Stanislav Kravchenko

Dr. Stanislav Kravchenko

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 August 2025 in Eastern-European Journal of Enterprise Technologies
Verified
Journal Article
Open access
PDF file
OTOleksii Tretiak
Oleksii Tretiak
Stanislav KravchenkoStanislav Kravchenko
Stanislav Kravchenko
BSBogdan Shestak
Bogdan Shestak
DSDenys Shpitalnyi
Denys Shpitalnyi
MAMariia Arefieva
Mariia Arefieva
AKAnton Kovryga
Anton Kovryga
This study's object is the aerodynamic characteristics of the compressor diffusers in hydrogen-cooled turbogenerators. This paper reports a solution to the task of improving the efficiency of a cooling system discharge unit. This issue relates to enabling the necessary gas consumption while reducing the number of diffuser blades. The problem was solved by introducing a seal with improved technological control capabilities and step-by-step optimization of the diffuser flow part. Another issue is the thermal loads on the power components of the diffuser unit due to the action of circulating currents and temperature gradients. The problem was solved by introducing dielectric and non-magnetic elements into the structure, by additional finning and multi-component design for the diffuser strength circuits. The main result is the designed multi-component diffuser structure with a number of blades of 20 while enabling a head of Hst = 978 mm H2O. The adopted duct opening angle was 20°. Other necessary geometric parameters were determined. The introduction of a multilayer seal made it possible to reduce the gap between the impeller and the diffuser to 0.9 mm. The proposed design was tested on the bench at a manufacturing enterprise. The results of the study are attributed to the use of non-magnetic and dielectric materials (AISI 321 steel and fiberglass), as well as the introduction of additional strength decoupling elements. A special feature of the proposed method is the application of mathematical models based on the basic equations of gas dynamics, taking into account the composition principles of engineering alloys and synthetic materials. This could be achieved via a step-by-step optimization of the design. The proposed structure could be implemented when designing and modernizing hydrogen-cooled turbogenerators

8 August 2025 in Computation
Verified
Journal Article
Open access
PDF file
OTOleksii Tretiak
Oleksii Tretiak
MAMariia Arefieva
Mariia Arefieva
DKDmitriy Kritskiy
Dmitriy Kritskiy
Stanislav KravchenkoStanislav Kravchenko
Stanislav Kravchenko
BSBogdan Shestak
Bogdan Shestak
SSSerhii Serhiienko
Serhii Serhiienko
Gas coolers are critical elements of turbogenerator cooling systems, which ensure the reliability and stability of the thermal mode of high-power electric machines. The aim of this research is to improve the accuracy of thermal calculations of gas coolers by combining analytical methods with numerical CFD-modeling (Computation Fluid Dynamics). The cooler’s total cooling capacity is approximately 3.8 MW, distributed across three identical sections.An analytical calculation of heat transfer for a hydrogen-water gas cooler with finned tubes was performed, using classical dependencies to determine the heat transfer coefficients and pressure losses. The results were verified using three-dimensional CFD-modeling of the hydrogen flow through the cooler using the standard k-ε (k-epsilon) turbulence model. The discrepancy between the results of analytical and numerical calculations is less than 10%. The temperature of the cooled hydrogen at the outlet meets the design requirements (+40 °C); however, areas of uneven temperature distribution were identified that require further design optimization. The study introduces, for the first time, a combined approach using analytical calculations and CFD by thoroughly evaluating the heat exchange between the cooling tube fins and hydrogen. This scientific solution enabled the simulation of hydrogen flow within the multi-stage cooler system. The proposed method has proven to be reliable and can be applied both at the design stage and for the analysis of upgraded cooling systems of turbogenerators.

27 June 2025 in Eastern-European Journal of Enterprise Technologies
Verified
Journal Article
Open access
PDF file
OTOleksii Tretiak
Oleksii Tretiak
Stanislav KravchenkoStanislav Kravchenko
Stanislav Kravchenko
OMOleksii Mykhailychenko
Oleksii Mykhailychenko
VNViacheslav Nazarenko
Viacheslav Nazarenko
SSSerhii Smyk
Serhii Smyk
VSVolodymyr Selevko
Volodymyr Selevko
The object of this study is the thermal and hydraulic characteristics of the oil coolers in a thrust bearing and guide bearing cooling system of hydrogenerators. The study addresses the task to improve the efficiency of the cooling system of the supporting elements of hydrogenerators while maintaining mass and dimension indicators. The main problems in this case are the unbalanced flow of oil within the typical cooling system and different stiffness of the thrust bearing segment supports. The main result is the design of a cooling system structure that ensures effective heat removal from the oil. According to calculations, an oil cooler for a hydrogenerator with a capacity of 56 MW provides removal of 250 kW of losses with a heat transfer margin of 26.2%, for a hydrogenerator with a capacity of 96 MW – 150 kW and 31.8%, respectively. The results are explained by the use of new antifriction materials for supporting elements (fluoroplastic-4) and a higher strength group material for the thrust bearing disk. The designed structure of the cooling system enables operation with preservation of isotropy of cooling liquids and does not have "dead" zones of these liquids flow. A feature of the proposed method for calculating oil coolers is the addition to existing criterion equations of an experimental coefficient B, which takes into account the peculiarity of the geometry of the structure in addition to the nature of the oil flow and gas-dynamic parameters. The action of three-dimensional forces, temperatures, and pressures within the base metal and cooling liquids were comprehensively taken into account. The proposed structures of the thrust bearing and guide bearing, as well as their cooling systems, could be implemented in the design and modernization of medium and high-power hydrogenerators

