrected visual acuity (BCVA), subjective refraction, axial length, fundus, slit lamp, and reactive oxygen species (ROS, including total antioxidative capacity, TAC; C-reactive protein, CRP; and glutathione peroxidase, GPx) were performed. In addition, a questionnaire on patient information, history, habits, family history, and Depression Anxiety Stress Scales (DASS) was completed before the examination. Results: 27 non-EOC (control group), 20 EOC, and 24 combined patients participated in the study. Compared with the control group, Body Mass Index (BMI), gender, educational level, hypertension, diabetes, hyperlipidemia, chronic pain, and body-related diseases were significantly different between the three groups. Family history was also significantly different: family heart disease, hypertension, asthma, allergies, stroke, and immune system were also significantly different. In addition, subjects who took hypertensive drugs, antihistamines, and other medications were also significantly different. Statistical analysis indicated that best corrective visual acuity and the spherical equivalent were significantly different between the three groups. Similar results were found in CRP blood analysis. Discussion and Conclusion: According to the results, EOC may result from systemic diseases. The risk corresponded to an increase in ROS blood analysis. Furthermore, eye drops and medicine intake significantly influenced EOC patients. To prevent or defer early-onset cataracts, monitoring physical health, CRP, and GPx analysis may be worth considering in the future.

9 November 2023 in Scientific Reports
Verified
Journal Article
Open access
PDF file
CHChing-Jen Hsiao
Ching-Jen Hsiao
HTHsiao-Ching Tung
Hsiao-Ching Tung
CTChuen‐Lin Tien
Chuen‐Lin Tien
YCYu-Wen Chang
Yu-Wen Chang
CCChing-Ying Cheng
Ching-Ying Cheng
This study investigated the influence of large-diameter multifocal contact lenses on the ocular surface, visual quality, and visual function for presbyopic adults with dry eye syndromes. The study enrolled 40–55-year-old adults with presbyopia and dry eye syndromes (DES). The subjects were randomly assigned to three groups wearing different designs of contact lenses (Proclear, SMR, and Optimum) for 6–8 h a day for two weeks. Ocular surface health, tear quality, visual quality, and visual function were measured before and after lens wear. No significant difference was observed across all three groups for the amount of conjunctival redness, blink frequency (lens on), and stereopsis vision before and after wearing. Although there seemed to be a significant declining trend for corneal staining and limbal redness, non-invasive tear break-up time (TBUT), and lipid layer thickness while lens wear, the measured values were all within the normal range. Vice-versa after lens removal, results also showed significant improvement on lipid layer thickness, blink frequency (lens off), and contact TBUT. A significant improvement was observed in the modulation transfer function (MTF) of the total area ratio after wearing contact lenses. In contrast, the MTF of the high-order aberration area ratio resulting from lens wear was lower than that of the baseline measurement. There are also significant improvements observed for SMR and Optimum regarding near visual acuity, near point of accommodation, and the subjective questionnaire (OSDI and VBP) scores. Although it is difficult to avoid a specific negative impact on the ocular surface and tear film, visual function and visual quality can still be positively improved, especially shown on larger diameter and distance-center designed multifocal contact lenses.