Rasool Dezhkam

Mr. Rasool Dezhkam

Mechanical Engineering, Sharif University of Technology, Tehran, Tehrān, Iran
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2023 in Physics of Fluids
Verified
Journal Article
Open access
PDF file
ABAli Kheirkhah Barzoki
Ali Kheirkhah Barzoki
Rasool DezhkamRasool Dezhkam
Rasool Dezhkam
ASAmir Shamloo
Amir Shamloo
Deterministic lateral displacement (DLD) is a promising method showing great potential in achieving high-resolution separation of suspended particles based on their size, through the use of micropillars arranged in a periodic manner. In the traditional approach to DLD, the migration mode of a particle with a specific size is determined by the critical diameter (Dc), which is predetermined by the device's geometry. In contrast to conventional DLD chips that alter the direction of the pillar array to create an angle with the fluid streamlines, this paper proposes a novel approach by changing the direction of the streamlines. The proposed method enables the fabrication of a tunable DLD chip that is simple to produce and can generate a considerable Dc range by adjusting two control parameters. The first parameter is the ratio of velocity between the main outlet and minor outlets, with the main outlet located at the end of the microchannel and the minor outlets situated on the upper side. The second parameter is the flow rate ratio of two sheath inlets that controls particles' entrance position to the DLD chamber. By manipulating these parameters, Dc can be easily adjusted. This chip features completely horizontal rows of pillars that provide Dc values ranging from 1 to 25 μm.

23 April 2023 in Journal of Industrial and Engineering Chemistry
Verified
Journal Article
Closed access
Rasool DezhkamRasool Dezhkam
Rasool Dezhkam
ASAli Shafiei Souderjani
Ali Shafiei Souderjani
ASAmir Shamloo
Amir Shamloo
MEMohammadmahdi Eskabdarisani
Mohammadmahdi Eskabdarisani
AMAli Mashhadian
Ali Mashhadian

12 December 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
Rasool DezhkamRasool Dezhkam
Rasool Dezhkam
Hoseyn A. AmiriHoseyn A. Amiri
Hoseyn A. Amiri
David J. CollinsDavid J. Collins
David J. Collins
MMMorteza Miansari
Morteza Miansari
Separation and isolation of suspended submicron particles is fundamental to a wide range of applications, including desalination, chemical processing, and medical diagnostics. Ion concentration polarization (ICP), an electrokinetic phenomenon in micro-nano interfaces, has gained attention due to its unique ability to manipulate molecules or particles in suspension and solution. Less well understood, though, is the ability of this phenomenon to generate circulatory fluid flow, and how this enables and enhances continuous particle capture. Here, we perform a comprehensive study of a low-voltage ICP, demonstrating a new electrokinetic method for extracting submicron particles via flow-enhanced particle redirection. To do so, a 2D-FEM model solves the Poisson–Nernst–Planck equation coupled with the Navier–Stokes and continuity equations. Four distinct operational modes (Allowed, Blocked, Captured, and Dodged) were recognized as a function of the particle’s charges and sizes, resulting in the capture or release from ICP-induced vortices, with the critical particle dimensions determined by appropriately tuning inlet flow rates (200–800 [µm/s]) and applied voltages (0–2.5 [V]). It is found that vortices are generated above a non-dimensional ICP-induced velocity of U*=1, which represents an equilibrium between ICP velocity and lateral flow velocity. It was also found that in the case of multi-target separation, the surface charge of the particle, rather than a particle’s size, is the primary determinant of particle trajectory. These findings contribute to a better understanding of ICP-based particle separation and isolation, as well as laying the foundations for the rational design and optimization of ICP-based sorting systems.

