Rawaiz Khan

Dr. Rawaiz Khan

College Of Dentistry, King Saud University, Riyadh, Saudi Arabia

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 September 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
NANada Aldahian
Nada Aldahian
RKRawaiz Khan
Rawaiz Khan
Mohammed MustafaMohammed Mustafa
Mohammed Mustafa
FVFahim Vohra
Fahim Vohra
AAAli Alrahlah
Ali Alrahlah
The aim is to assess the influence of fabrication techniques—conventional (CN), CAD-CAM (CC), and 3D printing (3D)—on the marginal fit, adaptation, surface roughness, and wear of interim restorations of crowns. Thirty interim crowns were fabricated using CN, CC, and 3D techniques. Sixty discs were fabricated to evaluate surface wear and surface roughness properties, with 10 disc samples in each group (n = 10). Internal adaptation and marginal integrity of interim crowns were analyzed with micro CT to detect microgaps at selected points. Average surface micro-roughness (Ra) was calculated in micrometers (μm) using an optical non-contact surface microscope under cyclic loading. Surface wear was evaluated by surface area measurements (mm3) using a micro CT. Analysis of variance (ANOVA) and Tukey’s post hoc comparison tests with Pearson correlation were performed for data analysis. The highest adaptation means were for CN (269.94 ± 64 μm), and the lowest mean value was observed for 3D (197.82 ± 11.72 μm) crowns. CN and CC specimens showed comparable adaptation (p > 0.05), which were significantly higher (p < 0.05) than 3D crowns. CN crowns showed significantly higher marginal misfit compared to 3D (p < 0.05) and CC (p < 0.05) crowns. The highest mean surface roughness was observed in the 3D crowns (5.61 ± 0.33 µm), whereas the lowest was found in CC crowns (3.28 ± 0.34 µm). Better restoration Ra was observed using the CC method followed by CN. CN had the highest wear (17.79 ± 2.78 mm3), and the lowest wear was observed in the 3D (10.81 ± 2.00 mm3) specimen. Low surface wear was observed using 3D printing, followed by CN and CC techniques. The printed specimen showed comparable outcomes to CAD-CAM restoration; however, they were better than CN restoration. A positive correlation between adaptation and surface roughness was observed, indicating an effect of the fabrication technique on material physical property.

17 December 2020 in Polymers
Verified
Journal Article
Open access
PDF file
AAAli Alrahlah
Ali Alrahlah
RKRawaiz Khan
Rawaiz Khan
Abdel-Basit Al-OdayniAbdel-Basit Al-Odayni
Abdel-Basit Al-Odayni
Waseem Sharaf SaeedWaseem Sharaf Saeed
Waseem Sharaf Saeed
LBLeonel S. Bautista
Leonel S. Bautista
FVFahim Vohra
Fahim Vohra
Graphene and graphene oxide based nanomaterials have attained immense significance in research because of their matchless physiochemical characteristics. Although potential biomedical applications of graphene have been extensively studied, however, dentistry related applications were rarely explored. This study aimed to investigate the effect of various percentages of surface modified reduce graphene oxide (S-rGO) in combination with SiO2 nanoparticles (bulk filler) on numerous physio-mechanical characteristics of acrylate-based (BisGMA/TEGDMA: 1:1 by wt.) composites. BisGMA/TEGDMA reinforced with 30 wt.% surface modified fumed-silica (S-A200) was considered as control group (base composite). Various concentrations (0, 0.5, 1, 2, 4 wt.%) of S-rGO were incorporated into the base composite via solution casting and high-speed mixing. The obtained composites were characterized for rheological properties before curing by using Rheometer (Anton Paar, USA) in the oscillatory mode under a frequency sweep over a range of angular frequency of 0.1–100 rad/s at 25 °C. The degree of conversion (DC) was measured by using Fourier transform infrared spectroscopy (FTIR). A Nano-indentation test was carried out to obtain nano-hardness and elastic modulus. The surface roughness was measured by optical microscope (Bruker®), 3D non-contact surface profilometer. The structural and morphological properties were studied by using Scanning Electron Microscopy (SEM). The mean and standard deviation were calculated and a simple mean comparisons test was performed for comparison using SPSS. The results revealed that the addition of a tiny proportion of S-rGO considerably increased the nano-indentation hardness, elastic modulus and DC. Conversely, a gradual reduction in viscosity was observed with increasing S-rGO concentration. The study demonstrates that a small fraction of S-rGO in combination with SiO2 could enhance physical, mechanical and rheological properties of acrylate based composites. Thus S-rGO/SiO2 combination could be used as a potential hybrid filler for dental nanocomposites.

8 September 2015 in Journal of Coatings Technology and Research
Verified
Journal Article
Closed access
PDF file
RKRawaiz Khan
Rawaiz Khan
Muhammad Rizwan AzharMuhammad Rizwan Azhar
Muhammad Rizwan Azhar
Arfat AnisArfat Anis
Arfat Anis
MAMohammad Asif Alam
Mohammad Asif Alam
MBM. Boumaza
M. Boumaza
SASaeed M. Al-Zahrani
Saeed M. Al-Zahrani

