Sattaya Manokeaw

Mr. Sattaya Manokeaw

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 September 2025 in Technologies
Verified
Journal Article
Open access
PDF file
SMSattaya Manokeaw
Sattaya Manokeaw
PKPattaraporn Khuwuthyakorn
Pattaraporn Khuwuthyakorn
YCYing-Chieh Chan
Ying-Chieh Chan
NTNaruephorn Tengtrairat
Naruephorn Tengtrairat
MJManissaward Jintapitak
Manissaward Jintapitak
Damrongsak RinchumphuDamrongsak Rinchumphu
Damrongsak Rinchumphu
This study presents the development and deployment of a modular digital twin system designed to enhance sustainable facility management within a smart campus context. The system was implemented at the Faculty of Engineering, Chiang Mai University, and integrates 3D spatial modeling, real-time environmental and energy sensor data, and multiscale dashboard visualization. Grounded in stakeholder-driven requirements, the platform emphasizes energy management, which is the top priority among campus administrators and technicians. The development process followed a four-phase methodology: (1) stakeholder consultation and requirement analysis; (2) physical data acquisition and 3D model generation; (3) sensor deployment using IoT technologies with NB-IoT and LoRaWAN protocols; and (4) real-time data integration via Firebase and standardized APIs. A suite of dashboards was developed to support interactive monitoring across faculty, building, floor, and room levels. System testing with campus users demonstrated high usability, intuitive spatial navigation, and actionable insights for energy consumption analysis. Feedback indicated strong interest in features supporting data export and predictive analytics. The platform’s modular and hardware-agnostic architecture enables future extensions, including occupancy tracking, water monitoring, and automated control systems. Overall, the digital twin system offers a replicable and scalable model for data-driven facility management aligned with sustainability goals. Its real-time, multiscale capabilities contribute to operational transparency, resource optimization, and climate-responsive campus governance, setting the foundation for broader applications in smart cities and built environment innovation.

28 October 2025 in Journal of Architectural/Planning Research and Studies (JARS)
Verified
Journal Article
Open access
PDF file
Damrongsak RinchumphuDamrongsak Rinchumphu
Damrongsak Rinchumphu
CBChinnapat Buachart
Chinnapat Buachart
WTWarut Timprae
Warut Timprae
SMSattaya Manokeaw
Sattaya Manokeaw
PKPattaraporn Khuwuthyakorn
Pattaraporn Khuwuthyakorn
YCYing-Chieh Chan
Ying-Chieh Chan
Indoor air quality, particularly carbon dioxide (CO₂) levels, is critical to occupants’ health and comfort. This study developed predictive models for indoor CO₂ concentrations based on environmental variables, including light, temperature, humidity, and the presence of plants. Data collected from sensors within a controlled indoor environment were used to train predictive models using various techniques, including artificial neural networks (ANN), k-Nearest Neighbors (k-NN), Random Forest, and generalized linear models. Among standalone models, the ANN with a 70:30 train-test split yielded the best performance, achieving a root mean square error (RMSE) of 10.960, mean absolute error (MAE) of 7.300, and a coefficient of determination (R²) of 0.640. The study further explored ensemble methods by combining ANN, k-NN, and generalized linear models through soft voting. The optimal ensemble configuration—ANN and k-NN with a 90:10 split ratio—achieved an RMSE of 11.437, MAE of 8.153, and R² of 0.650, outperforming the standalone models. In addition, the results demonstrated that the presence of plants within a room significantly reduced CO₂ levels under specific conditions (20-30°C and 200 lux), highlighting plants' potential to improve indoor air quality. This research suggests that ensemble models offer a viable solution for accurate indoor CO₂ prediction, with practical applications in indoor environmental management, especially when coupled with biophilic design elements such as indoor plants.

31 January 2025 in Nakhara : Journal of Environmental Design and Planning
Verified
Journal Article
Open access
PDF file
DRDamrongsak Rinchumphu
Damrongsak Rinchumphu
SMSattaya Manokeaw
Sattaya Manokeaw
TAThidarat Kridakorn Na Ayutthaya
Thidarat Kridakorn Na Ayutthaya
Manat SrivanitManat Srivanit
Manat Srivanit
EWEkbordin Winijkul
Ekbordin Winijkul
WAWitsarut Achariyaviriya
Witsarut Achariyaviriya
Air quality assessment in particulate matter with a size of less than 2.5 microns (PM2.5) is essential because it affects urban residential health. Hence, this research studied the analysis of PM2.5 value from antique Mon handmade stove house usage in Chiang Mai, using the AERMOD air quality dispersion model. The data for the modeling was collected from a survey regarding the amounts of production and fuel, and the location of the brick kilns used to calculate the amount of air pollution emissions. The summarized values were the emission factor, the climate data as the surface meteorological data, the upper-air meteorological data obtained from the National Oceanic and Atmospheric Administration, and national geographic data. The Albedo and Bowen ratios and the surface roughness values were identified using satellite data and then presented in a map of the dust intensity distribution. The results found that the highest value of PM2.5 concentration at the smoke point was 209.19 μg/m3, while the average values were 48.21 μg/m3. The PM2.5 concentration at the stack pointer was higher than the standard scores of Thai and World Health Organization (WHO) general atmospheric air quality standards. However emissions varied, and average PM2.5 concentrations exceeded WHO standards and, in the case of full operation, exceeded Thai standards, posing health risks.