Ricardo Trujillo

Dr. Ricardo Trujillo

NTNU
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 March 2021 in Sensors
Verified
Journal Article
Open access
PDF file
RTRicardo Trujillo
Ricardo Trujillo
Daniela BarrazaDaniela Barraza
Daniela Barraza
MZMartin Lucas Zamora
Martin Lucas Zamora
ACAnna Cattani-Scholz
Anna Cattani-Scholz
Rossana MadridRossana Madrid
Rossana Madrid
In recent years, several devices have been developed for the direct measurement of hydrogen peroxide (H2O2), a key compound in biological processes and an important chemical reagent in industrial applications. Classical enzymatic biosensors for H2O2 have been recently outclassed by electrochemical sensors that take advantage of material properties in the nano range. Electrodes with metal nanoparticles (NPs) such as Pt, Au, Pd and Ag have been widely used, often in combination with organic and inorganic molecules to improve the sensing capabilities. In this review, we present an overview of nanomaterials, molecules, polymers, and transduction methods used in the optimization of electrochemical sensors for H2O2 sensing. The different devices are compared on the basis of the sensitivity values, the limit of detection (LOD) and the linear range of application reported in the literature. The review aims to provide an overview of the advantages associated with different nanostructures to assess which one best suits a target application.

1 October 2015 in Materials Science and Engineering: B
Verified
Journal Article
Open access
LSLuciano D. Sappia
Luciano D. Sappia
RTRicardo Trujillo
Ricardo Trujillo
ILIsrael Lorite
Israel Lorite
RMRossana E. Madrid
Rossana E. Madrid
MTMonica Tirado
Monica Tirado
Pablo EsquinaziPablo Esquinazi
Pablo Esquinazi

4 October 2023 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
RTRicardo Trujillo
Ricardo Trujillo
GAG. Almanza
G. Almanza
DSD. Sanchez-Saldaña
D. Sanchez-Saldaña
ØRØ. Rosand
Ø. Rosand
Morten HøydalMorten Høydal
Morten Høydal
CDCarlos Dorao
Carlos Dorao
Although several lysis methods are available, biomedical applications are pushing the demand for miniaturised systems and thus for new ways to lyse cells in small volumes.

1 December 2023 in Biomicrofluidics
Verified
Journal Article
Closed access
PDF file
GAG. Almanza
G. Almanza
RTRicardo Trujillo
Ricardo Trujillo
DSD. Sanchez-Saldaña
D. Sanchez-Saldaña
ØRØ. Rosand
Ø. Rosand
Morten HøydalMorten Høydal
Morten Høydal
CDCarlos Dorao
Carlos Dorao
The efficient breakage of one cell or a concentration of cells for releasing intracellular material such as DNA, without damaging it, is the first step for several diagnostics or treatment processes. As the cell membrane is easy to bend but resistant to stretching, the exposure of the cell to a shear rate during a short period of time can be sufficient to damage the membrane and facilitate the extraction of DNA. However, how to induce high shear stresses on cells in small microliter volumes samples has remained an elusive problem. Surface acoustic waves operating at high frequencies can induce acoustic streaming leading to shear rates sufficient to cell lysis. Lysis induced by acoustic streaming in sessile droplets has been investigated in the past from the lysis efficiency point of view. However, the effects of the velocity field and shear rate induced by acoustic streaming on the lysis process remain unexplored. Here, we study the lysis of AC16 human cardiomyocytes in microliter droplets under the effect of the shear rate induced by acoustic streaming. It is identified that for a given shear rate, the extracted DNA is also affected by the actuation period which can be attributed to a cycling process that leads to an accumulation of damage on the cell membrane.

7 August 2014 in IEEE Latin America Transactions
Verified
Journal Article
Closed access
MZMartin Lucas Zamora
Martin Lucas Zamora
RTRicardo Trujillo
Ricardo Trujillo
CFCarmelo Jose Felice
Carmelo Jose Felice
Non-linear Dielectric spectroscopy of Biological suspensions was first proposed by the Woodward and Kell group. The above mentioned arose as a technique able to monitor the enzymes state placed in the cell membrane of the biological tissue. This technique is limited to such enzymes because an external low frequency electrical field notably disturbs the membrane's electrical entourage. This kind of interactions can be monitor if the system generates current harmonics. This phenomenon was theorized by Astumian and Robertson. Treo, on his work suggests that the harmonics are originated at the interface and altered by the microorganism presence. Then Ruiz developed a fast method to detect the global non-linearity of a biological suspension. Nevertheless, on these works, the non-linearity interference due to the electrode-electrolyte interface was not controlled. The observed response is the result of the interface modulation because of the microorganism presence. On our work, we employed a tripolar measurement cell. The working electrode (WE) is a gold disc, the counter electrode (CE) is made of stainless steel and the reference electrode (RE) is a standard Ag/AgCl electrode. 1.74 g of lyophilized Saccharomyces cerevisiae was dissolved in 90 ml of saline medium. A frequency (0.1 - 1000 Hz) and tension AC (0- 600 mV) sweep was carried out without DC polarization. The first 5 output current harmonics were monitored. Results would indicate that it was successfully possible to measure the non-linearity due to only the yeasts cells, without the non-linear interference of the electrode - electrolyte interface.