6 May 2024 in Talanta
Verified
Journal Article
Closed access
MMMaryam Sadat Mirlohi
Maryam Sadat Mirlohi
EPEsmail Pishbin
Esmail Pishbin
Rasool DezhkamRasool Dezhkam
Rasool Dezhkam
MKMohammad Javad Kiani
Mohammad Javad Kiani
ASAmir Shamloo
Amir Shamloo
SSSiamak Salami
Siamak Salami

1 March 2025 in Physics of Fluids
Verified
Journal Article
Closed access
MTMohammadmahdi Topaheidari
Mohammadmahdi Topaheidari
ASAmir Shamloo
Amir Shamloo
MSMohammad Soleimani
Mohammad Soleimani
AKAmirreza Khodayari
Amirreza Khodayari
Rasool DezhkamRasool Dezhkam
Rasool Dezhkam
ANAli Nouri-Borujerdi
Ali Nouri-Borujerdi
The presence of circulating tumor cells (CTCs) in the bloodstream of patients with cancer offers crucial insights into cancer progression and early diagnosis. In recent research, the detection and separation of CTCs using microfluidic devices have become as a primary point of interest, primarily because of their cost-effectiveness and facile implementation. This study introduces an omega-shaped microfluidic device designed for label-free and rapid enrichment of CTCs. Initial investigations employed numerical simulations to optimize the device geometry for enhanced separation quality. The numerical results indicated that a configuration featuring seven Omega channels at a velocity of 0.5 m/s achieved optimal separation, yielding a 100% recovery rate and 96.8% purity of CTCs. Subsequently, a device comprising seven Omega channels was constructed to evaluate the impact of varying flow velocities on CTC separation from blood cells. Experimental findings revealed that a flow velocity of 0.5 m/s facilitated optimal separation efficiency. Notably, the experimental results demonstrated an 88.8% recovery rate and 83.7% purity for CTCs, aligning with the numerical predictions. Furthermore, surrogate modeling was employed to explore the range of cancer cell types and optimize the aspect ratio parameter. The numerical results indicated an optimal aspect ratio of 0.2 within the designed microchannel, resulting in superior separation performance. In addition, it was observed that CTCs with a diameter greater than 20 μm achieved a 100% recovery rate with a purity of over 97%.

1 October 2024 in Physics of Fluids
Verified
Journal Article
Closed access
PDF file
Rasool DezhkamRasool Dezhkam
Rasool Dezhkam
MTMohammadmahdi Topaheidari
Mohammadmahdi Topaheidari
ZRZohreh Rostami
Zohreh Rostami
ASAmir Shamloo
Amir Shamloo
Cell lysis is one of the main steps in the deoxyribonucleic acid (DNA) extraction process, which makes vital information about organisms accessible for analysis. In the chemical cell lysis process, cells and lysis buffer mix, and the cell membrane is eliminated, and then DNA and other intracellular components are released. Mixing is not an easy step in microfluidic systems, and it reduces the chemical cell lysis efficiency. Therefore, a novel method has been implemented to address this issue. In this work, a magnetophoretic separation method is utilized to eliminate the mixing process and guide target cells directly inside the lysis buffer flow; integrating cell separation and cell lysis into a single platform enhances lysis efficiency. This method selectively lyses only the target cells that are pre-labeled with the antibody from the mixture of cells. These phenomena are combined in one simple straight channel and decrease the area used by the system, which is a desired goal in microsystems. Both numerical and experimental methods are utilized to separate magnetized cancer cells as circulating tumor cells from blood cells and guide them to a region having an appropriate concentration of lysis buffer. To optimize the system, parameters including inlet velocity, number of magnets, and distance between magnets and channel were studied, whereby 8 mm and five magnets were considered for optimum values of distance and number of magnets, respectively. According to the results, the fluid velocity was the key parameter for the target cell lysis phenomenon due to its influence on both mass transfer and cell separation phenomena. It was observed that lower velocities resulted in more cell separation efficiency, and higher velocities had better outcome in mass transfer. Finally, between a wide range of velocities from 0.1 to 50 mm/s, the 10 mm/s velocity was selected as the optimum inlet velocity, which showed 100% separation efficiency and a concentration of 0.55 mM for the target outlet.