Sergio Raul Rojas-Ramirez

Dr. Sergio Raul Rojas-Ramirez


Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 January 2026 in Sensors
Verified
Journal Article
Open access
PDF file
SCSara Isabel González Cabrera
Sara Isabel González Cabrera
NZNahum Camacho Zamora
Nahum Camacho Zamora
Sergio Raul Rojas-RamirezSergio Raul Rojas-Ramirez
Sergio Raul Rojas-Ramirez
Arantxa Montserrat Gonzalez AguilarArantxa Montserrat Gonzalez Aguilar
Arantxa Montserrat Gonzalez Aguilar
AVAnd Marco Osvaldo Vigueras-Zúñiga
And Marco Osvaldo Vigueras-Zúñiga
MCMaria Elena Tejeda del Cueto
Maria Elena Tejeda del Cueto
Monitoring mechanical vibration is crucial for ensuring the structural integrity and optimal performance of unmanned aerial vehicles (UAVs). This study introduces a portable and low-cost system that enables integrated acquisition and analysis of UAV vibration data in a single step, using a Raspberry Pi 4B, data acquisition (DAQ) through a MCC128 DAQ HAT card, and six accelerometers positioned at strategic structural points. Ground-based engine tests at 2700 RPM allowed vibration data to be recorded under conditions similar to those of real operation. Data was processed with a Kalman filter, a Hann window function application, and frequency analysis via Fast Fourier Transform (FFT). The first and second wing bending natural frequencies were identified at 12.3 Hz and 17.5 Hz, respectively, as well as a significant component around 23 Hz, which is a subharmonic of the propulsion system excitation frequency near 45 Hz. The results indicate that the highest vibration amplitudes are concentrated at the wingtips and near the engine. The proposed system offers an accessible and flexible alternative to commercial equipment, integrating acquisition, processing, and real-time visualization. Moreover, its implementation facilitates the early detection of structural anomalies and improves the reliability and safety of UAVs.

4 June 2008
Verified
Conference Paper
Closed access
PDF file
GPGuillermo Silva Pineda
Guillermo Silva Pineda
HMHans-Jürgen von Martens
Hans-Jürgen von Martens
Sergio Raul Rojas-RamirezSergio Raul Rojas-Ramirez
Sergio Raul Rojas-Ramirez
ARArturo Ruiz
Arturo Ruiz
LMLorenzo Muñiz
Lorenzo Muñiz
Manufacturers and users of laser vibrometers exploit the wide frequency and intensity ranges of laser techniques, ranging over many decades (e.g., from 0.1 Hz to 100 MHz). Traceability to primary measurement standards is demanded over the specified measurement ranges of any measurement instrumentation. As the primary documentary standard ISO 16063-11 for the calibration of vibration transducers is restricted to 10 kHz, a new international standard for the calibration of laser vibrometers, ISO 16063-41, is under development. The current stage of the 2nd Committee Draft (CD) of the ISO standard specifies calibration methods for frequencies from 0.4 Hz to 50 kHz which does not meet the demand for providing traceability at higher frequencies. New investigations will be presented which demonstrate the applicability of the laser interferometer methods specified in ISO 16063-11 and in the 2nd CD also at higher frequencies of 100 kHz and beyond. The three standard methods were simultaneously used for vibration displacement and acceleration measurements up to 100 kHz, and a fourth high-accuracy method has been developed and used. Their results in displacement and acceleration measurements deviated by less than 1 % from each other at vibration displacement amplitudes in the order of 100 nm. In addition to the three interferometer methods specified in ISO 16063-11 and 16063-15, and in the 2nd Committee Draft of 16063-41 as well, measurement results will be presented. Examples of laser vibrometer calibrations will bedemonstrated. Further investigations are aimed

