Sıtkı AKKAYA

Dr. Sıtkı AKKAYA

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 January 2024 in Electrical Engineering
Verified
Journal Article
Closed access
PDF file
Sıtkı AKKAYASıtkı AKKAYA
Sıtkı AKKAYA
EYEmre Yüksek
Emre Yüksek
HAHasan Metehan Akgün
Hasan Metehan Akgün

1 September 2025 in Ain Shams Engineering Journal
Verified
Journal Article
Open access
Sıtkı AKKAYASıtkı AKKAYA
Sıtkı AKKAYA
SDSezer Dümen
Sezer Dümen

11 August 2025 in Electronics
Verified
Journal Article
Open access
PDF file
Sıtkı AKKAYASıtkı AKKAYA
Sıtkı AKKAYA
Effective noise elimination is essential for ensuring data reliability in high-accuracy measurement systems. However, selecting the optimal denoising strategy for diverse and non-stationary signal types remains a major challenge. This study presents a wavelet-based denoising optimization framework that systematically identifies and applies the most suitable noise reduction model for each signal segment. By evaluating multiple wavelet types and thresholding strategies, the proposed method enables adaptive and automated selection tailored to the specific characteristics of each signal. The framework was validated using synthetic, open-access, and experimentally acquired signals in both reference-based and reference-free scenarios. Extensive testing covered signals from power quality disturbance (PQD) events, electrocardiogram (ECG) data, and electroencephalogram (EEG) recordings, all of which represent critical applications where signal integrity under noise is essential. The method achieved optimal model selection in 22.15 s (across 4558 iterations) on a standard PC, with an average denoising time of 4.86 ms per signal window. These results highlight its potential for real-time and embedded applications, including smart grid monitoring systems, wearable health devices, and automated biomedical diagnostic platforms, where adaptive, fast, and reliable denoising is vital. The framework’s versatility makes it highly relevant for deployment in smart grid monitoring systems and intelligent energy infrastructures requiring robust signal conditioning.

19 March 2025 in International Journal of Hydrogen Energy
Verified
Journal Article
Closed access
MGMehmet Güçyetmez
Mehmet Güçyetmez
Sıtkı AKKAYASıtkı AKKAYA
Sıtkı AKKAYA
MUMurat Uyar
Murat Uyar
Şekip Esat HayberŞekip Esat Hayber
Şekip Esat Hayber


21 April 2021 in Electric Power Components and Systems
Verified
Journal Article
Closed access
Sıtkı AKKAYASıtkı AKKAYA
Sıtkı AKKAYA
ÖSÖzgül Salor
Özgül Salor
It is now known that disturbing light flicker originates not only solely from amplitude modulation (AM) of the fundamental amplitude and low-frequency interharmonic components as described in IEC 61000-4-15 standard but also high-frequency interharmonic components around an odd harmonic which have the same effect as low-frequency components causing flicker. Because this effect cannot be detected by the IEC flickermeter, an effective flickermeter is required In this article, a new flickermeter detects both the low- and high-frequency components robustly has been suggested. Quite close responses to those in the IEC model have been obtained in the tests with low-frequency components that have single or multiple amplitudes- and frequencies- interharmonics, and thus a flicker curve with instantaneous flicker sensation value Smax=1 according to the interharmonic-signal model is also proposed. The proposed method employs Voltage Peak Detection (VPD) instead of Root Mean Square (RMS) for flicker computation, taking the advantage of the fact that the new generation lamps such as CFLs and LEDs are insensitive to phase angle shifts in contrast to the incandescent lamps.