Effective noise elimination is essential for ensuring data reliability in high-accuracy measurement systems. However, selecting the optimal denoising strategy for diverse and non-stationary signal types remains a major challenge. This study presents a wavelet-based denoising optimization framework that systematically identifies and applies the most suitable noise reduction model for each signal segment. By evaluating multiple wavelet types and thresholding strategies, the proposed method enables adaptive and automated selection tailored to the specific characteristics of each signal. The framework was validated using synthetic, open-access, and experimentally acquired signals in both reference-based and reference-free scenarios. Extensive testing covered signals from power quality disturbance (PQD) events, electrocardiogram (ECG) data, and electroencephalogram (EEG) recordings, all of which represent critical applications where signal integrity under noise is essential. The method achieved optimal model selection in 22.15 s (across 4558 iterations) on a standard PC, with an average denoising time of 4.86 ms per signal window. These results highlight its potential for real-time and embedded applications, including smart grid monitoring systems, wearable health devices, and automated biomedical diagnostic platforms, where adaptive, fast, and reliable denoising is vital. The framework’s versatility makes it highly relevant for deployment in smart grid monitoring systems and intelligent energy infrastructures requiring robust signal conditioning.
19 March 2025 in International Journal of Hydrogen Energy
It is now known that disturbing light flicker originates not only solely from amplitude modulation (AM) of the fundamental amplitude and low-frequency interharmonic components as described in IEC 61000-4-15 standard but also high-frequency interharmonic components around an odd harmonic which have the same effect as low-frequency components causing flicker. Because this effect cannot be detected by the IEC flickermeter, an effective flickermeter is required In this article, a new flickermeter detects both the low- and high-frequency components robustly has been suggested. Quite close responses to those in the IEC model have been obtained in the tests with low-frequency components that have single or multiple amplitudes- and frequencies- interharmonics, and thus a flicker curve with instantaneous flicker sensation value Smax=1 according to the interharmonic-signal model is also proposed. The proposed method employs Voltage Peak Detection (VPD) instead of Root Mean Square (RMS) for flicker computation, taking the advantage of the fact that the new generation lamps such as CFLs and LEDs are insensitive to phase angle shifts in contrast to the incandescent lamps.