Gas‐viscous liquid bubbly and slug flow are very common in petroleum, chemical, bioengineering, polymer, and food processing. However, there is a major knowledge gap in two‐phase flow research in the design of gas injectors/distributers in very high viscosity oil systems. The present study investigates the effect of gas injection methods in columns containing very high viscosity oils (i.e., realistic liquids), and more specifically using 360 Pa · s viscosity oil in a 240‐mm diameter column. The effects that the radial positioning, number of gas nozzles, and their distance from each other have on the structure of the flow in viscous liquids are presented in detail. Electrical capacitance tomography (ECT) is used to extract experimental data. Void fraction, bubble velocity, frequency, liquid film thickness, and bubble length were measured and analyzed at different radial gas injection positions. It has been observed that bubble length increases significantly by 0.3 m when the injection nozzle is located next to the wall of the pipe. Bubble velocity and length also increase by 0.217 m/s and 3.6 m, respectively, with increasing gas flowrate when multiple injection points are used. Increasing the distance between the gas injection points increased bubbles' length by 1.2 m. Bubbles' velocity and frequency (at higher gas flow rate) were also increased.
Many of the film thickness measurements that have been reported in the literature tend to focus on small pipe diameters, which may not be practical for a variety of industrial applications. Additionally, single-point measurements are unable to provide the necessary film thickness data around the circumference of the pipe as well as in the axial direction. This paper aims to experimentally study the behaviour of wavy liquid films, including wave frequency, wave velocity, wave width, and wave spacing. A Multi-Pin Film Sensor (MPFS) was used to extract the thickness of a free-falling liquid film in axial, circumferential, and temporal coordinates. The range of liquid Reynolds number ReL used was 618–1670. It was found that the power spectral density of the disturbance waves showed a pronounced peak at the modal frequency of 6–8 Hz. The number of disturbance waves was found to be almost independent of ReL. The axial interfacial wave seemed to travel at a constant velocity while the mean velocity in circumferential direction was negligible. The mean width of the disturbance waves was approximately 17.7% of the pipe diameter.
17 April 2022 in International Journal of Multiphase Flow