Claudio Ignazio Santo

Claudio Ignazio Santo

Auto-generated profile, based on publicly available information

Claudio Ignazio Santo

Department of Chemistry “Giacomo Ciamician

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 December 2021 in Analytical Chemistry
Verified
Journal Article
Open access
SRSara Rebeccani
Sara Rebeccani
AZAlessandra Zanut
Alessandra Zanut
CSClaudio Ignazio Santo
Claudio Ignazio Santo
GVGiovanni Valenti
Giovanni Valenti
FPFrancesco Paolucci
Francesco Paolucci

19 December 2023 in Chemical Science
Verified
Journal Article
Open access
PDF file
AFAlessandro Fracassa
Alessandro Fracassa
CSClaudio Ignazio Santo
Claudio Ignazio Santo
EKEmily Kerr
Emily Kerr
SKSara Knezevic
Sara Knezevic
DHDavid J. Hayne
David J. Hayne
GVGiovanni Valenti
Giovanni Valenti
Electrochemiluminescence (ECL) is a highly sensitive mode of detection utilised in commercialised bead-based immunoassays. Recently, the introduction of a freely diffusing water-soluble Ir(III) complex was demonstrated to enhance the ECL emission of [Ru(bpy)3]2+ labels anchored to microbeads, but a comprehensive investigation of the proposed ‘redox-mediated’ mechanism was not carried out. In this work, we select three different water-soluble Ir(III) complexes by virtue of their photophysical and electrochemical properties in comparison with those of the [Ru(bpy)3]2+ luminophore and the TPrA co-reactant. A systematic investigation of the influence of each Ir(III) complex on the emission of the Ru(II) labels on single beads by ECL microscopy revealed that the heterogeneous ECL can be finely tuned and either enhanced up to 107% or lowered by 75%. The variation of the [Ru(bpy)3]2+ ECL emission was correlated to the properties of each Ir(III)-based mediator, which enabled us to decipher the mechanism of interaction and define guidelines for the future design of novel Ir(III) complexes to further enhance the ECL emission of bead-based immunoassays. Ultimately, we showcase the potential of this technology for practical sample analysis in commercial instruments by assessing the enhancement of the collective ECL intensity from a bead-based system.

17 March 2022 in ACS Sensors
Verified
Journal Article
Closed access
KSKohei Sakanoue
Kohei Sakanoue
AFAndrea Fiorani
Andrea Fiorani
CSClaudio Ignazio Santo
Claudio Ignazio Santo
IRIrkham
Irkham
GVGiovanni Valenti
Giovanni Valenti
YEYasuaki Einaga
Yasuaki Einaga

1 December 2001 in Polyhedron
Verified
Journal Article
Closed access
LCLuciano Canovese
Luciano Canovese
FVFabiano Visentin
Fabiano Visentin
CSClaudio Santo
Claudio Santo
GCGavino Chessa
Gavino Chessa
PUPaolo Uguagliati
Paolo Uguagliati

22 November 2024 in Chemical & Biomedical Imaging
Verified
Journal Article
Open access
CSClaudio Ignazio Santo
Claudio Ignazio Santo
GCGuillermo Conejo-Cuevas
Guillermo Conejo-Cuevas
FPFrancesco Paolucci
Francesco Paolucci
JCJavier del Campo
Javier del Campo
GVGiovanni Valenti
Giovanni Valenti
Electrochemiluminescence (ECL) is nowadays a powerful technique widely used in biosensing and imaging, offering high sensitivity and specificity for detecting and mapping biomolecules. Screen-printed electrodes (SPEs) offer a versatile and cost-effective platform for ECL applications due to their ease of fabrication, disposability, and suitability for large-scale production. This research introduces a novel method for improving the ECL characteristics of screen-printed carbon electrodes (SPCEs) through the application of CO2 laser treatment following fabrication. Using advanced ECL microscopy, we analyze three distinct carbon paste-based electrodes and show that low-energy laser exposure (ranging from 7 to 12 mJ·cm-2) enhances the electrochemical performance of the electrodes. This enhancement results from the selective removal of surface binders and contaminants achieved by the laser treatment. We employed ECL microscopy to characterize the ECL emission using a bead-based system incorporating magnetic microbeads, like those used in commercial platforms. This approach enabled high-resolution spatial mapping of the electrode surface, offering valuable insights into its electrochemical performance. Through quantitative assessment using a photomultiplier tube (PMT), it was observed that GST electrodes could detect biomarkers with high sensitivity, achieving an approximate detection limit (LOD) of 11 antibodies per μm2. These findings emphasize the potential of laser-modified GST electrodes in enabling highly sensitive electrochemiluminescent immunoassays and various biosensing applications.

1 September 2014 in Inorganica Chimica Acta
Verified
Journal Article
Closed access
LCLuciano Canovese
Luciano Canovese
FVFabiano Visentin
Fabiano Visentin
CSClaudio Santo
Claudio Santo