The current climatic scenario requires the use of innovative solutions to increase the production of electricity from renewable energy sources. Multilevel Power Inverters are a promising solution to improve the penetration of renewable energy sources into the electrical grid. Moreover, the performance of MPIs is a function of the modulation strategy employed and of its features (modulation index and switching frequency). This paper presents an extended and experimental analysis of three-phase five-level Cascaded H-Bridges Multilevel Inverter performance in terms of efficiency and harmonic content considering several MC PWM modulation strategies. In detail, the CHBMI performance is analyzed by varying the modulation index and the switching frequency. For control purposes, the NI System On Module sbRIO-9651 control board, a dedicated FPGA-based control board for power electronics and drive applications programmable in the LabVIEW environment, is used. The paper describes the modulation strategies implementation, the test bench set-up, and the experimental investigations carried out. The results obtained in terms of Total Harmonic Distorsion (THD) and efficiency are analyzed, compared, and discussed.
5 February 2024 in IEEE Journal of Emerging and Selected Topics in Power Electronics
In this work, a novel multi-objective voltage-vector-based finite control set model predictive control for a permanent magnet synchronous machine drive fed by a three-phase five-level cascaded H-bridge multilevel inverter is proposed. This algorithm aims to overcome the main issues relative to model predictive control implementation detected in the scientific literature for electric drives fed by cascaded H-bridge multilevel inverters. In detail, the goals are the minimization of computational cost by reducing the number of required predictions, the minimization of the switching devices state transitions, i.e. the switching losses minimization, and the common mode voltage reduction. These goals are fulfilled through an offline optimization process, thus, no additional terms and weighting factors to be tuned are required for the cost function. Experimental validations are presented to prove the effectiveness of the proposed approach. In detail, an accurate electric drive performance comparison, both in steady state and dynamic working conditions, is carried out when the proposed voltage-vector-based model predictive control and the cell-by-cell-based model predictive control are adopted. As comparison tools, current and voltage total harmonic distortion, apparent switching frequency, common mode voltage amplitude, and torque ripple are adopted.
24 July 2024 in IEEE Open Journal of Power Electronics
This paper proposes a general analytical formulation for LCL filter design for grid-connected PWM-driven cascaded H-bridge inverters. The novelty of this work deals with providing some easy-of-use analytical expressions that allow for properly sizing the filter inductances and capacitance values considering the number of voltage levels, the DC-link voltage, the adopted multicarrier pulse width modulation strategy, and the switching frequency. Although multilevel inverters performance strongly depends on the adopted modulation strategy and switching frequency, a general mathematical formulation that allows for properly sizing the LCL filter by considering such parameters simultaneously is currently missing. The proposed approach is generalized for the most adopted multicarrier pulse width modulation strategies. To validate the proposed approach, an extended investigation analysis is performed by hardware-in-the-loop real-time tests. According to international standards EN50160 and IEEE Std 1547–2018, the voltage total harmonic distortion and current total rated distortion are adopted to evaluate the LCL filter performance. Tests are carried out in several working conditions, defined in terms of provided apparent power and power factor values. Finally, the proposed analytical formulation is adopted to formulate an optimized LCL filter design algorithm that allows for matching the standard requirements without oversizing the filter parameters.
29 May 2025 in IEEE Open Journal of the Industrial Electronics Society
This work aims to highlight the inadequacy of international standards IEC 60034-2-3 and IEC 60034-30-2 for accurate efficiency, power losses, and efficiency class determination of AC motors fed by multilevel inverters driven with multicarrier PWM strategies. The main motivation of this work stems from the fact that international standards IEC 60034-2-3 and IEC 60034-30-2 prescribe the use of the two-level voltage source inverter for AC motor losses, efficiency, and efficiency classes determination, even for multilevel-inverter-fed AC motor. Therefore, this analysis aims to experimentally demonstrate IEC standards inadequacy, emphasizing the need to update them and provide a comprehensive framework for developing a power measurement procedure, specifically tailored to multilevel inverter-fed AC drives. More specifically, the goal is to support standardization bodies by simplifying their task and enabling IEC standards generalization to almost every multicarrier PWM-controlled multilevel inverter-fed AC drive. To this end, an accurate power loss analysis of an interior permanent magnet synchronous motor fed by a five-level cascaded H-bridge inverter, controlled with several multicarrier PWMs, is carried out. In detail, a precise power analysis in the frequency domain is performed to evaluate the impact of modulation strategies on motor power losses at different operating points in the speed-torque plane in terms of power losses, fundamental, and harmonic power losses. The motor power losses obtained with a five-level cascaded H-bridge multilevel inverter are compared to those obtained with a conventional two-level voltage source inverter, demonstrating that the application of IEC 60034-2-3 and IEC 60034-30-2 provide an underestimated motor energy efficiency class (IE-code).
8 July 2024 in IEEE Transactions on Power Electronics
In this work, a novel split-space-vector-based finite control set model predictive control (MPC) for an interior permanent magnet synchronous motor drive fed by a three-phase five-level cascaded H-bridge multilevel inverter is proposed. The key novelty of this work is related to the ability of the proposed algorithm to guarantee the inverter submodules (SMs) dc power balancing by introducing some switching constraints aimed to emulate the phase-shifted pulsewidth modulation switching pattern, which naturally guarantees the SMs dc power balancing. Then, the main contribution of this work is guaranteeing the SMs dc power balancing without resorting to an explicit modulation stage or to a devoted term into the cost function. Indeed, the former reduces the system dynamic, the latter imposes measuring the dc voltages and tuning the cost function weighting factors. Moreover, the adopted switching constraints and an offline optimization process allow for guaranteeing the minimum computational burden. The proposed control algorithm's effectiveness is proven by experimental tests both in steady-state and dynamic working conditions and by comparison with a very-low computational burden voltage-vector-based finite control set MPC.
12 January 2026 in IEEE Open Journal of Power Electronics
This paper presents a novel multi-objective finite-control-set model predictive control strategy for LCL-filtered grid-connected three-phase five-level cascaded H-bridge multilevel inverters operating at low-switching frequency. The key novelty lies in the proposed algorithm capability to ensure compliance with EN 50160 and IEEE Std 1547-2018 standards even under low-switching frequency conditions, without requiring a fixed switching frequency and symmetrical voltage waveform, typically guaranteed by a devoted modulation stage, and without oversizing the LCL filter. To achieve this goal, a multi-term cost function is designed to regulate inverter-side currents, capacitor voltages, and switching effort. For control validation, comparative analysis between the proposed strategy and the phase-shifted pulse width modulation-based voltage-oriented control is conducted at the same average switching frequency. Results show that only the proposed control strategy meets the grid standard requirements. Furthermore, the proposed FCS-MPC maintains standard compliance while further reducing the switching frequency, thus outperforming the voltage-oriented control. Finally, the proposed strategy exhibits intrinsic active damping capability and guarantees superior steady-state and dynamic performance compared to standard active damping strategies in the literature.