27 February 2026 in Eastern-European Journal of Enterprise Technologies
Verified
Journal Article
Open access
PDF file
AYAndrii Yehorov
Andrii Yehorov
Stanislav KravchenkoStanislav Kravchenko
Stanislav Kravchenko
ODOleksii Duniev
Oleksii Duniev
OVOleksandr Vasyliev
Oleksandr Vasyliev
DHDenys Hromenko
Denys Hromenko
DODmytro Obidin
Dmytro Obidin
This study explores heat and mass transfer processes in the structural elements of an umbrella-type hydrogenerator, as well as the ventilation and cooling system in the active components of the hydrogenerator. A vertical synchronous air-cooled hydrogenerator with a rated capacity of 60 MW has been investigated. The task addressed relates to the cooling efficiency of generator components. Conventional analytical calculation methods do not make it possible to identify local overheating zones and pressure distribution in complex ventilation channels. Therefore, it becomes necessary to use numerical methods and algorithms to calculate and analyze the cooling efficiency of the generator’s active parts. The main result of this study is the designed structure of the guide channels (blades) of the rotor, which provides the required air flow rate of 45 m3/s. At the same time, the maximum values of the winding temperature do not exceed the permissible values for class F insulation. The CFD calculation detailed the action of the superchargers and showed the real pressure in the channels and the volume of air passing through each section of the generator. The error between the results from CFD modeling and analytical calculations is less than 3%. The results are attributed to the detailed reproduction of the geometry of the ventilation channels in the 3D model, which made it possible to determine the real aerodynamic resistance and cooling medium consumption. The proposed method uses the boundary conditions of the third kind for a comprehensive calculation of the conjugate heat and mass transfer. The proposed structure could be implemented in the design and modernization of air-cooled hydrogenerators.

7 August 2023 in NTU "KhPI" Bulletin: Power and heat engineering processes and equipment
Verified
Journal Article
Open access
PDF file
OTOleksii Tretiak
Oleksii Tretiak
Stanislav KravchenkoStanislav Kravchenko
Stanislav Kravchenko
OBOleg Bogozhavets
Oleg Bogozhavets
VNViacheslav Nazarenko
Viacheslav Nazarenko
AZAnton Zhukov
Anton Zhukov
Представлена робота присвячена методології визначення натягів бандажних кілець методом розрахунку напружень в деталях бандажного вузла ротора. Були проведені: статичний розрахунок центруючого кільця у стані спокою, статичний розрахунок центруючого кільця при номінальній частоті обертання та статичний розрахунок центруючого кільця при угонній частоти обертання. Ці розрахунки вперше були виконані в тривимірній постановці за методом математичного моделювання.

21 August 2024 in Eastern-European Journal of Enterprise Technologies
Verified
Journal Article
Open access
PDF file
OTOleksii Tretiak
Oleksii Tretiak
Stanislav KravchenkoStanislav Kravchenko
Stanislav Kravchenko
SSSerhii Smakhtin
Serhii Smakhtin
DBDmytro Brega
Dmytro Brega
AZAnton Zhukov
Anton Zhukov
YDYevhen Don
Yevhen Don
The jumpers of rotor pole-to-pole connections are highly stressed elements in a hydraulic generator structure. These assemblies often fail due to deformation that exceeds the size of an air gap. Existing methods do not take into account the thermal component and attempts to improve the design are not based on mathematical models that make it possible to perform calculations with an accuracy of more than 50 %. The method devised in this work makes it possible to obtain boundary conditions of the third kind on the basis of three-dimensional mathematical modeling of the ventilation system of the hydraulic unit without simplifications. The method accuracy is explained by taking into account the spatial thermal component. The heat transfer coefficient determined by this method in the pole-to-pole connections area was ~250 W/(m2·K). Using FEM, mathematical modeling of the thermal stress state of pole-to-pole connections was carried out, taking into account mechanical and thermal factors. This made it possible to design the improved connection structure with additional fastening elements, which make it possible to reduce the displacement to 0.03 mm, and the stress to 53 MPa at the rotor rotation frequency of 880 rpm. This design makes it possible to enable reliable operation of the hydraulic unit under the condition of increasing the rotor rotation frequency to overspeed with disconnected combinatorial dependence, provided that the actual stresses are 0.95 % of the material yield strength. The convergence of the values obtained by the proposed method and by the HSS method exceeded 99 %. The practical result is the proposals for the hydraulic generator design modernization