Rawan Fahad Alsaif

Dr. Rawan Fahad Alsaif


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 February 2023 in Photodiagnosis and Photodynamic Therapy
Verified
Journal Article
Closed access
HAHussain D. Alsayed
Hussain D. Alsayed
IBIshfaq A Bukhari
Ishfaq A Bukhari
RARawan Fahad Alsaif
Rawan Fahad Alsaif
FVFahim Vohra
Fahim Vohra

29 March 2023 in Photodiagnosis and Photodynamic Therapy
Verified
Journal Article
Closed access
FVFahim Vohra
Fahim Vohra
IKIsaac Kuyunov
Isaac Kuyunov
RARawan Fahad Alsaif
Rawan Fahad Alsaif
AMAminah M. El Mourad
Aminah M. El Mourad

2 May 2023 in Microscopy Research and Technique
Verified
Journal Article
Closed access
FVFahim Vohra
Fahim Vohra
RARenad R. Alamri
Renad R. Alamri
FAFatimah O. Almohsen
Fatimah O. Almohsen
AMAminah M. El Mourad
Aminah M. El Mourad
IMRAN FAROOQIMRAN FAROOQ
IMRAN FAROOQ
RARawan Fahad Alsaif
Rawan Fahad Alsaif

25 August 2024 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
FVFahim Vohra
Fahim Vohra
RARawan Fahad Alsaif
Rawan Fahad Alsaif
RKRawaiz Khan
Rawaiz Khan
IBIshfaq A Bukhari
Ishfaq A Bukhari
Background: Marginal misfit and surface roughness of customized implant abutments is critical for restorative success. However, little is known about the comparison of misfit and surface roughness of CAD-CAM Zirconium oxide (ZrO), selective laser melting (SLM) Cobalt Chrome (CoCr) and preformed abutments. The aim of the study is to investigate the relation of misfit and micro-roughness of selective laser melting (SLM), preformed and CAD-CAM implant abutments. Methods: Thirty internal connection, endosseous dental implants (Ø 4.0 mm x 10 mm, Dentium) were mounted in Polymethyl methacrylate vertically. Ten preformed Titanium alloy (Ti) abutments with 1 mm soft tissue height and Ø 4.5 mm were included as controls. Ten each of Y-TZP and SLM-CoCr, abutment/crowns were fabricated using CAD-CAM milling (CAD-CAM-ZrO) and SLM techniques. Surface micro-roughness (Ra) of the fabricated implant abutment/crown was evaluated with a 3D optical non-contact microscope. All implant restorations were torqued to implants (30 Ncm) using a Tohnichi BTGE digital torque gauge and were analyzed with Bruker micro-CT (Skyscan 1173) to detect micro-gaps at pre-selected points at implant abutment interface. The Ra and misfit data were compared using ANOVA, Tukey-Kramer, Kruskal-Wallis test and Pearson correlation (p < 0.05). Results: Mean Ra among SLM CoCr abutments [0.88 (0.09) µm] were lower than CAD-CAM-ZrO and higher than preformed Ti abutments. Horizontal misfit among SLM-CoCr [45.43 (9.41) µm] and preformed Ti [36.87 (13.23) µm] abutments was not statistically different (p > 0.05). Misfit was significantly higher in Y-TZP samples compared to SLM-CoCr (p = 0.031) and preformed Ti abutments (p = 0.01). Preformed Ti abutments showed significantly lower misfit compared to SLM-CoCr abutments (p = 0.01). A positive linear correlation was observed between the surface roughness (Ra) and vertical misfit (r = 0.61, p < 0.05). Conclusion: SLM CoCr abutments showed rough surface compared to preformed Ti abutments, while horizontal misfit was comparable among SLM-CoCr and preformed abutments. Misfit was significantly greater in Y-TZP abutments, compared to SLM and preformed abutments. SLM abutment fabrication technique needs further improvement to provide better fit and surface topography.

30 April 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
FVFahim Vohra
Fahim Vohra
RARawan Fahad Alsaif
Rawan Fahad Alsaif
RKRawaiz Khan
Rawaiz Khan
IBIshfaq A. Bukhari
Ishfaq A. Bukhari
Aim: This study aimed to compare the torque loss, fracture load, compressive strength, and failure types of selective-laser-sintered cobalt chromium (SLM-Co-Cr), computer-aided design and computer-aided manufacturing zirconium oxide (CAD-CAM-ZrO), and machined titanium (Ti) implant abutments. Methods: Thirty endosseous dental implants were vertically embedded with machined Ti (control group), CAD-CAM-ZrO, and SLM-Co-Cr abutments. Abutment fabrication involved CAD-CAM milling and SLM technology. The de-torque assessment included preload reverse torque values (RTVs), cyclic loading, and post-RTVs using a customized protocol. Fracture load assessment employed ISO-14801 standards, and statistical analysis was conducted using ANOVA and Tukey Post hoc tests (p < 0.05). Results: In pre-load RTVs, SLM-Co-Cr showed the lowest mean torque loss (24.30 ± 2.13), followed by machined Ti (27.33 ± 2.74) and CAD-CAM-ZrO (22.07 ± 2.20). Post-load RTVs decreased for all groups. Fracture load and compressive strength were highest for SLM-Co-Cr, with significant differences among groups (p < 0.001). Fracture types included abutment failures in SLM-Co-Cr and machined Ti, while CAD-CAM-ZrO exhibited crown separation with deformation. Conclusion: SLM-Co-Cr-fabricated implant abutments exhibited superior stability and resistance to rotational forces, higher fracture loads, and greater compressive strength compared to CAD-CAM-ZrO and machined Ti.