Saad Dilshad

Dr. Saad Dilshad

Department of Electrical Engineering, University of Management and Technology, Lahore, Punjab, Pakistan
orcid
PhD in Electrical Engineering | Renewable Energy Integration...

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 January 2020 in International Journal of Energy Research
Verified
Journal Article
Closed access
PDF file
Muhammad Abdul BasitMuhammad Abdul Basit
Muhammad Abdul Basit
Saad DilshadSaad Dilshad
Saad Dilshad
RBRabiah Badar
Rabiah Badar
SRSyed Muhammad Sami Ur Rehman
Syed Muhammad Sami Ur Rehman

18 March 2019 in Energy Storage
Verified
Journal Article
Closed access
PDF file
NKNASRULLAH KHAN
NASRULLAH KHAN
Saad DilshadSaad Dilshad
Saad Dilshad
RKRashida Khalid
Rashida Khalid
AKAli Raza Kalair
Ali Raza Kalair
NANaeem Abas
Naeem Abas

7 September 2020 in IEEE Access
Verified
Journal Article
Open access
NANaeem Abas
Naeem Abas
Saad DilshadSaad Dilshad
Saad Dilshad
AKAdnan Khalid
Adnan Khalid
MSMuhammad Shoaib Saleem
Muhammad Shoaib Saleem
NKNasrullah Khan
Nasrullah Khan
Power Quality is an essential concern in the modern power system that can affect consumers and utility. The integration of renewable energy sources, smart grid systems and extensive use of power electronics equipment caused myriad problems in the modern electric power system. Current and voltage harmonics, voltage sag, and swell can damage the sensitive equipment. These devices are susceptible to input voltage variations created by interference with other parts of the system. Hence, in the modern age, with an increase in sensitive and expensive electronic equipment, power quality is essential for the power system’s reliable and safe operation. Dynamic Voltage Restorer (DVR) is a potential Distribution Flexible AC Transmission System (D-FACTS) device widely adopted to surmount the problems of non-standard voltage, current, or frequency in the distribution grid. It injects voltages in the distribution line to maintain the voltage profile and assures constant load voltage. The simulations were conducted in MATLAB/Simulink to show the DVR-based proposed strategy’s effectiveness to smooth the distorted voltage due to harmonics. A power system model with a programmable power source is used to include 3rd and 5th harmonics. The systems’ response for load voltage is evaluated for with and without DVR scenarios. It has been noted that the proposed DVR based strategy has effectively managed the voltage distortion, and a smooth compensated load voltage was achieved. The load voltage THD percentage was approximately 18% and 23% with insertion 3rd and 5th harmonics in the supply voltage, respectively. The inclusion of the proposed DVR has reduced THD around less than 4% in both cases.

12 December 2019 in International Journal of Energy Research
Verified
Journal Article
Closed access
PDF file
Saad DilshadSaad Dilshad
Saad Dilshad
AKAli Raza Kalair
Ali Raza Kalair
NKNASRULLAH KHAN
NASRULLAH KHAN

1 August 2021 in Case Studies in Thermal Engineering
Verified
Journal Article
Open access
ARAreeba Rahman
Areeba Rahman
NANaeem Abas
Naeem Abas
Saad DilshadSaad Dilshad
Saad Dilshad
MSMuhammad Shoaib Saleem
Muhammad Shoaib Saleem

4 June 2024 in Results in Engineering
Verified
Journal Article
Open access
MUMuhammad Umer
Muhammad Umer
NANaeem Abas
Naeem Abas
SRShoaib Rauf
Shoaib Rauf
MSMuhammad Shoaib Saleem
Muhammad Shoaib Saleem
Saad DilshadSaad Dilshad
Saad Dilshad