Alexandru Popa

Dr. Alexandru Popa

Department of Gastroenterology and Hepatology, Gastroenterology and Hepatology Research Center, ”Victor Babeș” University of Medicine and Pharmacy, Timișoara, Romania
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 April 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
Alexandru PopaAlexandru Popa
Alexandru Popa
FBFelix Bende
Felix Bende
Roxana SirliRoxana Sirli
Roxana Sirli
Alina PopescuAlina Popescu
Alina Popescu
VBVictor Bâldea
Victor Bâldea
Ioan SporeaIoan Sporea
Ioan Sporea
Non-alcoholic fatty liver disease (NAFLD) is the most common chronic liver disease worldwide. This study aimed to evaluate the performance of four ultrasound-based techniques for the non-invasive multiparametric (MPUS) assessment of liver fibrosis (LF), steatosis (HS), and inflammation in patients with NAFLD. We included 215 consecutive adult patients with NAFLD (mean age: 54.9 ± 11.7; 54.5% were male), in whom LF, HS, and viscosity were evaluated in the same session using four new ultrasound-based techniques embedded on the Aixplorer MACH 30 system: ShearWave Elastography (2D-SWE.PLUS), Sound Speed Plane-wave UltraSound (SSp.PLUS), Attenuation Plane-wave UltraSound (Att.PLUS), and Viscosity Plane-wave UltraSound (Vi.PLUS). Transient Elastography (TE) with Controlled Attenuation Parameter (CAP) (FibroScan) were considered as control. All elastographic measurements were performed according to guidelines. Valid liver stiffness measurements (LSM) were obtained in 98.6% of patients by TE, in 95.8% of patients by 2D-SWE.PLUS/Vi.PLUS, and in 98.1% of patients by Att.PLUS/SSp.PLUS, respectively. Therefore, 204 subjects were included in the final analysis. A strong correlation between LSMs by 2D-SWE.PLUS and TE (r = 0.89) was found. The best 2D-SWE.PLUS cut-off value for the presence of significant fibrosis (F ≥ 2) was 7 kPa. Regarding steatosis, SSp.PLUS correlated better than Att.PLUS with CAP values: (r = −0.74) vs. (r = 0.45). The best SSp.PLUS cut-off value for predicting the presence of significant steatosis was 1524 m/s. The multivariate regression analysis showed that Vi.PLUS values were associated with BMI and LSM by 2D-SWE.PLUS. In conclusion, MPUS was useful for assessing fibrosis, steatosis, and inflammation in a single examination in patients with NAFLD.

1 July 2021 in Ultrasound in Medicine & Biology
Verified
Journal Article
Closed access
Alexandru PopaAlexandru Popa
Alexandru Popa
RȘRoxana Șirli
Roxana Șirli
APAlina Popescu
Alina Popescu
VBVictor Bâldea
Victor Bâldea
RLRaluca Lupusoru
Raluca Lupusoru
ISIoan Sporea
Ioan Sporea

