Sara Peña-Gutiérrez

Ms. Sara Peña-Gutiérrez

Universitat Politècnica de Catalunya - Barcelona Tech, Dept. of Optical Engineering
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 January 2021 in Sensors
Verified
Journal Article
Open access
PDF file
LRLaura Rey-Barroso
Laura Rey-Barroso
Sara Peña-GutiérrezSara Peña-Gutiérrez
Sara Peña-Gutiérrez
CYCarlos Yáñez
Carlos Yáñez
FBFrancisco Burgos
Francisco Burgos
MVMeritxell Vilaseca
Meritxell Vilaseca
Santiago RoyoSantiago Royo
Santiago Royo
The worldwide incidence of skin cancer has risen rapidly in the last decades, becoming one in three cancers nowadays. Currently, a person has a 4% chance of developing melanoma, the most aggressive form of skin cancer, which causes the greatest number of deaths. In the context of increasing incidence and mortality, skin cancer bears a heavy health and economic burden. Nevertheless, the 5-year survival rate for people with skin cancer significantly improves if the disease is detected and treated early. Accordingly, large research efforts have been devoted to achieve early detection and better understanding of the disease, with the aim of reversing the progressive trend of rising incidence and mortality, especially regarding melanoma. This paper reviews a variety of the optical modalities that have been used in the last years in order to improve non-invasive diagnosis of skin cancer, including confocal microscopy, multispectral imaging, three-dimensional topography, optical coherence tomography, polarimetry, self-mixing interferometry, and machine learning algorithms. The basics of each of these technologies together with the most relevant achievements obtained are described, as well as some of the obstacles still to be resolved and milestones to be met.

27 October 2022 in Optics Express
Verified
Journal Article
Closed access
MBMaria Ballesta-Garcia
Maria Ballesta-Garcia
Sara Peña-GutiérrezSara Peña-Gutiérrez
Sara Peña-Gutiérrez
ARAna Rodríguez-Aramendía
Ana Rodríguez-Aramendía
PGPablo García-Gómez
Pablo García-Gómez
NRNoel Rodrigo
Noel Rodrigo
SRSantiago Royo
Santiago Royo
This paper focuses on exploring ways to improve the performance of LiDAR imagers through fog. One of the known weaknesses of LiDAR technology is the lack of tolerance to adverse environmental conditions, such as the presence of fog, which hampers the future development of LiDAR in several markets. Within this paper, a LiDAR unit is designed and constructed to be able to apply temporal and polarimetric discrimination for detecting the number of signal photons received with detailed control of its temporal and spatial distribution under co-polarized and cross-polarized configurations. The system is evaluated using different experiments in a macro-scale fog chamber under controlled fog conditions. Using the complete digitization of the acquired signals, we analyze the natural light media response, to see that due to its characteristics it could be directly filtered out. Moreover, we confirm that there exists a polarization memory effect, which, by using a polarimetric cross-configuration detector, allows improvement of object detection in point clouds. These results are useful for applications related to computer vision, in fields like autonomous vehicles or outdoor surveillance where many variable types of environmental conditions may be present.

5 January 2022 in Optics Letters
Verified
Journal Article
Closed access
Sara Peña-GutiérrezSara Peña-Gutiérrez
Sara Peña-Gutiérrez
MBMaria Ballesta-Garcia
Maria Ballesta-Garcia
PGPablo García-Gómez
Pablo García-Gómez
SRSantiago Royo
Santiago Royo
The polarization behavior of light transmitted through scattering media is studied quantitatively. A division of focal plane (DOFP) imaging polarimeter modified with a wideband quarter-wave plate (QWP) is used to evaluate the linear and circular depolarization signals. This system allows the measurement of the linear and circular co-polarization and cross-polarization channels simultaneously. The experiments are carried out at CEREMA’s 30 m fog chamber under controlled fog density conditions. The polarization memory effect with circularly polarized light is demonstrated to be superior in forward transmission compared to the same phenomena with linearly polarized light when imaging inside a scattering medium. This paves the way for its use in imaging through scattering media for hazard detection in different applications.

19 January 2023 in Optics Express
Verified
Journal Article
Closed access
Sara Peña-GutiérrezSara Peña-Gutiérrez
Sara Peña-Gutiérrez
SRSantiago Royo
Santiago Royo
This article intends to provide all the experimental insights and analyze the best polarimetric calibration method for a division of aperture polarimetric imager considering the different implications it has on the experimental set-up and its performance. Polarimetric cameras require careful calibration for the correct measurement of polarization information. The calibration methods are introduced, intermediate results are presented, and the ability of the set-up to estimate Stokes vectors and Mueller matrices of the samples in passive and active imaging modes is evaluated. Polarization information recovery achieves accuracy errors below the 10% for all polarization modes when the Data Reduction Matrix or the Eigenvalue Calibration Method are used. Such performance, however, degrades significantly when using the Polarizer Calibration Method. To the best of our knowledge, this is the first time such a detailed comparison of calibration methods is presented in the literature, and it is also the first time the Polarizer Calibration Method is applied to a division of aperture polarimeter.

24 June 2021 in Atmosphere
Verified
Journal Article
Open access
PDF file
MBMaria Ballesta-Garcia
Maria Ballesta-Garcia
Sara Peña-GutiérrezSara Peña-Gutiérrez
Sara Peña-Gutiérrez
AVAina Val-Martí
Aina Val-Martí
Santiago RoyoSantiago Royo
Santiago Royo
We compare conventional intensity imaging against different modes of polarimetric imaging by evaluating the image contrast of images taken in a controlled foggy environment. A small-scale fog chamber has been designed and constructed to create the necessary controlled foggy environment. A division-of-focal-plane camera of linear polarization and a linearly polarized light source has been used for performing the experiments with polarized light. In order to evaluate the image contrast of the different imaging modes, the Michelson contrast of samples of different materials relative to their background has been calculated. The higher the image contrast, the easier it is to detect and segment the targets of interest that are surrounded by fog. It has been quantitatively demonstrated that polarimetric images present an improvement in contrast compared to conventional intensity images in the situations studied.

1 November 2023 in Sensors
Verified
Journal Article
Open access
PDF file
MBMaria Ballesta-Garcia
Maria Ballesta-Garcia
Sara Peña-GutiérrezSara Peña-Gutiérrez
Sara Peña-Gutiérrez
PGPablo García-Gómez
Pablo García-Gómez
Santiago RoyoSantiago Royo
Santiago Royo
This paper focuses on the experimental characterization of the polarization behavior of light backscattered through fog. A polarimetric orthogonal state contrast imager and an active, purely polarized white illuminator system are used to evaluate both linear and circular polarization signals. The experiments are carried out in a macro-scale fog chamber under controlled artificial fog conditions. We explore the effect of backscattering in each imaging channel, and the persistence of both polarization signals as a function of meteorological visibility. We confirm the presence of the polarization memory effect with circularly polarized light, and, as a consequence, the maintenance of helicity in backscattering. Moreover, the circular cross-polarized channel is found to be the imaging channel less affected by fog backscattering. These results are useful and should be taken into account when considering active polarimetric imaging techniques for outdoor applications under foggy conditions.