Rui Zhou

Prof. Dr. Rui Zhou

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 February 2021 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
Rui ZhouRui Zhou
Rui Zhou
FCFengyi Chen
Fengyi Chen
SLShuangshuang Li
Shuangshuang Li
XQXueguang Qiao
Xueguang Qiao
XQXueguang Qiao
Xueguang Qiao
We have designed, fabricated, and characterized a fiber-optic three-dimensional vector accelerometer for vibration measurement. The accelerometer is based on fiber Bragg gratings (FBGs) inscribed with three cores of seven-core fiber by femtosecond laser with a phase mask. Through monitoring the wavelength shifts of two of the seven cores, we obtain the vibration azimuthal angle and the acceleration in the XY plane by angle reconstruction and algorithmic calculation. Similarly, by monitoring the wavelength shift of the core fixed along the Z-axis, we obtain the vibration acceleration in the Z-axis direction. The full 3D vector information about the vibration signal is obtained by vector synthesis. The accelerometer has achieved a working frequency bandwidth from 10 to 220 Hz with the maximum sensitivity of 355 pm/g, and the best azimuthal angle accuracy of 0.269 ° in the linear range of 0 ° -100 ° and 170 ° -280 ° . Moreover, it is possible to increase the overall bandwidth, sensitivity and accuracy of the azimuth of sensors in the XY plane by adjusting the length of the optical fiber and adjusting mechanical parameters to increase the bandwidth and sensitivity of the sensor in Z-axis. Such improvements will further enhance application to small-scale seismic surveys.

11 February 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Rui ZhouRui Zhou
Rui Zhou
XQXueguang Qiao
Xueguang Qiao
XQXueguang Qiao
Xueguang Qiao
FCFengyi Chen
Fengyi Chen
WMWenwen Ma
Wenwen Ma
We demonstrate a fiber-optic strain sensor based on a seven-core fiber (7-CF) for accurate extrusion bending and tensile strain sensing. The sensor structure we designed is the 7-CF spliced to a piece of multimode fiber on each side with a lateral core-offset and then conventionally fused to single mode optical fiber as the input and output ports. The experimental results indicate that the optimal curvature sensitivity of the sensor is achieved 25.96 nm/m-1, and the sensitivity of the tensile strain is 0.094 nm/με, which allows us to monitor bending and stretching strain respectively with high precision by the simple, low-cost, and effective sensor.

1 September 2021 in Optical Fiber Technology
Verified
Journal Article
Closed access
SLShuangshuang Li
Shuangshuang Li
ZFZhongyao Feng
Zhongyao Feng
QMQiqi Ma
Qiqi Ma
XQXueguang Qiao
Xueguang Qiao
Rui ZhouRui Zhou
Rui Zhou
XQXueguang Qiao
Xueguang Qiao

5 January 2023 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
YYYing Yue
Ying Yue
XHXixi Hu
Xixi Hu
Rui ZhouRui Zhou
Rui Zhou
XQXueguang Qiao
Xueguang Qiao
XQXueguang Qiao
Xueguang Qiao
The highly sensitive CO 2 detective instrument is intensively studied recently for the atmosphere protection. Fiber-optic interferometer is widely used as a gas sensor because its interference wavelength can be influenced by the environmental refractive index. In this work, by adopting the nanoparticles self-assembly technology, a spherical optical device with a primary pore width of 8.13 nm and a specific surface area as large as 74.58 m 2 /g is fabricated. For gas detection, the larger the specific surface area of the device, the more gas molecules being adsorbed, resulting in a higher sensitivity. A Fabry-Perot fiber-optic interferometer is designed by mounting the self-assembled device on a fiber end face. In the experiment, it shows a fast response time of 21 s, a high wavelength sensitivity of 200 pm/%, and a wide detection range from 350 ppm to 36% for CO 2 gas. It also performs a high selectivity, good repeatability, and immunity to the gas flow rate. Such a Fabry-Perot interferometer, as a standard lab-on-fiber device, will have a significant application potential for trace CO 2 monitoring in the field of carbon capture, utilization, and storage (CCUS).

11 July 2023 in Optical Fiber Technology
Verified
Journal Article
Closed access
HLHuidong Li
Huidong Li
XZXuan Zhang
Xuan Zhang
Rui ZhouRui Zhou
Rui Zhou
XQXueguang Qiao
Xueguang Qiao

18 October 2022 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Rui ZhouRui Zhou
Rui Zhou
WHWenyu Hu
Wenyu Hu
CYChanghao Yi
Changhao Yi
YLYizhuo Li
Yizhuo Li
YSYuanhao Su
Yuanhao Su
XQXueguang Qiao
Xueguang Qiao
Multiplexing technology is important when realizing multipoint measurement. We propose a vector accelerometer based on a silicone rubber compliant cylinder, which makes it easy to realize multistage cascaded multiplexing. The proposed accelerometer has natural frequencies of 19 to 39 Hz, which increase with an increased Shore A material hardness and a shortened the length of the intermediate part of the compliant cylinder. In addition, at a random orientation, the maximum sensitivity reaches 340.6 pm/g when subjected to a 10 Hz vibration excitation. Moreover, the accelerometer can recognize the vibration orientation from 0 to 360°. With high integration, small size, and multistage cascaded multiplexing, the accelerometer is especially suitable for narrow spaces multipoint measurement.