Saqib Rashid

Dr. Saqib Rashid

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 July 2022 in Materials & Design
Verified
Journal Article
Open access
FBFrancesco Bignoli
Francesco Bignoli
SRSaqib Rashid
Saqib Rashid
Edoardo RossiEdoardo Rossi
Edoardo Rossi
SJSahar Jaddi
Sahar Jaddi
PDPhilippe Djemia
Philippe Djemia
MGMatteo Ghidelli
Matteo Ghidelli

9 February 2021 in Nanomaterials
Verified
Journal Article
Open access
PDF file
SRSaqib Rashid
Saqib Rashid
Marco SebastianiMarco Sebastiani
Marco Sebastiani
MMMuhammad Zeeshan Mughal
Muhammad Zeeshan Mughal
RDRostislav Daniel
Rostislav Daniel
EBEdoardo Bemporad
Edoardo Bemporad
In this work, the ternary titanium, copper, and silver (Ti-Cu-Ag) system is investigated as a potential candidate for the production of mechanically robust biomedical thin films. The coatings are produced by physical vapor deposition—magnetron sputtering (MS-PVD). The composite thin films are deposited on a silicon (100) substrate. The ratio between Ti and Cu was approximately kept one, with the variation of the Ag content between 10 and 35 at.%, while the power on the targets is changed during each deposition to get the desired Ag content. Thin film characterization is performed by X-ray diffraction (XRD), nanoindentation (modulus and hardness), to quantitatively evaluate the scratch adhesion, and atomic force microscopy to determine the surface topography. The residual stresses are measured by focused ion beam and digital image correlation method (FIB-DIC). The produced Ti-Cu-Ag thin films appear to be smooth, uniformly thick, and exhibit amorphous structure for the Ag contents lower than 25 at.%, with a transition to partially crystalline structure for higher Ag concentrations. The Ti-Cu control film shows higher values of 124.5 GPa and 7.85 GPa for modulus and hardness, respectively. There is a clear trend of continuous decrease in the modulus and hardness with the increase of Ag content, as lowest value of 105.5 GPa and 6 GPa for 35 at.% Ag containing thin films. In particular, a transition from the compressive (−36.5 MPa) to tensile residual stresses between 229 MPa and 288 MPa are observed with an increasing Ag content. The obtained results suggest that the Ag concentration should not exceed 25 at.%, in order to avoid an excessive reduction of the modulus and hardness with maintaining (at the same time) the potential for an increase of the antibacterial properties. In summary, Ti-Cu-Ag thin films shows characteristic mechanical properties that can be used to improve the properties of biomedical implants such as Ti-alloys and stainless steel.

Verified
Journal Article
Open access
PDF file
SRSaqib Rashid
Saqib Rashid
Edoardo RossiEdoardo Rossi
Edoardo Rossi
SDSpyridon Diplas
Spyridon Diplas
PCPatricia Almeida Carvalho
Patricia Almeida Carvalho
DPDamian Pucicki
Damian Pucicki
Marco SebastianiMarco Sebastiani
Marco Sebastiani
Residual stresses in multilayer thin coatings represent a complex multiscale phenomenon arising from the intricate interplay of multiple factors, including the number and thickness of layers, material properties of the layers and substrate, coefficient of thermal expansion (CTE) mismatch, deposition technique and growth mechanism, as well as process parameters and environmental conditions. A multiscale approach to residual stress measurement is essential for a comprehensive understanding of stress distribution in such systems. To investigate this, two AlGaN/GaN multilayer coatings with distinct layer architectures were deposited on sapphire substrates using metalorganic vapor phase epitaxy (MOVPE). High-resolution X-ray diffraction (HRXRD) was employed to confirm their epitaxial growth and structural characteristics. Focused ion beam (FIB) cross-sectioning and transmission electron microscopy (TEM) lamella preparation were performed to analyze the coating structure and determine layer thickness. Residual stresses within the multilayer coatings were evaluated using two complementary techniques: High-Resolution Scanning Transmission Electron Microscopy—Graphical Phase Analysis (HRSTEM-GPA) and Focused Ion Beam—Digital Image Correlation (FIB-DIC). HRSTEM-GPA enables atomic-resolution strain mapping, making it particularly suited for investigating interface-related stresses, while FIB-DIC facilitates microscale stress evaluation. The residual strain values obtained using the FIB-DIC and HRSTEM-GPA methods were −3.2 × 10⁻3 and −4.55 × 10⁻3, respectively. This study confirms that residual stress measurements at different spatial resolutions are both reliable and comparable at the required coating depths and locations, provided that a critical assessment of the characteristic scale of each method is performed.

