28 July 2022 in Journal of Electronics, Electromedical Engineering, and Medical Informatics
Verified
Journal Article
Open access
PDF file
ASArrum Sekarwati
Arrum Sekarwati
SSSyaifudin Syaifudin
Syaifudin Syaifudin
THTorib Hamzah
Torib Hamzah
SMShubhrojit Misra
Shubhrojit Misra
Infant incubators are equipment to maintain a stable body temperature for premature babies. Premature babies need room conditioning that is close to conditions in the womb. Room conditioning is carried out in a baby incubator by providing a stable temperature, relative humidity, and measured air flow. This parameter must be controlled so as not to exceed the threshold that will harm the baby. Periodic calibration should be applied to the infant incubator to monitor its function. To ensure the availability of baby incubators according to service standards, it is necessary to conduct test (calibrate) using an incubator analyzer. The purpose of this study is to conduct further research on the incubator analyzer that focuses on discussing the accuracy of noise and airflow sensors with the gold standard. In this study, an experiment was carried out for the sensitivity level of several sensors that had been treated by giving treatment to sensors to choose sensors with good sensitivity to be assembled into one in the incubator analyzer module. The noise sensors (KY-037 and Analog Sound Sensor V2.2) were further compared with the values ​​on the sound level meter and the airflow sensor (D6F-V03A1) was compared with the anemometer. Sensors whose values ​​are close to the comparison values ​​were selected to be integrated into the incubator analyzer module. The incubator analyzer module used Arduino Mega2560 as a data processor and was equipped with an SD Card for the data storage. The built incubator analyzer module was also compared to the Fluke INCU II gold standard for data analysis. The results showed that the Analog Sound Sensor V2.2 had the highest error value (-4.6%) at 32°C and the D6F-V03A1 had the ability to measure sensitivity, where the results were more accurate than INCU II. Based on the error value of the noise sensor, the V2.2 sensor can be applied to measure noise in the baby incubator and the D6F-V03A1 airflow sensor produced an accuracy of up to 3 digits behind the comma which is more accurate than the standard module. The results of the INCU analyzer from this study can be used to calibrate the baby incubator, so that the certainty of the feasibility of the baby incubator is guaranteed. This research can be used as a reference for other researchers who will develop research on incubator analyzers in the future.

18 September 2022 in Measurement: Sensors
Verified
Journal Article
Open access
SSS. Selvakanmani
S. Selvakanmani
ABAshreetha B
Ashreetha B
GDG. Naga Rama Devi
G. Naga Rama Devi
SMShubhrojit Misra
Shubhrojit Misra
JRJayavadivel R
Jayavadivel R
SPSuresh Babu Perli
Suresh Babu Perli

7 June 2022 in Jurnal Teknokes
Verified
Journal Article
Open access
PDF file
AMAnita Miftahul Maghfiroh
Anita Miftahul Maghfiroh
FAFarid Amrinsani
Farid Amrinsani
RFRafi Maulana Firmansyah
Rafi Maulana Firmansyah
SMShubhrojit Misra
Shubhrojit Misra
Babies need temperatures that match the temperature of the mother's womb, which is between 35°C – 37°C. The latest research on infant warmer device used fuzzy method as a system for controlling temperature in infant warmers. The problem raised in the previous research is that the temperature was not evenly distributed throughout the bed at each predetermined temperature setting. When it reached the setting temperature, the warmer continued to turn on so that the bed got hotter. Therefore, the purpose of the current research is to make an infant warmer device equipped with digital scales with a temperature setting of 350C- 370C using PID control to stabilize the temperature and ensure that the heat is evenly distributed on the bed. In addition, skin temperature is also added, allowing the nurses know at which level of patient's body temperature is when observations should be made. The infant warmer in this module used an arduino microcontroller which is displayed in 7 segments, the skin sensor used is the DS18B20 temperature sensor to read the skin temperature, while the infant warmer temperature sensor used is LM35 as a PID control system. The results of the current research in making the device module were compared with the measurement results of the comparator. It was revealed that current research has obtained smallest error of 0% in temperature setting of 350C. For the comparison with the incu analyzer, the smallest error was obtained at the temperature setting of 370C with an error value of 0% on the T5 measurement. Meanwhile, the difference in skin temperature against the thermometer is 0.10C. The results showed that the temperature distributed on the module had different error values. Hence, this research can be implemented on the PID control of infant warmer system to improve the performance of infant temperature stability.