17 March 2023 in Biomedicines
Verified
Journal Article
Open access
PDF file
Dana StoianDana Stoian
Dana Stoian
ABAndreea Borlea
Andreea Borlea
Ioan SporeaIoan Sporea
Ioan Sporea
Alexandru PopaAlexandru Popa
Alexandru Popa
MLMoisa-Luca Luciana
Moisa-Luca Luciana
Alina PopescuAlina Popescu
Alina Popescu
The estimation of viscosity by measuring the shear-wave dispersion (SWD) using ultrasound 2D shear-wave elastography (SWE) is becoming more and more popular. Recent research suggests that SWD can be used in addition to 2D-SWE (shear-wave speed) to diagnose diffuse liver disease. Viscosity was studied for the assessment of normal thyroid tissue. This study aims to evaluate the use of viscosity measurements in patients with chronic autoimmune thyroiditis using the SuperSonic MACH®30 ultrasound machine (Hologic SuperSonic Imagine, Aix-en-Provence, France) which provides the Vi PLUS mode for viscosity and the 2D SWE PLUS mode for shear-wave speed measurements. Valid measurements were obtained in 308 cases, 153 with chronic autoimmune thyroiditis (CAT) and 155 with no thyroid pathology (95.95% feasibility of the methods). The differences between the healthy group and the CAT group were statistically significant both for Vi PLUS (2.5 ± 0.4 vs. 2.8 ± 0.5, p < 0.0001) and for 2D-SWE PLUS (13.5 ± 3.3 vs. 23.1 ± 8.3, p < 0.0001). The diagnostic performance was poor for Vi PLUS alone (AUC = 0.69; cut-off > 2.5 Pa·s, se = 68.6%; sp = 64.52%) and good for 2D-SWE PLUS alone (AUC = 0.861; cut-off > 18.4 kPa, se = 69.9%; sp = 92.2%). Vi PLUS correlated with 2D-SWE PLUS, with the presence of CAT, the thyroid volume, levothyroxine replacement therapy and age. Statistically significant differences were found between the CAT subgroup receiving thyroid replacement therapy and the subgroup without therapy: 24.74 ± 8.33 vs. 21.93 ± 8.12 kPa for 2D-SWE (p = 0.0380) and 3 ± 0.5 vs. 2.7 ± 0.4 Pa·s for Vi PLUS (p = 0.0193). Elastography-based methods improve the classic ultrasound evaluation: 2D-SWE PLUS performed somewhat better in distinguishing CAT from normal thyroid tissue, while Vi PLUS made a slightly better assessment regarding the functional status.

13 June 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
Alexandru PopaAlexandru Popa
Alexandru Popa
Ioan SporeaIoan Sporea
Ioan Sporea
FBFelix Bende
Felix Bende
Alina PopescuAlina Popescu
Alina Popescu
FRFofiu Renata
Fofiu Renata
Roxana SirliRoxana Sirli
Roxana Sirli
Liver fibrosis is the most significant prognostic factor in chronic liver disease (CLD). Clinical practice guidelines recommend the use of non-invasive techniques, such as two-dimensional shear-wave elastography (2D-SWE), to assess liver stiffness as a marker of fibrosis. Several other factors influence liver stiffness in addition to liver fibrosis. It is presumed that changes due to necro-inflammation modify the propagation of shear waves (dispersion). Therefore, new imaging techniques that investigate the dispersion properties of shear waves have been developed, which can serve as an indirect method of measuring liver viscosity (Vi PLUS). Defining the reference values in healthy subjects among different age groups and genders and analyzing the factors that influence these values is essential. However, published data on liver viscosity are still limited. This is the first study that aimed to assess the normal range of liver viscosity values in subjects with healthy livers and analyze the factors that influence them. One hundred and thirty-one consecutive subjects with healthy livers were enrolled in this prospective study. The results showed that Vi PLUS is a highly feasible method. Liver stiffness, age and BMI influenced the liver viscosity values. The mean liver viscosity by Vi PLUS in subjects with healthy livers was 1.59 Pa·s.

