Rajiv Ranjan Singh

Dr. Rajiv Ranjan Singh

Computer Science, Glasgow Caledonian University, Glasgow, Glasgow City, UK
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 August 2025 in Computers
Verified
Journal Article
Open access
PDF file
JAJoel Anyam
Joel Anyam
Rajiv Ranjan SinghRajiv Ranjan Singh
Rajiv Ranjan Singh
Hadi LarijaniHadi Larijani
Hadi Larijani
APAnand Philip
Anand Philip
With the rise in cloud computing and virtualisation, secure and efficient VPN solutions are essential for network connectivity. We present a systematic performance comparison of OpenVPN (v2.6.12) and WireGuard (v1.0.20210914) across Azure and VMware environments, evaluating throughput, latency, jitter, packet loss, and resource utilisation. Testing revealed that the protocol performance is highly context dependent. In VMware environments, WireGuard demonstrated a superior TCP throughput (210.64 Mbps vs. 110.34 Mbps) and lower packet loss (12.35% vs. 47.01%). In Azure environments, both protocols achieved a similar baseline throughput (~280–290 Mbps), though OpenVPN performed better under high-latency conditions (120 Mbps vs. 60 Mbps). Resource utilisation showed minimal differences, with WireGuard maintaining slightly better memory efficiency. Security Efficiency Index calculations revealed environment-specific trade-offs: WireGuard showed marginal advantages in Azure, while OpenVPN demonstrated better throughput efficiency in VMware, though WireGuard remained superior for latency-sensitive applications. Our findings indicate protocol selection should be guided by deployment environment and application requirements rather than general superiority claims.

16 November 2023 in SN Computer Science
Verified
Journal Article
Open access
PDF file
AKAjay Kumar
Ajay Kumar
Rajiv Ranjan SinghRajiv Ranjan Singh
Rajiv Ranjan Singh
Indranath ChatterjeeIndranath Chatterjee
Indranath Chatterjee
NSNikita Sharma
Nikita Sharma
VRVaishali Rana
Vaishali Rana
Financially incentivizing health-related behaviors can improve health record outcomes and reduce healthcare costs. Blockchain and IoT technologies can be used to develop safe and transparent incentive schemes in healthcare. IoT devices, such as body sensor networks and wearable sensors, etc. connect the physical and digital world making it easier to collect useful health-related data for further analysis. There are, however, many security and privacy issues with the use of IoT. Some of these IoT security issues can be alleviated using Blockchain technology. Incorporating neuroadaptive technology can result in more personalized and effective therapies using machine learning algorithms and real-time feedback. The research investigates the possibilities of neuroadaptive incentivization in healthcare using Blockchain and IoT on patient health records. The core idea is to incentivize patients to keep their health parameters within standard range thereby reducing the load on healthcare system. In summary, we have presented a proof of concept for neuroadaptive incentivization in healthcare using Blockchain and IoT and discuss various applications and implementation challenges.

16 September 2020
Verified
Book Chapter
Closed access
PDF file
Rajiv Ranjan SinghRajiv Ranjan Singh
Rajiv Ranjan Singh
JMJosé Moreira
José Moreira
TCTom Chothia
Tom Chothia
MRMark D. Ryan
Mark D. Ryan

10 November 2025 in Sensors
Verified
Journal Article
Open access
PDF file
PAPeter Ameh Akor
Peter Ameh Akor
EGEnemali Godwin
Enemali Godwin
MUMuhammad Usman
Muhammad Usman
Rajiv Ranjan SinghRajiv Ranjan Singh
Rajiv Ranjan Singh
Hadi LarijaniHadi Larijani
Hadi Larijani
Epilepsy affects over 50 million people globally, with accurate seizure type classification directly influencing treatment selection as different seizure types respond to specific antiepileptic medications. Manual electroencephalogram (EEG) interpretation remains time-intensive and requires specialized expertise, creating clinical workflow bottlenecks. This work presents EEG-ARCNet, an attention-residual convolutional network integrating residual connections with channel attention mechanisms to extract discriminative temporal and spectral features from multi-channel EEG recordings. The model combines nine statistical temporal features with five frequency-band power measures through Welch’s spectral decomposition, processed through attention-enhanced convolutional pathways. Evaluated on the Temple University Hospital Seizure Corpus, EEG-ARCNet achieved 99.65% accuracy with 99.59% macro-averaged F1-score across five seizure types (absence, focal non-specific, simple partial, tonic-clonic, and tonic). To validate practical deployment, the model was implemented on Raspberry Pi 4, achieving a 2.06 ms average inference time per 10 s segment with 35.4% CPU utilization and 499.4 MB memory consumption. The combination of high classification accuracy and efficient edge deployment demonstrates technical feasibility for resource-constrained seizure-monitoring applications.

24 June 2025 in Information
Verified
Journal Article
Open access
PDF file
PAPeter Ameh Akor
Peter Ameh Akor
EGEnemali Godwin
Enemali Godwin
UMUsman Muhammad
Usman Muhammad
Rajiv Ranjan SinghRajiv Ranjan Singh
Rajiv Ranjan Singh
Hadi LarijaniHadi Larijani
Hadi Larijani
Epileptic seizure detection and classification from EEG recordings faces significant challenges due to extreme class imbalance. Analysis of the Temple University Hospital Seizure (TUSZ) dataset reveals imbalance ratios of 150:1 between common and rare seizure types, with high temporal heterogeneity (seizure durations of 1–1638 s). We propose a cascaded deep learning architecture with two specialized CNNs: a binary detector followed by a multi-class classifier. This approach decomposes the classification problem, reducing the maximum imbalance from 150:1 to manageable levels (9:1 binary, 5:1 type). The architecture implements a high-confidence filtering mechanism (threshold = 0.9), creating a 99.5% pure dataset for type classification, dynamic class-weighted optimization proportional to inverse class frequencies, and information flow refinement through progressive stages. Loss dynamics analysis reveals that our weighting scheme strategically redistributes optimization attention, reducing variance by 90.7% for majority classes while increasing variance for minority classes, ensuring all seizure types receive proportional learning signals regardless of representation. The binary classifier achieves 99.64% specificity and 98.23% sensitivity (ROC-AUC = 0.995). The type classifier demonstrates >99% accuracy across seven seizure categories with perfect (100%) classification for three seizure types despite minimal representation. Cross-dataset validation on the University of Bonn dataset confirms robust generalization (96.0% accuracy) for binary seizure detection. This framework effectively addresses multi-level imbalance in neurophysiological signal classification with hierarchical class structures.