This paper presents a statistical algorithm for classification of fault causes on power transmission lines. The proposed algorithm is based upon the root mean square (RMS) current duration, voltage dip, and discrete wavelet transform (DWT) measured at the sending end of a line and the decision tree method, a commonly accessible measurable method. Fault duration of RMS current signal, voltage dip, and DWT gives concealed data of a fault signature as a contribution to decision tree calculation which is utilized to classify various fault causes. The proposed method was carried out in the MATLAB/SIMULINK programming platform based upon the information made with the fault analysis of the 275 kV sample transmission line considering wide variations in the operating conditions. The classifier performance of different parameters was also compared in a confusion matrix form to obtain the best classification results of the decision tree.
An auto-restoration tool to minimize the impact of faults is one of the critical requirements in a power distribution system. A fault-monitoring system is needed for practical remote supervision to identify faults and reduce their impacts, and thus reduce economic losses. An effective fault-monitoring system is beneficial to improve the reliability of a protection system when faults evolve. Therefore, fault monitoring could play an important role in enhancing the safety standards of systems. Among the various fault occurrences, the transient fault is a prominent cause in Malaysia power systems but gains less attention due to its ability of self-clearance, although sometimes it unnecessarily triggers the operation of protection systems. However, the transient fault is an issue that must be addressed based on its effect that can lead to outages and short-circuits if prolonged. In this study, the authors summarize the guidelines and related standards of fault interaction associated with a monitoring system. The necessity of transient fault detection and location techniques and their limitations, the need for signal processing, as well as recommended practices, are also discussed in this paper. Some of the practices from local power utility are also shared, indicating the current approaches, key challenges, and the opportunities for improvement of fault-monitoring systems due to transient fault, which can be correlated with the reviews provided.
Solar photovoltaic (PV) panels performance is influenced by various external factors such as precipitation, wind angle, ambient temperature, wind speed, transient irradiation, and soil deposition. Soiling accumulation on panels poses a significant challenge to PV power generation. This paper presents the development of an artificial neural network (ANN)-based soil deposition prediction model for PV systems. Conducted at a Malaysian solar farm over three months, the research utilized power output data from the inverter as model output and meteorological data as input variables. The model employed the Levenberg-Marquardt backpropagation method with Tansig and Purline activation functions. Performance assessment via statistical comparison of experimental and simulated results revealed a coefficient of determination (R2) value of 0.68073 for the ANN architecture of 5 input layers, 30 hidden layers, and 1 output layer (5-30-1). Sensitivity analysis highlighted relative humidity and wind direction as the most influential parameters affecting PV soiling rate. The developed ANN model, combined with sensitivity analysis, serves as a robust foundation for enhancing the efficiency of smart sensors in PV module cleaning systems.
1 December 2024 in International Journal of Advances in Applied Sciences
In recent years, the relationship between a country's gross domestic product (GDP) and its electricity consumption has changed significantly due to increased energy efficiency (EE) and renewable energy (RE) adoption. This decoupling disrupts conventional load forecasting models, affecting utility companies. This study has developed an innovative solution using an artificial neural network (ANN) Hybrid method for load forecasting, resulting in a remarkably accurate model with 99.68% precision. Applying this model to Malaysia's electricity consumption from 2020 to 2040 reveals a significant 13% reduction when accounting for EE and RE trends. This method aids risk management, contingency planning, and decision-making by accurately reflecting changing energy usage dynamics influenced by EE and RE sources.