Eduardo Ruiz Velázquez

Dr. Eduardo Ruiz Velázquez

Ciencias Computacionales, Universidad de Guadalajara, CUCEI, Guadalajara, Jalisco, Mexico
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2020 in Journal of the Franklin Institute
Verified
Journal Article
Closed access
Eduardo Ruiz VelázquezEduardo Ruiz Velázquez
Eduardo Ruiz Velázquez
JGJulio Alberto García–Rodríguez
Julio Alberto García–Rodríguez
GQGriselda Quiroz
Griselda Quiroz
Ricardo FematRicardo Femat
Ricardo Femat

1 February 2019 in IET Systems Biology
Verified
Journal Article
Open access
PDF file
OSOscar D. Sánchez
Oscar D. Sánchez
Eduardo Ruiz VelázquezEduardo Ruiz Velázquez
Eduardo Ruiz Velázquez
Alma Y. AlanisAlma Y. Alanis
Alma Y. Alanis
GQGriselda Quiroz
Griselda Quiroz
LTLuis Torres-Treviño
Luis Torres-Treviño
The effect of meal on blood glucose concentration is a key issue in diabetes mellitus because its estimation could be very useful in therapy decisions. In the case of type 1 diabetes mellitus (T1DM), the therapy based on automatic insulin delivery requires a closed‐loop control system to maintain euglycaemia even in the postprandial state. Thus, the mathematical modelling of glucose metabolism is relevant to predict the metabolic state of a patient. Moreover, the eating habits are characteristic of each person, so it is of interest that the mathematical models of meal intake allow to personalise the glycaemic state of the patient using therapy historical data, that is, daily measurements of glucose and records of carbohydrate intake and insulin supply. Thus, here, a model of glucose metabolism that includes the effects of meal is analysed in order to establish criteria for data‐based personalisation. The analysis includes the sensitivity and identifiability of the parameters, and the parameter estimation problem was resolved via two algorithms: particle swarm optimisation and evonorm. The results show that the mathematical model can be a useful tool to estimate the glycaemic status of a patient and personalise it according to her/his historical data.

4 June 2025 in Diabetology
Verified
Journal Article
Open access
PDF file
Alberto Gudiño-OchoaAlberto Gudiño-Ochoa
Alberto Gudiño-Ochoa
Julio Alberto García-RodríguezJulio Alberto García-Rodríguez
Julio Alberto García-Rodríguez
Raquel Ochoa OrnelasRaquel Ochoa Ornelas
Raquel Ochoa Ornelas
Eduardo Ruiz VelázquezEduardo Ruiz Velázquez
Eduardo Ruiz Velázquez
Sofia Uribe-ToscanoSofia Uribe-Toscano
Sofia Uribe-Toscano
Sanchez Arias Daniel AlejandroSanchez Arias Daniel Alejandro
Sanchez Arias Daniel Alejandro
Background/Objectives: The increasing prevalence of diabetes underscores the urgent need for non-invasive, rapid, and cost-effective diagnostic alternatives. This study presents a breath-based multiclass diabetes classification system leveraging only three gas sensors (CO, alcohol, and acetone) to analyze exhaled breath composition. Methods: Breath samples were collected from 58 participants (22 healthy, 7 prediabetic, and 29 diabetic), with blood glucose levels serving as the reference metric. To enhance classification performance, we introduced a novel biomarker, the alcohol-to-acetone ratio, through a feature engineering approach. Class imbalance was addressed using the Synthetic Minority Over-Sampling Technique (SMOTE), ensuring a balanced dataset for model training. A nested cross-validation framework with 3 outer and 3 inner folds was implemented. Multiple machine learning classifiers were evaluated, with Random Forest and Gradient Boosting emerging as the top-performing models. Results: An ensemble combining both yielded the highest overall performance, achieving an average accuracy of 98.86%, precision of 99.07%, recall of 98.81% and F1 score of 98.87%. These findings highlight the potential of gas sensor-based breath analysis as a highly accurate, scalable, and non-invasive method for diabetes screening. Conclusions: The proposed system offers a promising alternative to blood-based diagnostic approaches, paving the way for real-world applications in point-of-care diagnostics and continuous health monitoring.

1 January 2019 in Mathematical Problems in Engineering
Verified
Journal Article
Open access
PDF file
GOG. Obregón-Pulido
G. Obregón-Pulido
Gualberto Solis-PeralesGualberto Solis-Perales
Gualberto Solis-Perales
Jesus Alberto Meda-CampañaJesus Alberto Meda-Campaña
Jesus Alberto Meda-Campaña
GVG. A. Vega-Gómez
G. A. Vega-Gómez
Eduardo Ruiz VelázquezEduardo Ruiz Velázquez
Eduardo Ruiz Velázquez
A design of an adaptive controller applied to the boost and buck‐boost converters to deal with the problem of tracking a sinusoidal voltage is proposed. The main contribution is to provide conditions on the design procedure in order to obtain a reduction in the DC voltage (offset of the sinusoidal signal) of the reference signal; in this way the AC energy is maximized. A nonlinear stable system is designed in order to produce the necessary inputs to exactly track the inductor reference current, which is a necessary condition to achieve the tracking behavior of the voltage reference signal f(t) = A + Bsin⁡(wt). A numerical example is provided to corroborate the result.

11 June 2026 in AI
Verified
Journal Article
Open access
PDF file
Alberto Gudiño-OchoaAlberto Gudiño-Ochoa
Alberto Gudiño-Ochoa
Eduardo Ruiz VelázquezEduardo Ruiz Velázquez
Eduardo Ruiz Velázquez
Julio Alberto García-RodríguezJulio Alberto García-Rodríguez
Julio Alberto García-Rodríguez
Raquel Ochoa OrnelasRaquel Ochoa Ornelas
Raquel Ochoa Ornelas
Sofia Uribe-ToscanoSofia Uribe-Toscano
Sofia Uribe-Toscano
Non-invasive blood glucose estimation from exhaled breath has been proposed as a painless alternative to repeated capillary measurements; however, performance evaluation remains challenging in small-sample settings. This study investigates the estimation of blood glucose from human breath using volatile organic compound (VOC) signals acquired with an electronic nose. Responses from three metal-oxide sensor channels sensitive to CO, alcohol, and acetone were collected from 58 individuals, with one measurement per subject, and analyzed using strictly patient-level five-fold cross-validation, in which test folds comprised only real subjects. Two experimental factors were examined. First, model performance was evaluated with and without an additional interpretable alcohol–acetone log-ratio capturing relative variation between compounds. Second, model training was performed using either real data only or fold-wise tabular synthetic augmentation generated via a Gaussian copula fitted exclusively on training subjects, while evaluation remained strictly real-only. Under real-only training, classical machine learning models achieved the lowest prediction errors (approximately 6–7 mg/dL), whereas under synthetic augmentation FTTransformer was the best-performing deep learning model. This findings should be understood as a constrained proof-of-concept analysis rather than as evidence of diagnostic capability or clinical readiness.

2 June 2023 in Biomedical Signal Processing and Control
Verified
Journal Article
Closed access
CFClaudia Patricia Flores-Gutiérrez
Claudia Patricia Flores-Gutiérrez
GQGriselda Quiroz-Compean
Griselda Quiroz-Compean
OROctavio Rentería-Vidales
Octavio Rentería-Vidales
LTLuis Torres-Treviño
Luis Torres-Treviño
Eduardo Ruiz VelázquezEduardo Ruiz Velázquez
Eduardo Ruiz Velázquez
RFRicardo Femat
Ricardo Femat