Ultra-High-Performance Concrete (UHPC) jacketing is an effective and innovative strengthening method in the renovation projects of concrete bridges. In December 2021, the UHPC-jacketing method was first applied to rehabilitate a seriously damaged bridge in the Changzhou Bridge rehabilitation project in Guangzhou, China. However, the interfacial shear behavior between the Normal Reinforced Concrete (NRC) substrate and UHPC is a crucial factor for the effectiveness of the UHPC-jacketing strengthening method. Therefore, four push-out specimens were designed in this paper to investigate the effects of the embedded bolt diameter (12 mm and 16 mm) and construction method (cast-in-place UHPC layer (ZJ group) and precast UHPC panels with infilled high-strength mortar (GJ group)) on the shear behavior of the NRC–UHPC interface. The results indicated that with the increased bolt diameter from 12 mm to 16 mm, the first peak load (P1) rose from 920.17 kN to 1048.07 kN (+13.9%) in the ZJ group and from 838.08 kN to 1204.20 kN (+43.7%) in the GJ group. The residual loads (Pr) of the GJ group were smaller than those of the ZJ group, at 41.9% and 30.2% lower for bolt diameters of 12 mm and 16 mm, respectively. The construction method of high-strength mortar filling was significantly influenced by the bolt diameter, with a diameter of 16 mm required to fully utilize its shear resistance. Predictions from ACI 318-19 underestimated experimental shear capacity by 70.6% on average, while AASHTO (2017) and Fib provided accurate estimations (within 9.8–10.9% of experimental values).
26 November 2025 in Construction and Building Materials
Steel–ultra-high-performance concrete (UHPC) composite beams with small-rib-height perfobond strip connectors (SRHPBLs) exhibited advantages of light weight and high bearing capacity, demonstrating the potential for applications of UHPC in bridge engineering. During service stages, the composite beams were usually under combined tension–shear loads, rather than pure shear loads. Nevertheless, there were research gaps in the static behavior of SRHPBLs embedded in UHPC under combined tension–shear loads, which limited their applications in practice. To address this issue, systematic experimental and theoretical analyses were conducted in the present study, considering the test variables of tension–shear ratio, row number, and strip number. It was demonstrated that the tension–shear ratio had less effect on ultimate shear strength, initial shear stiffness, and ultimate slip of SRHPBLs. When the tension–shear ratio was increased from 0 to 0.42, the shear capacity, initial shear stiffness, and slip at peak load of SRHPBLs decreased by 24.31%,19.02%, and 22.00%, respectively. However, increasing the row number and strip number significantly improved the shear performance of SRHPBLs. Compared to the single-row specimens, the shear capacity and initial shear stiffness of the three-row specimens increased by an average of 92.82% and 48.77%, respectively. The shear capacity and initial shear stiffness of the twin-strip specimens increased by an average of 103.84% and 87.80%, respectively, compared to the single-strip specimens. Finally, more accurate models were proposed to predict the shear–tension relationship and ultimate shear capacity of SRHPBLs embedded in UHPC under combined tension–shear loads.