24 November 2022 in Indonesian Journal of electronics, electromedical engineering, and medical informatics
Verified
Journal Article
Open access
PDF file
CPCandra Prastyadi
Candra Prastyadi
BIBambang Guruh Irianto
Bambang Guruh Irianto
HAHer Gumiwang Ariswati
Her Gumiwang Ariswati
DTDyah Titisari
Dyah Titisari
SNSteyve Nyatte
Steyve Nyatte
SMShubhrojit Misra
Shubhrojit Misra
A laboratory incubator is a tool used to incubate or incubate a breed. Incubators provide optimum temperature conditions for microorganisms to grow. The incubator has a temperature regulator so that the temperature can be adjusted according to the breed to be incarnated. Incubators utilize hot-dry like ovens. The purpose of this study is to conduct testing and analyze the accuracy of thermocouple sensors with incubator media in laboratory incubator calibrator tools. The contribution of the research is to know the level of accuracy of the sustainable sensor for sensing the temperature in the lab incubator. The main Design consists of 8 MAX 6675 Standards, 8 Thermocouple type K, Arduino Mega, and SD Card Standards. The temperature not in the incubator device is measured by a Type K thermocouple sensor. Thermocouple sensor numbers 8 channels that measure the temperature at each incubator camber point. The temperature will be stored on the SD card to analyze the data and the data can be processed into the form of a graphic. Benchmarking is done using a data logger temperature tool. This is done to make the Design results are under the standards of the Standard. After comparing with the Standard get the largest error value is 3.98%, at channel T6 temperature 35 °C with ordinary incubator media and the smallest error in ordinary incubator media point T6 temperature 37 ° C which is 0.06 % and in fan incubator temperature 35 C has the largest error which is 2.98 % and the smallest error 0.86%. The conclusion of this study is that the design can work well in measuring the temperature of the incubator, as well as the system for storing readings using the SD card Design and sending data using the internet network can work well.

8 December 2022 in Jurnal Teknokes
Verified
Journal Article
Open access
PDF file
RRRifan Amirul Fatkhur Rokhman
Rifan Amirul Fatkhur Rokhman
TITri Bowo Indrato
Tri Bowo Indrato
ESEndang Dian Setioningsih
Endang Dian Setioningsih
SMShubhrojit Misra
Shubhrojit Misra
High Flow Nasal Canulla (HFNC) is a technique that provides a high flow of heated and humidified gas. HFNC is simpler to use and implement than noninvasive ventilation (NIV) and appears to be a good alternative treatment for hypoxemic acute respiratory failure (ARF). This study aims to help facilitate medical personnel or equipment operators in monitoring the flow that enters the patient's body so that oxygen therapy can be given according to the right dose. This study uses an Arduino microcontroller to process the output flow from the Sensirion SFM-3000 flow sensor, then the processed flow value will be displayed on the TFT LCD. The independent variable in this study is the flow setting value, while the dependent variable is the SFM-3000 flow sensor. The largest error flow value is in the setting at 30 LPM with an error value of 2.70%. The flow value is set using a flowmeter, while the comparison tool used is a flow analyzer (Citrex H3). In the testing phase, the measurement value is 10 LPM to 60 LPM with a time of 5 minutes at each point. Based on the measurements that have been made, the largest error value is obtained at the value of 30 LPM, which is 2.70% and the smallest error value is at the value of 60 LPM, which is 0.74%. Data retrieval using a compressor and central oxygen is very influential on the results of the flow and oxygen concentration. The results obtained are more stable than without the use of a compressor and central oxygen.The conclusion from these results is that the calibrator module has a relative error (error value) that is still within the allowable tolerance limit, which is ±5%. And also the design of this tool is portable and low cost and is made to be used in hospital agencies as a support for maintenance on HFNC equipment

28 May 2022 in Indonesian Journal of electronics, electromedical engineering, and medical informatics
Verified
Journal Article
Open access
PDF file
APAndjar Pudji
Andjar Pudji
FAFarid Amrinsani
Farid Amrinsani
SLSari Luthfiyah
Sari Luthfiyah
LLLusiana Lusiana
Lusiana Lusiana
SMShubhrojit Misra
Shubhrojit Misra
LLLamidi Lamidi
Lamidi Lamidi
Respiratory distress in neonates is one of the biggest problems encountered on a daily basis. Respiratory distress looks like rapid breathing in a newborn. CPAP Bubble is the right treatment in this case. Rise time is the time for airway pressure to reach the maximum standard value. A fast time value can make it possible to bring the breath pressure to a standard level. This study aims to analyze changes in setting flow to rise time using a gasboard sensor 7500E on a CPAP bubble device. The main advantage of this proposed method is that the results are displayed in the form of graphics, portable and there is data storage. This design uses a Gasboard 7500E sensor as a detector of oxygen concentration, a TFT LCD as a graphic display and an SD Card as data storage. The data collection is in the form of the average rise time of oxygen concentration followed by changes in its rate. Data were taken five times with three different CPAPs. The results showed that the increase in the rate affect the rise time of the CPAP oxygen concentration.