Ryota Sayama

Mr. Ryota Sayama

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 February 2026 in Prosthesis
Verified
Journal Article
Open access
PDF file
Ryota SayamaRyota Sayama
Ryota Sayama
YAYukio Agarie
Yukio Agarie
HSHironori Suda
Hironori Suda
HOHiroshi Otsuka
Hiroshi Otsuka
KOKengo Ohnishi
Kengo Ohnishi
SYShinichiro Yamamoto
Shinichiro Yamamoto
Background: Accurate evaluation of pressure distribution at the socket–limb interface is essential for improving prosthetic fit and comfort in transfemoral amputees. This study aimed to develop a proof-of-concept framework that integrates machine learning–based segmentation with the finite element method (FEM) to explore the feasibility of an initial workflow for residual-limb analysis during socket application. Methods: MRI data from a transfemoral amputee were processed using a custom image segmentation algorithm to extract adipose tissue, femur, and ischium, achieving high F-measure scores. The segmented tissues were reconstructed into 3D models, refined through outlier removal and surface smoothing, and used for FEM simulations in LS-DYNA. Pressure values were extracted at nine sensor locations and compared with experimental measurements to provide a preliminary qualitative assessment of model behaviour. Results: The results showed consistent polarity between measured and simulated values across all points. Moderate correspondence was observed at eight low-pressure locations, whereas a substantial discrepancy occurred at the ischial tuberosity (IS), the primary load-bearing site. This discrepancy likely reflects the combined influence of geometric deviation in the reconstructed ischium and the non-physiological medial boundary condition required to prevent unrealistic tissue displacement. This limitation indicates that the current formulation does not support reliable quantitative interpretation at clinically critical locations. Conclusions: Overall, the proposed framework provides an initial demonstration of the methodological feasibility of combining automated anatomical modeling with FEM for exploratory pressure evaluation, indicating that such an integrated pipeline may serve as a useful foundation for future development. While extensive refinement and validation are required before any quantitative or clinically meaningful application is possible, this work represents an early step toward more advanced computational investigations of transfemoral socket–limb interaction.

12 December 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
Ryota SayamaRyota Sayama
Ryota Sayama
YAYukio Agarie
Yukio Agarie
HSHironori Suda
Hironori Suda
HOHiroshi Otsuka
Hiroshi Otsuka
KOKengo Ohnishi
Kengo Ohnishi
SYShinichiro Yamamoto
Shinichiro Yamamoto
Accurate evaluation of pressure distribution at the socket–limb interface is essential for improving prosthetic fit and comfort in transfemoral amputees. This study aimed to develop a data-driven framework that integrates machine learning–based segmentation with finite element method (FEM) to quantitatively assess interface pressure during socket application. MRI data from a transfemoral amputee were processed using a custom image segmentation algorithm to extract adipose tissue, femur, and ischium, achieving high F-measure scores. The segmented tissues were reconstructed into 3D models, refined through outlier removal and surface smoothing, and used for FEM simulations in LS-DYNA. Pressure values were extracted at nine sensor locations and compared with experimental measurements. The results showed consistent polarity between measured and simulated values across all points. Furthermore, at the eight locations excluding the ischial tuberosity (IS) region, a statistically significant and moderately strong positive correlation was observed between measured and simulated pressures (r = 0.7485, p < 0.05). Notably, positive pressure regions demonstrated close agreement between experimental and simulated values, whereas the discrepancy observed at the IS region was likely influenced by the medial boundary conditions introduced to prevent unrealistic tissue displacement. This difference highlights a limitation of the current simulation setup. Overall, the proposed framework demonstrated reliable pressure estimation and offers a promising approach for personalized prosthetic socket design through automated anatomical modeling and simulation.