24 June 2021 in Preprints.org
Verified
Preprint
Open access
SRSaqib Rashid
Saqib Rashid
GVGian Marco Vita
Gian Marco Vita
Luca PersichettiLuca Persichetti
Luca Persichetti
GIGiovanna Iucci
Giovanna Iucci
CBChiara Battocchio
Chiara Battocchio
Alessandra Di MasiAlessandra Di Masi
Alessandra Di Masi
Mechanical robustness, biocompatibility, and antibacterial performances are key features for materials suitable to be used in tissue engineering applications. In this work, we investigated the link existing between structural and functional properties of TiCu(Ag) thin films deposited by physical vapor deposition magnetron sputtering on Si substrates. The thin films were characterized by X-ray diffraction (XRD), nanoindentation, atomic force microscopy (AFM), and X-ray photoelectron spectroscopy (XPS). The TiCu(Ag) thin films showed complete amorphous structure and improved mechanical properties in comparison with pure Ti films. However, for contents in excess of 20% Ag, we observed the appearance of nanometric Ag crystallite. The TiCu(Ag) thin films displayed excellent biocompatibility properties, allowing adhesion and proliferation of the human fibroblasts MRC-5 cell line. Moreover, all the investigated TiCu(Ag) alloy display bactericidal properties, preventing the growth of both Pseudomonas aeruginosa and Staphylococcus aureus. Results obtained from biological tests have been correlated to the surface structure and microstructure of films. The excellent biocompatibility and bactericidal properties of these multifunctional thin films opens to their use in tissue engineering applications.

15 April 2026 in Sensors and Actuators A: Physical
Verified
Journal Article
Open access
SRSaqib Rashid
Saqib Rashid
EREdoardo Rossi
Edoardo Rossi
PMPaolo Martins
Paolo Martins
RGRaphael Guillemet
Raphael Guillemet
EBEdoardo Bemporad
Edoardo Bemporad
MSMarco Sebastiani
Marco Sebastiani

13 January 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
Edoardo RossiEdoardo Rossi
Edoardo Rossi
SRSaqib Rashid
Saqib Rashid
SDSpyridon Diplas
Spyridon Diplas
PCPatricia Almeida Carvalho
Patricia Almeida Carvalho
DPDamian Pucicki
Damian Pucicki
Marco SebastianiMarco Sebastiani
Marco Sebastiani
Residual stresses in multilayer coatings are indeed a complex phenomenon due to intricate interaction between multiple factors such as layer number and thickness, layer and substrate materials, coefficient of thermal expansion mismatch (CTE), deposition technique, process parameters and deposition environment. The measurement of residual stresses is crucial and for that reason a series of AlGaN/GaN multilayer coatings with different layer structure was produced by metalorganic vapor phase epitaxy (MOVPE) on sapphire substrate. These produced coatings were characterized by high-resolution x-ray diffraction to verify their epitaxial growth and structural properties. The coating structure and layer thicknesses were obtained by performing the FIB cross-section and TEM lamella preparation. The residual stresses within the AlGaN/GaN multilayer coatings were evaluated by two different techniques with different spatial resolution from sub-nano scale to micron level: high-resolution scanning transmission electron microscopy-geometrical phase analysis (HRSTEM-GPA) and focused ion beam-digital image correlation (FIB-DIC). The residual stresses resulting from these techniques (non-destructive and semi-destructive) were critically compared based on variable spatial resolution ranging from sub-micron to sub-nano level, in order to check the reliability and compatibility of both techniques in terms of accuracy and efficiency. This study observes the residual stresses calculated by different spatial resolution techniques are reliable and comparable at required coating depths and locations.