Meritxell Vilaseca

Dr. Meritxell Vilaseca

Universitat Politècnica de Catalunya - Barcelona Tech
orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 December 2010 in Current Eye Research
Verified
Journal Article
Closed access
GCGenis Cardona
Genis Cardona
CGCarles García
Carles García
CSCarme Serés
Carme Serés
MVMeritxell Vilaseca
Meritxell Vilaseca
JGJoan Gispets
Joan Gispets
The present study aimed at investigating the influence of the level of dynamism of two different visual display terminal tasks on spontaneous eyeblink rate, blink amplitude, and tear film integrity. A total of 25 healthy, young volunteers participated in the study. Blink rate and blink amplitude were recorded in silent primary gaze conditions and while subjects were playing two computer games of similar cognitive demands but different rate of visual information presentation. For each experimental condition, tear volume was evaluated by measuring meniscus height and with the red phenol thread test. Fluorescein and non-invasive break-up time tests, as well as the observation of interference patterns and the estimation of the dry area extension, were employed to assess tear stability. Statistically significant differences were revealed in blink rate (F = 595.85, p < 0.001) and blink amplitude (χ(2) = 34.00, p < 0.001), with blink rate during fast- and slow-paced game play decreasing to almost 1/3 and 1/2 of baseline levels, respectively, and with a larger percentage of incomplete blinks during dynamic tasks. Fluorescein and non-invasive break-up time tests and dry area extension were able to differentiate between experimental conditions in general (F = 408.42, p < 0.001; F = 163.49, p < 0.001; χ(2) = 20.74, p < 0.001), as well as between fast- and slow-paced games, thus suggesting that tear quality was more affected than tear volume. Blink rate, blink amplitude, and tear film stability were compromised during the most dynamic visual display terminal task, suggesting a negative influence of not only the cognitive aspects of the task, but also of the rate at which new visual information is presented. Frequent breaks and blinking awareness training are recommended for visual display terminal users requiring prolonged periods of visually demanding dynamic computer play or work.

2 January 2021 in Sensors
Verified
Journal Article
Open access
PDF file
LRLaura Rey-Barroso
Laura Rey-Barroso
Sara Peña-GutiérrezSara Peña-Gutiérrez
Sara Peña-Gutiérrez
CYCarlos Yáñez
Carlos Yáñez
FBFrancisco Burgos
Francisco Burgos
MVMeritxell Vilaseca
Meritxell Vilaseca
Santiago RoyoSantiago Royo
Santiago Royo
The worldwide incidence of skin cancer has risen rapidly in the last decades, becoming one in three cancers nowadays. Currently, a person has a 4% chance of developing melanoma, the most aggressive form of skin cancer, which causes the greatest number of deaths. In the context of increasing incidence and mortality, skin cancer bears a heavy health and economic burden. Nevertheless, the 5-year survival rate for people with skin cancer significantly improves if the disease is detected and treated early. Accordingly, large research efforts have been devoted to achieve early detection and better understanding of the disease, with the aim of reversing the progressive trend of rising incidence and mortality, especially regarding melanoma. This paper reviews a variety of the optical modalities that have been used in the last years in order to improve non-invasive diagnosis of skin cancer, including confocal microscopy, multispectral imaging, three-dimensional topography, optical coherence tomography, polarimetry, self-mixing interferometry, and machine learning algorithms. The basics of each of these technologies together with the most relevant achievements obtained are described, as well as some of the obstacles still to be resolved and milestones to be met.

1 August 2011 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
ABAntonio Benito
Antonio Benito
GPGuillermo M. Pérez
Guillermo M. Pérez
SMSandra Mirabet
Sandra Mirabet
MVMeritxell Vilaseca
Meritxell Vilaseca
JPJaume Pujol
Jaume Pujol
PAPablo Artal
Pablo Artal
To evaluate and compare the tear-film dynamics in normal eyes and in eyes with mild dry-eye symptoms using a new noninvasive optical method based on a double-pass instrument. Hospital Universitario Virgen de la Arrixaca, Murcia, Spain. Evaluation of diagnostic test or technology. Dynamic recording of double-pass retinal images during unforced tear-film breakup was performed in eyes with mild dry-eye symptoms (study group) and in an asymptomatic control group. Series of consecutive retinal images were recorded every 0.5 seconds while the patient avoided blinking. Measurements were performed under low-light conditions to naturally increase pupil diameter and maximize the method's sensitivity. Additional clinical tests were performed for comparison and included tear breakup time (TBUT), Schirmer I tests, and a normalized questionnaire (McMonnies). From the retinal images, a quality metric, the intensity distribution index, was calculated. An objective TBUT value was estimated in each eye when the intensity distribution index surpassed a defined threshold value compared with the initial baseline. The study group comprised 20 eyes and the control group, 18 eyes. Symptomatic dry eyes had a typical exponential increase in the intensity distribution index with time. The objective TBUT values in the study group were comparable to the clinical TBUT estimates. The new objective optical method to evaluate the quality and stability of the tear film was sensitive in detecting mild symptoms of dry eye and differentiating from normal cases. The procedure may allow early detection and follow-up of patients' tear film-related complaints.