8 November 2022 in Biomedicines
Verified
Journal Article
Open access
PDF file
FMFelix-Mihai Maralescu
Felix-Mihai Maralescu
FBFelix Bende
Felix Bende
Ioan SporeaIoan Sporea
Ioan Sporea
Alina PopescuAlina Popescu
Alina Popescu
Roxana SirliRoxana Sirli
Roxana Sirli
FBFlaviu Bob
Flaviu Bob
Introduction: There is currently a lack of published data on kidney elasticity and viscosity. Non-invasive techniques, such as two-dimensional shear-wave elastography (2D-SWE PLUS) and viscosity plane-wave ultrasound (Vi PLUS), have surfaced as new detection methods, which, thanks to efficient processing software, are expected to improve renal stiffness and viscosity measurements. This study aims to be the first one to assess the normal range values in normal renal function subjects and to investigate the factors that impact them. Methods: We conducted a cross-sectional study employing 50 participants (29 women and 21 men) with a mean age of 42.22 ± 13.17, a mean estimated glomerular filtration rate (eGFR) of 97.12 ± 11 mL/min/1.73 m2, a mean kidney length of 10.16 ± 0.66 cm, and a mean body mass index (BMI) of 24.24 ± 3.98. With a C6-1X convex transducer and the Ultra-FastTM software available on the Hologic Aixplorer Mach 30 ultrasound system, we acquired five measurements of renal cortical stiffness and viscosity (achieved from five distinct images in the middle part of the subcapsular cortex) from each kidney. The ten measurements’ median values correlated with the participant’s demographical, biological, and clinical parameters. Results: The mean kidney elasticity was 31.88 ± 2.89 kiloPascal (kPa), and the mean viscosity was 2.44 ± 0.57 Pascal.second (Pa.s) for a mean measurement depth 4.58 ± 1.02 cm. Renal stiffness seemed to be influenced by age (r = −0.7047, p < 0.0001), the measurement depth (r = −0.3776, p = 0.0075), and eGFR (r = 0.6101, p < 0.0001) but not by BMI (r = −0.2150, p = 0.1338), while viscosity appeared to be impacted by age (r = −0.4251, p = 0.0021), eGFR (r = 0.4057, p = 0.0038), the measurement depth (r = −0.4642, p = 0.0008), and BMI (r = −0.3676, p = 0.0086). The results of the one-way ANOVA used to test the differences in the variables among the three age sub-groups are statistically significant for both 2D-SWE PLUS (p < 0.001) and Vi PLUS (p = 0.015). The method found good intra-operator reproducibility for the 2D-SWE PLUS measurements, with an ICC of 0.8365 and a 95% CI of 0.7512 to 0.8990, and for the Vi PLUS measurements, with an ICC of 0.9 and a 95% CI of 0.8515 to 0.9397. Conclusions: Renal stiffness and viscosity screening may become an efficacious, low-cost way to gather supplemental diagnostic data from patients with chronic kidney disease (CKD). The findings demonstrate that these non-invasive methods are highly feasible and not influenced by gender and that their values correlate with renal function and decrease with age progression. Nevertheless, more research is required to ascertain their place in clinical practice.

9 September 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
Dana StoianDana Stoian
Dana Stoian
MLMoisa-Luca Luciana
Moisa-Luca Luciana
LTLaura Taban
Laura Taban
Ioan SporeaIoan Sporea
Ioan Sporea
Alexandru PopaAlexandru Popa
Alexandru Popa
ABAndreea Borlea
Andreea Borlea
Shear-wave elastography (SWE) is widely used in thyroid evaluation, but multiple factors influence thyroid stiffness. Estimating tissue viscosity may enhance the ultrasound diagnosis of thyroid diseases, along with the ultrasound (US) and the SWE assessment. In order to be able to detect diffuse thyroid disease by viscosity measurements, it is essential to firstly define the normal values of thyroid viscosity in healthy subjects. Currently there are no published data on thyroid viscosity measurements. This first prospective study aimed to determine the normal range of thyroid viscosity values in a cohort of healthy thyroids, as well as to determine the factors that may influence them. One hundred and twenty-one consecutive subjects without thyroid pathology were evaluated in the study by means of conventional ultrasound, two-dimensional SWE (2D SWE PLUS) and viscosity plane-wave ultrasound (ViPLUS) embedded in the Supersonic MACH® 30 ultrasound system. Five valid tissue viscosity measurements were obtained for each thyroid lobe in every patient and the median values were analyzed and correlated with the biological and demographic parameters of each patient. Our results reveal that ViPLUS is a highly feasible and reproducible technique for thyroid evaluation. Thyroid stiffness, age, gender, BMI and depth of measurements did not influence the thyroid viscosity values. The mean thyroid viscosity by ViPLUS for normal thyroid tissue was of 2.42 ± 0.41 Pa·s. Viscosity assessment by Supersonic ViPLUS is an innovative, non-invasive technique that has proven to be useful for thyroid US evaluation and remains to demonstrate its effectiveness in identifying patients with thyroid disease.