12 August 2026 in Education Sciences
Verified
Journal Article
Open access
PDF file
PAPedro Cruz Alcantar
Pedro Cruz Alcantar
Rafael Alfonso Figueroa DíazRafael Alfonso Figueroa Díaz
Rafael Alfonso Figueroa Díaz
Antonio BalvantinAntonio Balvantin
Antonio Balvantin
Sergio Raul Rojas-RamirezSergio Raul Rojas-Ramirez
Sergio Raul Rojas-Ramirez
Oscar Alejandro Garcia-PerezOscar Alejandro Garcia-Perez
Oscar Alejandro Garcia-Perez
MTMaría Terrones-Gurrola
María Terrones-Gurrola
The digital transformation associated with Industry 4.0 has increased the demand for engineers with competencies in condition monitoring, the Internet of Things (IoT), and artificial intelligence (AI). However, evidence on educational methodologies integrating these technologies within a competency-based assessment framework remains limited. This study developed and preliminarily evaluated a competency-based educational methodology and characterized the technical, digital, and analytical competency profiles of Mechanical Engineering students following participation in smart maintenance learning activities. A descriptive–exploratory case study was conducted with 31 students enrolled in an Industrial Maintenance course. The methodology integrated vibration analysis, infrared thermography, acoustic monitoring, IoT-based remote monitoring, and ChatGPT-assisted fault diagnosis. Competencies were assessed using an analytic rubric applied by six faculty evaluators, while students’ perceptions were examined through a 22-item questionnaire. The Global Competency Index for Smart Maintenance (GCIIM) was 72.86%, indicating a moderate overall competency level. Critical evaluation of artificial intelligence achieved the highest score, whereas fault diagnosis, technical communication, and technological adaptability showed the lowest performance. Students reported a favorable overall perception score (75.04%) across the questionnaire dimensions. These findings provide preliminary evidence of the feasibility of an integrated competency-based framework for smart maintenance education and its potential to support the responsible incorporation of digital technologies and artificial intelligence into engineering curricula.

12 May 2026 in Enfermería Universitaria
Verified
Journal Article
Open access
OGOrlando Guarneros García
Orlando Guarneros García
Sergio Raul Rojas-RamirezSergio Raul Rojas-Ramirez
Sergio Raul Rojas-Ramirez
Alejandro ZacaríasAlejandro Zacarías
Alejandro Zacarías
Geydy Gutiérrez-UruetaGeydy Gutiérrez-Urueta
Geydy Gutiérrez-Urueta
Introducción: El uso de equipos de medición para determinar una magnitud (temperatura, presión, concentración, entre otras) es relevante en la práctica diagnóstica. Se parte de la presunción de que sus resultados son incuestionables, pero es necesario comprender algunos conceptos de la metrología. La falta de conocimiento de la calibración y la trazabilidad metrológica de los equipos, así como de su asociación con una incertidumbre de medida, no garantizan la confiabilidad de los resultados de los equipos, lo que representa un problema dado que, con estos resultados, los profesionales de la salud diagnostican. Objetivo: Comprender el papel que tienen la calibración, la trazabilidad metrológica y la incertidumbre de medida para la determinación del resultado de una medición, y su impacto en la práctica diagnóstica. Desarrollo: Es evidente la importancia de los equipos de medición como herramientas para diagnosticar. Sin embargo, dadas las variaciones que puede haber en una medición, se vuelve necesario haber comparado el equipo de medición físicamente con una referencia (calibración), documentar su relación con un laboratorio de ensayo y calibración primario (trazabilidad metrológica) y cuantificar su variabilidad (incertidumbre de medida). Conclusión: La cuantificación de una magnitud con un equipo de medición requiere, además de cierta habilidad para la operación de este, tanto la interpretación de los resultados como la identificación de la calibración, trazabilidad metrológica e incertidumbre de medida, de tal forma que se tengan los elementos para que el equipo de medición realmente sirva de manera objetiva como herramienta en la práctica diagnóstica.

1 July 2015 in Experimental Mechanics
Verified
Journal Article
Closed access
PDF file
Sergio Raul Rojas-RamirezSergio Raul Rojas-Ramirez
Sergio Raul Rojas-Ramirez
FOF.-J. Ornelas-Rodriguez
F.-J. Ornelas-Rodriguez
JHJuan Bautista Hurtado-Ramos
Juan Bautista Hurtado-Ramos
José-Joel Gonzalez-BarbosaJosé-Joel Gonzalez-Barbosa
José-Joel Gonzalez-Barbosa
RZR. Zitzumbo
R. Zitzumbo