8 December 2022 in Jurnal Teknokes
RRRifan Amirul Fatkhur Rokhman
Rifan Amirul Fatkhur Rokhman
High Flow Nasal Canulla (HFNC) is a technique that provides a high flow of heated and humidified gas. HFNC is simpler to use and implement than noninvasive ventilation (NIV) and appears to be a good alternative treatment for hypoxemic acute respiratory failure (ARF). This study aims to help facilitate medical personnel or equipment operators in monitoring the flow that enters the patient's body so that oxygen therapy can be given according to the right dose. This study uses an Arduino microcontroller to process the output flow from the Sensirion SFM-3000 flow sensor, then the processed flow value will be displayed on the TFT LCD. The independent variable in this study is the flow setting value, while the dependent variable is the SFM-3000 flow sensor. The largest error flow value is in the setting at 30 LPM with an error value of 2.70%. The flow value is set using a flowmeter, while the comparison tool used is a flow analyzer (Citrex H3). In the testing phase, the measurement value is 10 LPM to 60 LPM with a time of 5 minutes at each point. Based on the measurements that have been made, the largest error value is obtained at the value of 30 LPM, which is 2.70% and the smallest error value is at the value of 60 LPM, which is 0.74%. Data retrieval using a compressor and central oxygen is very influential on the results of the flow and oxygen concentration. The results obtained are more stable than without the use of a compressor and central oxygen.The conclusion from these results is that the calibrator module has a relative error (error value) that is still within the allowable tolerance limit, which is ±5%. And also the design of this tool is portable and low cost and is made to be used in hospital agencies as a support for maintenance on HFNC equipment
24 November 2022 in Indonesian Journal of electronics, electromedical engineering, and medical informatics
Auscultation is a technique or method most often used by medical personnel in the initial examination of patients. One way is to use a stethoscope. However, this method has its drawbacks because the diagnosis is carried out subjectively and cannot be relied on with the accuracy to diagnose the symptoms of heart defects. Thus, the purpose of this study is to create an IoT system for electronic stethoscopes with BPM value output and make analog filters to eliminate noise interference which was a major obstacle in previous studies. The contribution to this study is to make it easier for medical users to monitor vital conditions, namely BPM remotely and produce BPM values in real-time. The method used in this study was to use a mic condensor placed on the patient's chest to detect pressure changes that occurred. This change in pressure causes a change in the voltage output value on the condensor mic. Output dari mic condenser masuk dan diproses di rangkaian PSA. Output sinyal dari PSA masuk ke mikrokontroler yang telah diprogram. Hasil yang dipeoleh dari pengukuran mengasilkan nilai error pengukuran nilai BPM dari 5 responden dan diperoleh nilai error yang dihasilkan dari responden 1 diperoleh error sebesar 0.33 BPM, responden 2 diperoleh nilai error sebesar 0,67 BPM, responden 3 memiliki nilai error sebesar 0,5 BPM, responden 4 nilai error sebesar 0,67 dan responden 5 mempunyai nilai error sebesar 0,67 BPM. The results of the statistical test were also obtained P-Value>0.05 which explained that the resulting value did not have a significant difference and could be used for medical purposes. This research can help make it easier for doctors to analyze and diagnose symptoms of heart defects because this system is equipped with the detection of disease symptoms.
1 April 2026 in Bulletin of Electrical Engineering and Informatics
Heart sound, or phonocardiogram (PCG), signals are often distorted by noise from respiration, movement, and the surrounding environment, which complicates accurate cardiac feature extraction in portable monitoring systems. This study aims to design and evaluate an effective digital filtering method to enhance PCG signal quality obtained from a low-cost acquisition system based on a condenser microphone sensor and an ESP32 microcontroller. The main contribution of this work is the implementation and comparison of two noise-reduction approaches: Butterworth band-pass filters of various orders and the Kalman filter applied to PCG signals acquired from mannequin-based simulations. Data were recorded for 10 seconds at a 1000 Hz sampling rate, processed in MATLAB, and analyzed using the fast Fourier transform (FFT) to determine the optimal frequency ranges. Experimental results demonstrate that the 8th-order Butterworth band-pass filter achieved the highest signal-to-noise ratio (SNR) improvement, averaging 25.659 dB, outperforming other configurations. These findings indicate that an appropriately tuned Butterworth filter provides a simpler yet robust solution for real-time PCG denoising in embedded systems. Future work will integrate the filtering process directly into the ESP32 firmware and evaluate its performance on human subjects to enhance clinical applicability.