Sajid Hussain Qazi

Dr. Sajid Hussain Qazi

Electromechanical and System Engineering, Ghent University, Ghent, Belgium
orcid
BESS Expert

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2016 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Closed access
Sajid Hussain QaziSajid Hussain Qazi
Sajid Hussain Qazi
MMMohd Wazir Mustafa
Mohd Wazir Mustafa

22 May 2018 in Energies
Verified
Journal Article
Open access
PDF file
Sajid Hussain QaziSajid Hussain Qazi
Sajid Hussain Qazi
MMMohd Wazir Mustafa
Mohd Wazir Mustafa
USUmbrin Sultana
Umbrin Sultana
NMNayyar Hussain Mirjat
Nayyar Hussain Mirjat
SAShakir Ali
Shakir Ali
NRNadia Rasheed
Nadia Rasheed
This study explores the Whales Optimization Algorithm (WOA)-based PI controller for regulating the voltage and frequency of an inverter-based autonomous microgrid (MG). The MG comprises two 50 kW DGs (solid oxide fuel cells, SOFCs) interfaced using a power electronics-based voltage source inverter (VSI) with a 120-kV conventional grid. Four PI controller schemes for the MG are implemented: (i) stationary PI controller with fixed gain values (Kp and Ki), (ii) PSO tuned PI controller, (iii) GWO tuned PI controller, and (iv) WOA tuned PI controller. The performance of these controllers is evaluated by monitoring the system voltage and frequency during the transition of MG operation mode and changes in the load. The MATLAB/SIMULINK tool is utilised to design the proposed model of grid-tied MG alongside the MATLAB m-file to apply an optimisation technique. The simulation results show that the WOA-based PI controller which optimises the control parameters, achieve 62.7% and 59% better results for voltage and frequency regulation, respectively. The eigenvalue analysis is also provided to check the stability of the proposed controller. Furthermore, the proposed system also satisfies the limits specified in IEEE-1547-2003 for voltage and frequency.

16 June 2025 in Batteries
Verified
Journal Article
Open access
PDF file
Sajid Hussain QaziSajid Hussain Qazi
Sajid Hussain Qazi
MDMARVI DASHI
MARVI DASHI
DBDimitar Bozalakov
Dimitar Bozalakov
Lieven VandeveldeLieven Vandevelde
Lieven Vandevelde
Integrating offshore renewable energy (ORE) into power systems is vital for sustainable energy transitions. This paper examines the challenges and opportunities in integrating ORE, focusing on offshore wind and floating solar, into grid systems. A simulation was conducted using a 5 MW offshore wind turbine and a 2 MW floating PV (FPV) system, complemented by a 10 MWh battery energy storage system (BESS). The simulation utilized the typical load profile of Belgium and actual 2023 electricity price data, along with realistic wind and solar generation patterns for a location at the sea border of Belgium and the Netherlands. The use of real operational and market data ensures the practical relevance of the results. This study highlights the importance of BESS, targeting a significant revenue by participating in system imbalance and providing ancillary services (aFRR and mFRR). Key findings emphasize the need for grid infrastructure transformation to support ORE’s growing investments and deployment. This research underscores the essential role of technological innovation and strategic planning in optimizing the potential of ORE sources.

13 May 2024 in Frontiers in Energy Research
Verified
Journal Article
Open access
Sajid Hussain QaziSajid Hussain Qazi
Sajid Hussain Qazi
DBDimitar V. Bozalakov
Dimitar V. Bozalakov
Lieven VandeveldeLieven Vandevelde
Lieven Vandevelde
In this research, the performance of vanadium redox flow batteries (VRFBs) in grid-connected energy storage systems centering on frequency and power sharing using voltage source inverters was evaluated. VRFBs are increasingly promising due to their scalability and long lifespan. We explore the impact of voltage source inverters on the frequency of the power supply when there is a change in load and power sharing between the grid and VRFB through MATLAB simulations. The test system demonstrates a storage system at an 11-kV substation and considers a load profile commencing from residential and commercial consumers. The outcome of this study reveals that VRFBs provide the required power to maintain load demand. Due to fast response time, VRFBs also regulate the frequency efficiently during the change in load demand and maintaining current total harmonic distortions (THDs). This research confirms the design and operation of VRFB-based energy storage systems, contributing to resilient grid infrastructure and reliable power distribution systems.

1 May 2017 in Indian Journal of Science and Technology
Verified
Journal Article
Open access
PDF file
Sajid Hussain QaziSajid Hussain Qazi
Sajid Hussain Qazi
MMM. W. Mustafa
M. W. Mustafa
USUmbrin Sultana
Umbrin Sultana
NHNayyar Hussain
Nayyar Hussain
Enhanced Power Quality Controller in an Autonomous Microgrid by PSO Tuned PI Controller

3 June 2025 in International Journal of Electrical Power & Energy Systems
Verified
Journal Article
Open access
DBDimitar Bozalakov
Dimitar Bozalakov
Sajid Hussain QaziSajid Hussain Qazi
Sajid Hussain Qazi
JKJeroen D.M. De Kooning
Jeroen D.M. De Kooning
Lieven VandeveldeLieven Vandevelde
Lieven Vandevelde