Zuzana Psenakova

Dr. Zuzana Psenakova

University of Žilina, Žilina, Žilinský, Slovakia

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 August 2022 in Sensors
Verified
Journal Article
Open access
PDF file
ZPZuzana Psenakova
Zuzana Psenakova
MSMaros Smondrk
Maros Smondrk
JBJan Barabas
Jan Barabas
MBMariana Beňová
Mariana Beňová
Rafał BrociekRafał Brociek
Rafał Brociek
Grazia Lo SciutoGrazia Lo Sciuto
Grazia Lo Sciuto
The presented study discusses the possible disturbing effects of the electromagnetic field of antennas used in mobile phones or WiFi technologies on the pacemaker in the patient’s body. This study aims to obtain information on how the thickness of skin layers (such as the thickness of the hypodermis) can affect the activity of a pacemaker exposed to a high-frequency electromagnetic field. This study describes the computational mathematical analysis and modeling of the heart pacemaker inserted under the skin exposed to various electromagnetic field sources, such as a PIFA antenna and a tuned dipole antenna. The finite integration technique (FIT) for a pacemaker model was implemented within the commercially available CST Microwave simulation software studio. Likewise, the equations that describe the mathematical relationship between the subcutaneous layer thickness and electric field according to different exposures of a tuned dipole and a PIFA antenna are used and applied for training a neural network. The main output of this study is the creation of a mathematical model and a multilayer feedforward neural network, which can show the dependence of the thickness of the hypodermis on the size of the electromagnetic field, from the simulated data from CST Studio.

1 September 2017
Verified
Conference Paper
Closed access
MSMaros Smondrk
Maros Smondrk
MBMariana Beňová
Mariana Beňová
ZPZuzana Psenakova
Zuzana Psenakova
The proposed paper deals with simulation and analysis of the radiofrequency field inside the multilayered human tissue model comprising a superficial metallic implant. The research was carried out using electromagnetic modeling based on the Finite Integration method and analysis was performed in terms of computing electric field distributions and spatial-averaged SAR distributions. The main objective was to compare levels of absorbed electromagnetic energy with and without metallic implant, depending on the fat layer thickness. The focus was on far-field exposure modeled by linearly polarized electromagnetic plane waves. The results have shown that the presence of a metallic implant caused higher SAR distribution, as well as variability with respect to the fat layer thickness. However, dosimetric limits were not exceed in all considered exposure scenarios.

15 August 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
FBFrederika Bačová
Frederika Bačová
MBMariana Beňová
Mariana Beňová
ZPZuzana Psenakova
Zuzana Psenakova
MSMilan Smetana
Milan Smetana
MPMiroslav PACEK
Miroslav PACEK
JOJan Ochodnicky
Jan Ochodnicky
This article investigates the effects of electromagnetic field (EMF) from mobile phones on human tissues and implanted medical devices. The intensity of the electric field (E) is evaluated based on simulations and measurements of various exposure scenarios. An area of interest is the case of a person with an implanted device (heart pacemaker) who may be affected by this exposure. Due to the rapid development of communication technologies and the growing awareness of the potential health risks of radio frequency (RF) EMF, the International Commission on Non-Ionizing Radiation Protection (ICNIRP) has established exposure limits within the European Union. Our study models and analyses EMF values in human tissues in an ideal environment, in a situation where a person uses a mobile phone in the DCS (Digital Cellular System) band, including the case of a person with an implanted pacemaker. Pilot simulations were verified by experimental measurements. Based on them, specific human models with the best matching results were selected for modelling other possible interactions of exogenous EMF and cardiac pacemaker in the same situations and locations.

17 May 2025 in Electrical Engineering
Verified
Journal Article
Open access
PDF file
FBFrederika Bačová
Frederika Bačová
MBMariana Beňová
Mariana Beňová
ZPZuzana Psenakova
Zuzana Psenakova
VWVeronika Wohlmuthová
Veronika Wohlmuthová
The influence of radiofrequency (RF) electromagnetic fields (EMF) on human occupants within shielded regions of railway compartment is being investigated in this study using the CST Studio Suite program. The simulations investigate the specific absorption rate (SAR) for 1 g and 10 g of human tissue in nine carefully selected settings, with a focus on a Planar Inverted-F Antenna (PIFA) operating at 1800 MHz. Within the limited space of the railway wagon compartment, these positions symbolize various spots of the possible human body occurrence. Three human models were analyzed: a multilayer adult model, a child complex model, and an adult female complex model. For the multilayer model, the highest SAR values were 2.41 W/kg for the 1 g method and 0.93 W/kg for the 10 g method. For the child model, SAR values ranged from 1.99 to 2.12 W/kg (1 g method) and from 1.38 to 1.47 W/kg (10 g method), with the highest observed near metallic walls. The adult female model demonstrated distinct SAR patterns, with maximum values of 1.63 W/kg (1 g method) and 0.76 W/kg (10 g method) observed in central compartment positions. Results indicate significant variability in SAR values depending on position and anatomical model, emphasizing the influence of reflection and absorption effects within confined metallic environments.

11 September 2022
Verified
Conference Paper
Closed access
DGDaniela Gombarska
Daniela Gombarska
ZPZuzana Psenakova
Zuzana Psenakova
AGAndrea Gajdosova
Andrea Gajdosova
The article focuses on developing a simulation model of the realistic shape human head phantom used for investigating the influence of the electromagnetic field on the human body and the processes taking place in it. The introductory part is reserved to describing the modelled antennas and the human head phantom itself. The results of numerical simulations and measurements on a realistic human head phantom are compared.

1 September 2020
Verified
Conference Paper
Closed access
DGDaniela Gombarska
Daniela Gombarska
ZPZuzana Psenakova
Zuzana Psenakova
Evaluation of electromagnetic field (EMF) inside motorcycle helmet with Bluetooth communicator is the main goal of the paper. Measurement was made under the laboratory condition using two helmets with integrated Bluetooth communicator set in intercom mode for three cases, helmet distance set to 500mm without communication, same distance with communication and for distance of 2500mm with ongoing communication. As measurement setup BK PRECISION 2650A spectral analyser together with Rohde & Schwarz antennas were used.