We investigate and test the effectiveness of a novel window windcatcher device (WWC), as a means of improving natural ventilation in buildings. Using ANSYS CFX, the performance of the window-windcatcher is compared to a control case (no window-windcatcher), in three different geographic locations (Cardiff, Doha and Amman) which are representative of three different types of atmospheric conditions. The proposed window-windcatcher has been shown to improve both thermal comfort and indoor air quality by increasing the actual-to-required ventilation ratio by up to 9% compared to the control case as per the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) standards. In addition, the locations with minimum velocities have been identified. Those locations correspond to the regions with a lower infection risk of spreading airborne viruses such as SARS-CoV-2, which is responsible for the COVID-19 pandemic.
Building retrofitting plays a critical role in achieving sustainable development and is an efficient way to improve the indoor air quality (IAQ) of existing spaces. The IAQ in classrooms has a significant impact on the health and academic achievement of students. However, improving the IAQ of existing classrooms is challenging if minimum architectural modifications are allowed. Different natural ventilation retrofitting techniques were proposed to improve the IAQ in existing classrooms at Jordan University of Science and Technology, which is located in a hot arid region. Computer simulations were used to analyze the ventilation rate, indoor operative temperature, relative humidity, and CO2 concentration in the base Case classroom and after the implementation of the proposed retrofitting techniques. Simulation results were compared with those obtained in the base case to determine the most efficient natural ventilation retrofitting technique. The best results were obtained by using a solar chimney to assist a wind tower, which resulted in an increase in the comfort hours during the occupation time, an improvement in the average monthly ventilation rate range, a decrease in the CO2 concentration, and an improvement in the relative humidity ratio. An energy-saving of 39% would be achieved compared with the use of split unit air condition systems. Economic assessment of the proposed system using net present value indicates positive economic viability.
Window-windcatchers, a passive ventilation method, have been shown to improve ventilation and enhance thermal comfort. Preliminary characterization of a novel window-windcatcher has been undertaken in a previous work, but no relationship had been identified between the actual ventilation rate (), the wind velocity () and crucial design parameters such as the fins angle ()). In this paper, the relationship that quantifies how the window-windcatcher’s performance depends on and was determined. Additionally, for the first time, the ventilation performance of the window-windcatcher was optimized by studying the effects of and the fins-wall distance () through a Computational Fluid Dynamics parametric study (ANSYS)|. In this optimization approach, the angle and the distance corresponding to the maximum actual-to-required ventilation rate were found to be 80° and 45 cm, respectively. The actual ventilation rate increased by approximately 13.2% compared with the baseline design of the windcatcher ( and equal to 40° and 45 cm, respectively); this corresponds to an increase of approximately 8.6% in the actual-to-required ventilation rate, according to the ASHRAE standards.
Previous studies on window-windcatchers have shown their effectiveness in capturing the prevailing wind and redirecting it into a building, increasing the actual-to-required ventilation ratio by 9%, above what is required by the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE). However, the effect of implementing the proposed system on energy performance, energy costs, and thermal comfort has not been studied. Therefore, here, we investigate and test the implementation of the window-windcatcher on a typical residential building, using a validated DesignBuilder model. Compared to the base case (no window-windcatcher), the total annual energy consumption of the entire building (), and consequently the cost, is reduced by approximately 23.3% (i.e., from 18,143 kWh/year to 13,911 kWh/year) when using the window-windcatcher. The total annual reduction in thermal discomfort hours is estimated to be 290 h, which corresponds to an average monthly reduction of approximately 24 h.
Recent evidence available in the literature has highlighted that the high-energy consumption rate associated with air conditioning leads to the undesired “overcooling” condition in arid-climate regions. To this end, this study quantified the effects of increasing the cooling setpoint temperature on reducing energy consumption and CO2 emissions to mitigate overcooling. DesignBuilder software was used to simulate the performance of a generic building operating under the currently adopted ASHRAE HVAC criteria. It was found that increasing the cooling setpoint temperature by 1 °C will increase the operative temperature by approximately 0.25 °C and reduce the annual cooling electricity consumption required for each 1 m2 of an occupied area by approximately 8 kWh/year. This accounts for a reduction of 8% in cooling energy consumption compared to the ASHRAE cooling setpoint (i.e., t_s = 26 °C) and a reduction in the annual CO2 emission rate to roughly 4.8 kg/m2 °C. The largest reduction in cooling energy consumption and CO2 emissions was found to occur in October, with reduced rates of approximately–1.3 kWh/m2 °C and −0.8 kg/m2 °C, respectively.
Thermal comfort has a great effect on occupants’ productivity and general well-being. Since people spend 80–90% of their time indoors, developing the tools and methods that help in enhancing the thermal comfort for buildings are worth investigating. Previous studies have proved that using passive systems like Trombe walls and solar chimneys significantly enhanced thermal comfort in inside spaces despite that each system has a specific purpose within a specific climate condition. Hence, the main purpose of this study is to design and configure a new dual functional passive system, called a solar wall. The new system combines the Trombe wall and solar chimney, and it can cool or heat based on building needs. Simulation software, DesignBuilder, has been used to configure the Solar Wall and study its impact on indoor operative temperature for the base case. Using the new system, the simulation results were compared with those obtained in the base case and analyzed to determine the most efficient system design parameters and implementation method. The case that gave the best results for solar wall configuration was triple glazed glass and 0.1 cm copper as an absorber (case 11). The results show that using four units (case D) achieves longer thermal comfort levels: 15 to 24 thermal hours during winter (compared to five hours maximum) and 10 to 19 comfort hours in summer (compared to zero).