Şekip Esat Hayber

Dr. Şekip Esat Hayber

Department of Electrical-Electronics Engineering, Bursa Uludağ University, Bursa, Turkey (Türkiye)
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 October 2018 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
Şekip Esat HayberŞekip Esat Hayber
Şekip Esat Hayber
TTTimuçin Emre Tabaru
Timuçin Emre Tabaru
SKSerkan Keser
Serkan Keser
OSOmer Galip Saracoglu
Omer Galip Saracoglu
We present a high sensitive Fiber-Optic Microphone (FOM) with a wide measuring range based on a cellulose triacetate diaphragm in this work. The average Signal to Noise Ratio (SNR) of the proposed FOM is measured 50.86 dB in at the frequency range of 100 Hz-20 kHz. In the same spectrum range, the highest SNR for the 2 kHz frequency under 103.16 mPa acoustic pressure is measured at 72.20 dB with 2 Hz resolution bandwidth, which corresponds to a noise-limited minimum detectable acoustic pressure level of 17.91 μPa/ $\sqrt$ Hz. The proposed sensor has advantages of high sensitivity, low cost, and easy fabrication. According to the assessments based on the obtained results, the FOM can be used for medical spectroscopy, imaging applications and for long-distance listening and voice recognition in the military-public security.

1 December 2021 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
SKSerkan Keser
Serkan Keser
Şekip Esat HayberŞekip Esat Hayber
Şekip Esat Hayber

1 July 2020 in Optical Fiber Technology
Verified
Journal Article
Closed access
Şekip Esat HayberŞekip Esat Hayber
Şekip Esat Hayber
SKSerkan Keser
Serkan Keser

9 December 2016 in Sensors
Verified
Journal Article
Open access
PDF file
OSOmer Galip Saracoglu
Omer Galip Saracoglu
Şekip Esat HayberŞekip Esat Hayber
Şekip Esat Hayber
A fiber optic sensor sensitive to refractive index changes of the outer region of the fiber cladding is presented. The sensor uses bent plastic optical fibers in different bending lengths to increase sensitivity. Measurements were made for low-fat milk, the refractive index of which is altered by some preservatives such as formaldehyde, hydrogen peroxide, and sodium carbonate. Concentrations of the preservatives in the milk were changed between 0% and 14.3% while the refractive indices occurred between 1.34550 and 1.35093 for the minimum (0%) and maximum (14.286%) concentrations of sodium carbonate, respectively. Due to bending-induced sensitivity, the sensor is able to detect refractive index changes less of than 0.4%. The results show that there is excellent linearity between the concentration and normalized response of the sensor.

1 January 2019 in Optics Communications
Verified
Journal Article
Closed access
Şekip Esat HayberŞekip Esat Hayber
Şekip Esat Hayber
TTTimuçin Emre Tabaru
Timuçin Emre Tabaru
OSOmer Galip Saracoglu
Omer Galip Saracoglu

2 November 2021 in Fiber and Integrated Optics
Verified
Journal Article
Closed access
Şekip Esat HayberŞekip Esat Hayber
Şekip Esat Hayber
TTTimuçin Emre Tabaru
Timuçin Emre Tabaru
MGMehmet Güçyetmez
Mehmet Güçyetmez
Observing the transformer oil quality is essential for the transformer’s health and system. The aging state of the transformer oils and the average remaining life accordingly can be determined using the breakdown voltage (BDV) test, ultraviolet-visible (UV-Vis) spectroscopy, and the refractive index (RI) standard methods. The subject of this study is to design and manufacture a much simpler and low-cost, evanescent field absorption-based fiber optic sensor (EFA-FOS) compatible with these proven standard methods and to perform a comparative performance analysis by determining a critical voltage threshold. Apart from the expensive and cumbersome standard methods mentioned above, the usability of the oil is carried out, thanks to the online sensor system, with the pretest using this critical voltage value. EFA-FOS measurement results of oil samples can determine the samples’ aging degree with high accuracy. The samples’ RI is determined with EFA-FOS with a sensitivity of −70 V/RIU and a linearity of 0.98 (R2). A strong relationship has also been determined between the sensor output and measured BDV with a regression constant of 0.86 (R2). Graphical Abstract