The basic idea of decentralized demand response systems is not new, however, material presented in the subject matter literature is usually limited to general ideas and possible system services. In this paper, the original stochastic decentralized active demand response (DADR) system is presented in the form of an application-ready control algorithm. The results of simulation investigations have confirmed that the proposed stochastic DADR solution, because of its high dynamic response in dealing with disturbance phenomena, might be used as part of both the primary and the secondary load frequency control in electrical power systems. The applicability of the proposed algorithm for control of refrigerators has been numerically tested for various system parameters. Fulfillment of all assumed DADR system requirements concerning high dynamic, “soft” operation, fair share in service as well as minimization of degradation in comfort of use of DADR controlled devices have been confirmed in numerical evaluations.
1 July 2017 in Renewable and Sustainable Energy Reviews
This paper introduces the concept of a battery energy storage system as an emergency power supply for a separated power network, with the possibility of island operation for a power substation with one-side supply. This system, with an appropriately sized energy storage capacity, allows improvement in the continuity of the power supply and increases the reliability of the separated network at a specified time during the limitation of power transmission as a result of damage or disconnection of the main power line. This paper presents and describes a specific method of energy storage system dimensioning based on real measurement data. Based on the obtained parameters, an analysis of the reliability improvement of the considered network was performed. The implementation of the battery energy storage system will contribute to a more than 5-fold reduction in the occurrence of power outages in the time interval from 3 min to 1.5 h, which will clearly reduce the System Average Interruption Frequency Index and System Average Interruption Duration Index factors. In this paper, the network conditions for operational normality and failure are presented and the cost for implementation of an energy storage system (about EUR 1 million) is compared with the possible implementation of an additional power line (about EUR 5 million) to a specific power substation.
1 December 2016 in Bulletin Of The Polish Academy Of Sciences-Technical Sciences
The large variability in power consumption in electrical power systems (EPS) influences not only growth balance losses and technical losses, but also in some cases reduces energy security. Delayed restoration of power generation, combined with unpredictable weather events leading to the loss of generating power can lead to a situation in which to save the stability of the power system there must be introduced in the system a load power limit or even disconnection of end-user in a given area, which will significantly reduce the comfort of use of energy. This situation can be prevented through either the building of new intervention power units or the aggregated use of new energy technologies, such as distributed network resources (DER), which are part of an intelligent Smart Grid network. Such resources bring together virtual power plants (VPP) and demand side management (DSM). The article presents an alternative decentralized active demand response (DADR) system, that by acting on selected groups of loads reduces peak loads with minimized loss of comfort of energy in use for the end-user. The system operates without any communication. The effectiveness of the proposed solution has been confirmed, outlined in test results obtained by the authors from a developed analytical model, which also contains stochastic algorithms to decrease the negative impact of such DSM systems on the power system (power overshoot and oscillation).