17 November 2010 in Clinical and Experimental Optometry
Verified
Journal Article
Open access
PDF file
JMJoan A Martínez‐Roda
Joan A Martínez‐Roda
MVMeritxell Vilaseca
Meritxell Vilaseca
JOJuan C Ondategui
Juan C Ondategui
AGAnna Giner
Anna Giner
FBFrancisco Burgos
Francisco Burgos
JPJaume Pujol
Jaume Pujol
Background: We objectively assessed the optical quality and intraocular scattering by means of parameters provided by a clinical double‐pass system in healthy young subjects and thereby we obtained new reference data for clinical diagnosis. We calculated normal values of neural contrast sensitivity function (nCSF) from the measured modulation transfer function (MTF) and the contrast sensitivity function (CSF). Methods: Eligible subjects were healthy adults aged from 18 to 30 years with a logMAR visual acuity (VA) of 0.0 or better and normal values of CSF. Optical quality measurements for a 4.0 mm pupil were performed using the Optical Quality Analysis System (OQAS) based on the double‐pass technique. The following parameters were analysed: the modulation transfer function cutoff frequency (MTFcutoff), the Strehl2D ratio, the OQAS values (OV) at 100, 20 and nine per cent contrasts and the objective scatter index (OSI). Results: A total of 178 volunteers responded to the call, of whom 181 eyes were finally part of the study taking into account the criteria for inclusion. The values for the optical quality parameters were: 44.54 ± 7.14 cpd (MTFcutoff), 0.27 ± 0.06 (Strehl2D ratio), 1.48 ± 0.24 (OV100%), 1.58 ± 0.32 (OV20%), 1.64 ± 0.39 (OV9%), and 0.38 ± 0.19 (OSI). The nCSF calculated was 1.76 ± 0.21 (3 cpd), 2.13 ± 0.23 (6 cpd), 2.01 ± 0.28 (12 cpd) and 1.86 ± 0.33 (18 cpd). Conclusion: The normal values provided can be a useful tool for discriminating healthy eyes from early abnormal ones in which the optical quality or sensory function is impaired.

1 September 2010 in Optometry and Vision Science
Verified
Journal Article
Closed access
MVMeritxell Vilaseca
Meritxell Vilaseca
EPElvira Peris
Elvira Peris
JPJaume Pujol
Jaume Pujol
RBRosa Borras
Rosa Borras
MAMontserrat Arjona
Montserrat Arjona

11 July 2012 in British Journal of Ophthalmology
Verified
Journal Article
Open access
PDF file
MVMeritxell Vilaseca
Meritxell Vilaseca
MRMaria José Romero
Maria José Romero
MAMontserrat Arjona
Montserrat Arjona
SLSergio Oscar Luque
Sergio Oscar Luque
JOJuan Carlos Ondategui
Juan Carlos Ondategui
JPJaume Pujol
Jaume Pujol
Purpose To evaluate objectively intraocular scattering in eyes with nuclear, cortical and posterior subcapsular cataracts by means of an objective scatter index (OSI) obtained from double-pass images. To compare the results with those obtained using clinical conventional procedures. Methods In this prospective, observational, cross-sectional, non-consecutive case series study, 188 eyes with cataracts of 136 patients were analysed (123 eyes had nuclear, 41 eyes had cortical and 24 eyes had posterior subcapsular cataracts). The control group consisted of 117 eyes of 68 healthy patients. Patient examination included subjective refraction, best spectacle-corrected visual acuity (BSCVA), cataract grade using the lens opacities classification system III (LOCS III) and OSI. Results We found a decrease in the BSCVA and an increase in the OSI with increasing cataract grade. Statistically significant differences were observed when the OSI of eyes without cataracts and those with different LOCS III were compared. The comparison between the OSI and LOCS III reported good percentages of agreement regarding the number of eyes classified in equivalent levels: 72.4% (nuclear cataracts), 86.6% (cortical cataracts) and 84.3% (posterior subcapsular cataracts). A non-linear regression model was applied between OSI and BSCVA, which resulted in the following multiple correlation coefficients: r=0.878 (nuclear), r=0.843 (cortical) and r=0.844 (posterior subcapsular). Conclusions The results of the study showed that OSI is a useful parameter for evaluating large amounts of intraocular scattering that can be used, in combination with other conventional procedures, as a valuable tool in clinical practice to grade cataracts objectively.