The constant development and miniaturization of MEMS sensors invariably provides new possibilities for their use in health-related and medical applications. The application of MEMS devices in posturographic systems allows faster diagnosis and significantly facilitates the work of medical staff. MEMS accelerometers constitute a vital part of such systems, particularly those intended for monitoring patients with imbalance disorders. The correct design of such sensors is crucial for gathering data about patient movement and ensuring the good overall performance of the entire system. This paper presents the design and measurements of a three-axis accelerometer dedicated for use in a device which tracks patient movement. Its main focus is the characterization of the sensor, comparing different designs and evaluating the impact of the packaging and readout circuit integration on sensor operation. Extensive testing and measurements confirm that the designed accelerometer works correctly and allows identifying the best design in terms of sensitivity/stability. Moreover, the response of the proposed sensor as a function of the applied acceleration demonstrates very good linearity only if the readout circuit is integrated in the same package as the MEMS sensor.
1 November 2018 in Computer Physics Communications
The European Spallation Source (ESS), currently under construction in Lund, Sweden, will be a neutron source based on a partly superconducting linac. The ESS linac will be accelerating protons to 2 GeV with a peak current of 62.5 mA and ultimately delivering a 5 MW beam to a rotating tungsten target for neutron production. For a successful tuning and operation of a linac, a beam loss monitoring (BLM) system is required. BLM systems are designed to protect the machine from beam-induced damage and unnecessary activation of the components. This paper focuses on one of the BLM systems to be deployed at the ESS linac, namely the neutron sensitive BLM (nBLM). An overview of the ESS nBLM system design will be presented. In addition to this, results of the tests performed with the full nBLM data acquisition chain will be discussed. These tests represent the first evaluation of the system prototype in a realistic environment. They served as an input to initial study of the procedure for neutron detection algorithm configuration discussed in this contribution as well.
ARUZ is a large scale, massively parallel, FPGA-based reconfigurable computational system dedicated primarily to molecular analysis. This paper presents a methodology for ARUZ firmware development that simplifies the process, offers low-level optimization, and facilitates verification. According to this methodology, firstly an expanded, generic, all-in-one VHDL description of variable Processing Elements (PEs) is developed manually. GCC preprocessing is then used to extract only the desired target functionality. A dedicated software instantiates and connects PEs in form of a scalable network, divides it into subsets for chips and generates its HDL description. As a result, individual HDL-coded specification, optimized for certain analysis, is provided for the synthesis tool. Code reuse and automated generation of up to 81% of the code economizes the workload. Using well-optimized VHDL for core description rather than High Level Synthesis eliminates unnecessary overhead. The PE network can be scaled inversely proportional to PEs complexity, in order to efficiently utilize available resources. Moreover, downscaling the problem makes verification during HDL simulations and testing the prototype systems easier.
11 November 2022 in Computer Physics Communications