Shao-Fu Huang

Dr. Shao-Fu Huang


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

24 February 2016 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
SHShao-Fu Huang
Shao-Fu Huang
WCWan-Rung Chen
Wan-Rung Chen
Chunli LinChunli Lin
Chunli Lin
This study investigated the biomechanical interactions in endodontically treated tooth implant-supported prosthesis (TISP) with implant system variations under dynamic cyclic loads monitored using the acoustic emission (AE) technique. Macrostructure implants using a taper integrated screw-in (TIS; 2-piece implant) and a retaining-screw (RS; 3-piece implant) connected to an abutment were used for this investigation and their corresponding mechanical resistances in conformity with the ISO 14801 standard were evaluated. The endodontically treated TISP samples were constructed containing TIS and RS implants splinted to the second premolar with fatigue tests performed by applying occlusal force onto the premolar simulating the bending moment effect. The numbers of accumulated AE signals in the fatigue tests and failure modes for the sample were recorded to evaluate the mechanical resistance. The maximum load in the static test for RS (3-piece) implant (797N) was significantly higher than that for the TIS (2-piece) implant (559N). Large deformations were found at abutment screws in both RS and TIS implants. Although the numbers of accumulated AE signals for the TIS implant (72511) were higher than those for the RS implant (437), statistical non-significant differences were found between TIS and RS implants. No obvious damage was noted in endodontically treated TISP samples using RS implants but two of the corresponding TIS implants fractured in the abutment screws. Splints with RS (3-piece) implant prosthesis produce better mechanical responses than the TIS (2-piece) implant when connected to an endodontically treated tooth restored with a post core and crown.


3 August 2026 in Bioengineering
Verified
Journal Article
Open access
PDF file
CCChih-Chang Chang
Chih-Chang Chang
SHShao-Fu Huang
Shao-Fu Huang
PHPin-Cang Huang
Pin-Cang Huang
Chunli LinChunli Lin
Chunli Lin
Background: Allograft bone remains an attractive option for anterior cervical corpectomy and fusion (ACCF), but its use can be limited by variable graft geometry, insufficient endplate contact, and operator-dependent trimming. This study aimed to develop a titanium end-disc-assisted allograft construct with a standardized cutting and assembly system and to preliminarily evaluate its static mechanical integrity under axial compression, compression-shear, and torsional loading. Methods: The construct consisted of a controlled-length bone graft, two Ti6Al4V end-discs, and four countersunk fixation screws, forming a graft–disc construct with a maximum total height not exceeding 40 mm. The end-discs incorporated angled screw holes, bone-graft filling spaces, and enlarged contact surfaces. A modular preparation system was designed for graft clamping, length definition, guided cutting, alignment, pre-drilling, and screw fixation. Porcine rib specimens were used as an allograft substitute. Native bone and assembled constructs were tested under static compression, compression-shear, and torsion. Results: The system produced standardized constructs. Except for axial compressive stiffness, the assembled constructs showed numerically higher compressive yield force, shear stiffness, shear yield force, torsional stiffness, and yield torque than native bone; however, these findings were interpreted descriptively because of the limited sample size. Failure occurred mainly within the bone, with no obvious failure at the bone–titanium interface, titanium end-discs, or fixation screws. Conclusions: The proposed system enabled standardized graft preparation and construct assembly. Further fatigue, subsidence, and clinically relevant cervical spine model testing are required.

Verified
Journal Article
Open access
PDF file
CTChia Hung Tsai
Chia Hung Tsai
SHShao-Fu Huang
Shao-Fu Huang
RLRong-Chen Lin
Rong-Chen Lin
PLPao-Wei Lee
Pao-Wei Lee
CLCheng-Ying Lee
Cheng-Ying Lee
Chunli LinChunli Lin
Chunli Lin
Suture anchors are widely used for tendon and ligament repair, but their fixation strength is compromised in osteoporotic bone and limited bone volume such as the coracoid process. Existing designs are prone to penetration and insufficient cortical engagement under such conditions. In this study, we developed a novel short expandable-wing (SEW) suture anchor (Ti6Al4V) designed to enhance pull-out resistance through a deployable wing mechanism that locks directly against the cortical bone. Finite element analysis based on CT-derived bone material properties demonstrated reduced intra-bone displacement and improved load transfer with the SEW compared to conventional anchors. Mechanical testing using matched artificial bone surrogates (N = 3 per group) demonstrated significantly higher static pull-out strength in both normal (581 N) and osteoporotic bone (377 N) relative to controls (p < 0.05). Although the sample size was limited, results were consistent and statistically significant. After cyclic loading, SEW anchor fixation strength increased by 25–56%. In a 3D-printed anatomical coracoclavicular ligament reconstruction model, the SEW anchor provided nearly double the fixation strength of the hook plate, underscoring its superior stability under high-demand clinical conditions. This straightforward implantation protocol—requiring only a 5 mm drill hole without tapping, followed by direct insertion and knob-driven wing deployment—facilitates seamless integration into existing surgical workflows. Overall, the SEW anchor addresses key limitations of existing anchor designs in small bone volume and osteoporotic environments, demonstrating strong potential for clinical translation.