Talip Celik

Prof. Dr. Talip Celik

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2015 in Journal of Cranio-Maxillofacial Surgery
Verified
Journal Article
Closed access
FCFatih Mehmet Coskunses
Fatih Mehmet Coskunses
BKBahadir Kan
Bahadir Kan
IMIbrahim Mutlu
Ibrahim Mutlu
UCUlkem Cilasun
Ulkem Cilasun
TCTalip Celik
Talip Celik

10 October 2019 in Australasian Physics & Engineering Sciences in Medicine
Verified
Journal Article
Closed access
PDF file
TCTalip Celik
Talip Celik
YKYasin Kişioğlu
Yasin Kişioğlu

16 October 2020 in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
Verified
Journal Article
Closed access
PDF file
TCTalip Celik
Talip Celik
The purpose of this study is to examine the effects of screw preload values on the bone-plate system. The preload value was taken differently in the literature range from 50 N to 3000 N. These preload value were examined in this study. The finite element method was used to calculate the strain and stress on the models. The long bone, plate and screws were modeled as 3D using CAD software. The finite element models were created using Ansys Workbench software. The convergence and validation study were made for the correct results. The 400 N axial load was applied to the proximal end of bone. The distal end of the bone fixed for boundary condition. The preload values were applied to the screws differently. The results of the finite element analysis were compared and evaluated. The results showed that when the preload values increased, the von Mises stresses and strains on the bone and plate system increased. The critical preload value of the screw is the 500 N. The upper values of this critical value can be damaged bone and plate system. The critical region of the bone is the holes where the screw inserted. In conclusion, the preload values of the screw should not exceed the 500 N for the successful fixation.

20 March 2017 in Australasian Physics & Engineering Sciences in Medicine
Verified
Journal Article
Closed access
PDF file
TCTalip Celik
Talip Celik
IMIbrahim Mutlu
Ibrahim Mutlu
AÖArif Özkan
Arif Özkan
YKYasin Kişioğlu
Yasin Kişioğlu

28 August 2023 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
AAAbdulrahman Al-Sanea
Abdulrahman Al-Sanea
SASerkan Aktas
Serkan Aktas
TCTalip Celik
Talip Celik
YKYasin Kisioglu
Yasin Kisioglu

1 December 2018 in Orthopaedics & Traumatology: Surgery & Research
Verified
Journal Article
Closed access
EUEsat Uygur
Esat Uygur
OPOguz Poyanli
Oguz Poyanli
IMİbRahim Mutlu
İbRahim Mutlu
TCTalip Celik
Talip Celik
FAFuat Akpinar
Fuat Akpinar