Recently, the IMO (International Maritime Organization) has reviewed technical issues considering the second generation intact stability criteria in the design stage of ships. In this paper, the evaluation procedure for Lv1 (Level 1) and Lv2 (Level 2) was introduced by focusing on the excessive acceleration mode. Based on real ship data, the calculation process has been explained in detail to make it easy to understand. When the Lv1 criteria considering simple hydrostatic calculations are not satisfied, the computational results of the Lv2 criteria based on mathematical modeling and the hydrodynamics are presented. The relatively low ship roll periods and large changes in the hull shape in the vertical direction make the ships potentially vulnerable to excessive acceleration phenomena. Therefore, the minimum value of height KG that satisfies the stability criteria evaluation in consideration of loading conditions for actually navigating of the ship in the sea should be estimated and operated. In particular, roll damping coefficients using the Ikeda’s method, which are essential for Lv2 vulnerability calculation, were obtained and verified by comparing them with other ship results.
With increasingly stringent emissions legislation, such as that stipulated by the International Maritime Organization, for nitrogen oxide emission reduction in marine diesel engines, the imperative of curtailing nitrogen oxide emissions from marine diesel engines is intensifying. Consequently, the significance of aftertreatment technologies, including diesel particulate filters (DPFs) and selective catalytic reduction (SCR), is poised to grow substantially. In particular, a redesign is required to reduce the size of DPF and SCR systems for application in small ships. In this study, we varied the shape of the filters in DPF and SCR systems, aiming to achieve a distinct flow pattern and enable overall miniaturization. The performance metrics, including the nitric oxide (NO) reduction rate, NH3 slip rate, and pressure drop, of the redesigned models were compared with those of the conventional model. Computational fluid dynamics simulations were used to compare the performance of the redesigned model with that of the conventional model in terms of NO reduction and pressure drop. The redesigned system achieved a NO reduction rate of 6.9% below that of the conventional system, offering additional noteworthy benefits such as a 50% reduction in both pressure and overall length.
28 January 2025 in Case Studies in Thermal Engineering