Sara Knezevic

Dr. Sara Knezevic

University of Bordeaux, Bordeaux, Nouvelle-Aquitaine, France
+1
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 June 2024 in Angewandte Chemie International Edition
Verified
Journal Article
Open access
SKSara Knezevic
Sara Knezevic
DHDongni Han
Dongni Han
BLBaohong Liu
Baohong Liu
DJDechen Jiang
Dechen Jiang
Neso SojicNeso Sojic
Neso Sojic
Electrochemiluminescence (ECL) is rapidly evolving from an analytical method into an optical microscopy. The orthogonality of the electrochemical trigger and the optical readout distinguishes it from classic microscopy and electrochemical techniques, owing to its near‐zero background, remarkable sensitivity, and absence of photobleaching and phototoxicity. In this minireview, we summarize the recent advances in ECL imaging technology, emphasizing original configurations which enable the imaging of biological entities and the improvement of the analytical properties by increasing the complexity and multiplexing of bioassays. Additionally, mapping the (electro)chemical reactivity in space provides valuable information on nanomaterials and facilitates deciphering ECL mechanisms for improving their performances in diagnostics and (electro)catalysis. Finally, we highlight the recent achievements in imaging at the ultimate limits of single molecules, single photons or single chemical reactions, and the current challenges to translate the ECL imaging advances to other fields such as material science, catalysis and biology.

1 November 2022 in eScience
Verified
Journal Article
Open access
CMChengda Meng
Chengda Meng
SKSara Knezevic
Sara Knezevic
FDFangxin Du
Fangxin Du
YGYiran Guan
Yiran Guan
FKFrédéric Kanoufi
Frédéric Kanoufi
GXGuobao Xu
Guobao Xu

26 January 2023 in ACS Sensors
Verified
Journal Article
Closed access
EKEmily Kerr
Emily Kerr
SKSara Knezevic
Sara Knezevic
PFPaul S. Francis
Paul S. Francis
CHConor F. Hogan
Conor F. Hogan
GVGiovanni Valenti
Giovanni Valenti
Neso SojicNeso Sojic
Neso Sojic

19 December 2023 in Chemical Science
Verified
Journal Article
Open access
PDF file
AFAlessandro Fracassa
Alessandro Fracassa
CSClaudio Ignazio Santo
Claudio Ignazio Santo
EKEmily Kerr
Emily Kerr
SKSara Knezevic
Sara Knezevic
DHDavid J. Hayne
David J. Hayne
GVGiovanni Valenti
Giovanni Valenti
Electrochemiluminescence (ECL) is a highly sensitive mode of detection utilised in commercialised bead-based immunoassays. Recently, the introduction of a freely diffusing water-soluble Ir(III) complex was demonstrated to enhance the ECL emission of [Ru(bpy)3]2+ labels anchored to microbeads, but a comprehensive investigation of the proposed ‘redox-mediated’ mechanism was not carried out. In this work, we select three different water-soluble Ir(III) complexes by virtue of their photophysical and electrochemical properties in comparison with those of the [Ru(bpy)3]2+ luminophore and the TPrA co-reactant. A systematic investigation of the influence of each Ir(III) complex on the emission of the Ru(II) labels on single beads by ECL microscopy revealed that the heterogeneous ECL can be finely tuned and either enhanced up to 107% or lowered by 75%. The variation of the [Ru(bpy)3]2+ ECL emission was correlated to the properties of each Ir(III)-based mediator, which enabled us to decipher the mechanism of interaction and define guidelines for the future design of novel Ir(III) complexes to further enhance the ECL emission of bead-based immunoassays. Ultimately, we showcase the potential of this technology for practical sample analysis in commercial instruments by assessing the enhancement of the collective ECL intensity from a bead-based system.

2 August 2024 in Journal of the American Chemical Society
Verified
Journal Article
Open access
SKSara Knezevic
Sara Knezevic
JTJoseba Totoricaguena-Gorriño
Joseba Totoricaguena-Gorriño
RGRajendra Kumar Reddy Gajjala
Rajendra Kumar Reddy Gajjala
BHBruno Hermenegildo
Bruno Hermenegildo
Leire Ruiz-RubioLeire Ruiz-Rubio
Leire Ruiz-Rubio
JCJavier del Campo
Javier del Campo
Electrochemiluminescence (ECL) is typically confined to a micrometric region from the electrode surface. This study demonstrates that ECL emission can extend up to several millimeters away from the electrode employing electrogenerated chlorine bubbles. The mechanism behind this bubble-enhanced ECL was investigated using an Au microelectrode in chloride-containing and chloride-free electrolyte solutions. We discovered that ECL emission at the gas/solution interface is driven by two parallel effects. First, the bubble corona effect facilitates the generation of hydroxyl radicals capable of oxidizing luminol while the bubble is attached to the surface. Second, hypochlorite generated from chlorine sustains luminol emission for over 200 s and extends the emission range up to 5 mm into the solution, following bubble detachment. The new approach can increase the emission intensity of luminol-based assays 5-fold compared to the conventional method. This is demonstrated through a glucose bioassay, using a midrange mobile phone camera for detection. These findings significantly expand the potential applications of ECL by extending its effective range in time and space.

27 June 2022 in Current Opinion in Electrochemistry
Verified
Journal Article
Closed access
SKSara Knezevic
Sara Knezevic
LBLaurent Bouffier
Laurent Bouffier
BLBaohong Liu
Baohong Liu
DJDechen Jiang
Dechen Jiang
Neso SojicNeso Sojic
Neso Sojic