6 August 2019 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
Mohamed Moustafa AwadMohamed Moustafa Awad
Mohamed Moustafa Awad
LALamees Albedaiwi
Lamees Albedaiwi
AAAhmed Almahdy
Ahmed Almahdy
RKRawaiz Khan
Rawaiz Khan
Nikolaos SilikasNikolaos Silikas
Nikolaos Silikas
AAAli Alrahlah
Ali Alrahlah
The aim of this study was to evaluate the effect of universal adhesives (UA) and silane on the microtensile bond strength (μTBS) of resin cement to a hybrid ceramic Vita Enamic (VE). VE specimens were acid etched using hydrofluoric acid (HF) and were assigned to three groups (n = 10) based on the applied bonding technique. In group 1 (S), a silane-based primer was used as a surface treatment prior to the application of a resin cement (Variolink Esthetic DC). In group 2, a silane-containing UA, Clearfil Universal Bond (CUB) was used for the surface treatment, and in group 3, A silane-free UA, Tetric N-Bond Universal (TNU) was used for surface treatment. Resin cement build-ups were prepared. The bonded specimens were sectioned into resin-ceramic beams. Half of the beams of each group were stored for 24 h at 37 °C and the other half were subjected to a thermo-cycling aging. The microtensile bond strength (μTBS) was measured at a crosshead speed of 0.5 mm/min. Failure modes were assessed accordingly. Data were analyzed using a) two-way analysis of variance ANOVA followed by one-way ANOVA and Tukey tests between groups and b) independent t-test to detect differences (α = 0.05) for each group. The surface topographies of the ceramic surface were evaluated using scanning electron microscopy. The results showed that silane-based primer (S) application resulted in significantly higher (p < 0.05) μTBS values after 24 h and after thermocycling compared to both silane-containing UA (CUB) and silane-free UA (TNU). The μTBS values of all groups were significantly reduced after thermocycling. No statistically significant difference was observed between the μTBS of CUB and TNU after 24 h. However, TNU showed significantly higher μTBS after thermocycling. Different failure modes were observed, and adhesive failure was the most common in all groups. Marked surface topographic changes were observed following HF etching. It is concluded that, the UAs tested cannot be recommended as substitutes to the silanization of Hybrid ceramic.

11 January 2021 in Materials
Verified
Journal Article
Open access
PDF file
AAAli Alrahlah
Ali Alrahlah
Abdel-Basit Al-OdayniAbdel-Basit Al-Odayni
Abdel-Basit Al-Odayni
HAHaifa Fahad Al-Mutairi
Haifa Fahad Al-Mutairi
BABashaer Mousa Almousa
Bashaer Mousa Almousa
Faisal AlsubiaeFaisal Alsubiae
Faisal Alsubiae
Waseem Sharaf SaeedWaseem Sharaf Saeed
Waseem Sharaf Saeed
This study aimed to synthesize new bisphenol A-glycidyl methacrylate (BisGMA) derivatives, targeting a reduction in its viscosity by substituting one of its OH groups, the leading cause of its high viscosity, with a chlorine atom. Hence, this monochloro-BisGMA (mCl-BisGMA) monomer was synthesized by Appel reaction procedure, and its structure was confirmed using Fourier transform infrared spectroscopy, 1H and 13C-nuclear magnetic resonance spectroscopy, and mass spectroscopy. The viscosity of mCl-BisGMA (8.3 Pa·s) was measured under rheometry conditions, and it was found to be more than 65-fold lower than that of BisGMA (566.1 Pa·s) at 25 °C. For the assessment of the viscosity changes of model resins in the presence of mCl-BisGMA, a series of resin matrices, in which, besides BisGMA, 50 wt % was triethylene glycol dimethacrylate, were prepared and evaluated at 20, 25, and 35 °C. Thus, BisGMA was incrementally replaced by 25% mCl-BisGMA to obtain TBC0, TBC25, TBC50, TBC75, and TBC100 blends. The viscosity decreased with temperature, and the mCl-BisGMA content in the resin mixture increased. The substantial reduction in the viscosity value of mCl-BisGMA compared with that of BisGMA may imply its potential use as a dental resin matrix, either alone or in combination with traditional monomers. However, the various properties of mCl-BisGMA-containing matrices should be evaluated.

10 July 2018 in Materials
Verified
Journal Article
Open access
PDF file
AAAli Alrahlah
Ali Alrahlah
RKRawaiz Khan
Rawaiz Khan
KAKhalid Alotaibi
Khalid Alotaibi
ZAZiad Almutawa
Ziad Almutawa
HFHassan Fouad
Hassan Fouad
Nikolaos SilikasNikolaos Silikas
Nikolaos Silikas
The aim of this study is to compare the creep/recovery behavior of bulk-fill dental composites after storage in various food simulating organic solvents. For this purpose, five different resin-composites (four bulk-fills and one conventional) were used. A total of 20 rectangular specimens (14 mm × 3 mm × 0.7 mm) were prepared by filling the resin-composites in Teflon mold. All of the specimens for each material (n = 5) were divided into four groups namely dry (control), distilled water (DW), artificial saliva, and absolute ethanol. The specimens were subjected to three-point bending creep test during immersion directly. A constant load of 2 N was used for each specimen with loading and unloading time 2 h each. Results: SF2 and XF showed a lower creep strain % after immersion, ranging from 0.44 (dry) to 0.75 (saliva) and 0.43 (dry) to 0.80 (ethanol), respectively. TNC BF depicts the maximum creep strain % ranging from 1.24% (dry) to 2.87% (ethanol) followed by FBF ranging from 1.17 (dry) to 2.59 (ethanol). However, the conventional material (GR) showed lower creep strain after immersion ranging from 0.28 to 0.54. Moreover, SF2 resulted in the highest creep recovery in all of the composites groups, as well as conventional material. The other composite groups showed lower creep recovery as compared to the conventional material (GR). The creep strain % for all the bulk-fill composites materials were increased during immersion in the liquids. However, for the conventional material, the creep deformation is decreased after immersion. SF2 showed the highest percentage of creep recovery among the bulk-fill composites, followed by XF.