We develop a spatially dependent generalization to the Wells–Riley model, which determines the infection risk due to airborne transmission of viruses. We assume that the infectious aerosol concentration is governed by an advection–diffusion–reaction equation with the aerosols advected by airflow, diffused due to turbulence, emitted by infected people, and removed due to ventilation, inactivation of the virus and gravitational settling. We consider one asymptomatic or presymptomatic infectious person breathing or talking, with or without a mask, and model a quasi-three-dimensional set-up that incorporates a recirculating air-conditioning flow. We derive a semi-analytic solution that enables fast simulations and compare our predictions to three real-life case studies—a courtroom, a restaurant, and a hospital ward—demonstrating good agreement. We then generate predictions for the concentration and the infection risk in a classroom, for four different ventilation settings. We quantify the significant reduction in the concentration and the infection risk as ventilation improves, and derive appropriate power laws. The model can be easily updated for different parameter values and can be used to make predictions on the expected time taken to become infected, for any location, emission rate, and ventilation level. The results have direct applicability in mitigating the spread of the COVID-19 pandemic.
We investigate and test the effectiveness of a novel window windcatcher device (WWC), as a means of improving natural ventilation in buildings. Using ANSYS CFX, the performance of the window-windcatcher is compared to a control case (no window-windcatcher), in three different geographic locations (Cardiff, Doha and Amman) which are representative of three different types of atmospheric conditions. The proposed window-windcatcher has been shown to improve both thermal comfort and indoor air quality by increasing the actual-to-required ventilation ratio by up to 9% compared to the control case as per the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) standards. In addition, the locations with minimum velocities have been identified. Those locations correspond to the regions with a lower infection risk of spreading airborne viruses such as SARS-CoV-2, which is responsible for the COVID-19 pandemic.
Previous studies on window-windcatchers have shown their effectiveness in capturing the prevailing wind and redirecting it into a building, increasing the actual-to-required ventilation ratio by 9%, above what is required by the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE). However, the effect of implementing the proposed system on energy performance, energy costs, and thermal comfort has not been studied. Therefore, here, we investigate and test the implementation of the window-windcatcher on a typical residential building, using a validated DesignBuilder model. Compared to the base case (no window-windcatcher), the total annual energy consumption of the entire building (), and consequently the cost, is reduced by approximately 23.3% (i.e., from 18,143 kWh/year to 13,911 kWh/year) when using the window-windcatcher. The total annual reduction in thermal discomfort hours is estimated to be 290 h, which corresponds to an average monthly reduction of approximately 24 h.
Calcium signalling is one of the most important mechanisms of information propagation in the body. In embryogenesis the interplay between calcium signalling and mechanical forces is critical to the healthy development of an embryo but poorly understood. Several types of embryonic cells exhibit calcium-induced contractions and many experiments indicate that calcium signals and contractions are coupled via a two-way mechanochemical feedback mechanism. We present a new analysis of experimental data that supports the existence of this coupling during apical constriction. We then propose a simple mechanochemical model, building on early models that couple calcium dynamics to the cell mechanics and we replace the hypothetical bistable calcium release with modern, experimentally validated calcium dynamics. We assume that the cell is a linear, viscoelastic material and we model the calcium-induced contraction stress with a Hill function, i.e. saturating at high calcium levels. We also express, for the first time, the “stretch-activation” calcium flux in the early mechanochemical models as a bottom-up contribution from stretch-sensitive calcium channels on the cell membrane. We reduce the model to three ordinary differential equations and analyse its bifurcation structure semi-analytically as two bifurcation parameters vary—the \(\textit{IP}_3\) concentration, and the “strength” of stretch activation, \(\lambda \). The calcium system (\(\lambda =0\), no mechanics) exhibits relaxation oscillations for a certain range of \(\textit{IP}_3\) values. As \(\lambda \) is increased the range of \(\textit{IP}_3\) values decreases and oscillations eventually vanish at a sufficiently high value of \(\lambda \). This result agrees with experimental evidence in embryonic cells which also links the loss of calcium oscillations to embryo abnormalities. Furthermore, as \(\lambda \) is increased the oscillation amplitude decreases but the frequency increases. Finally, we also identify the parameter range for oscillations as the mechanical responsiveness factor of the cytosol increases. This work addresses a very important and not well studied question regarding the coupling between chemical and mechanical signalling in embryogenesis.
To promote the adoption of Direct Air Capture (DAC) systems, this paper proposes and tests a photovoltaic-powered DAC system in a generic residential building located in Qatar. The proposed DAC system can efficiently reduce CO2 concentration in a living space, thus providing an incentive to individuals to adopt it. The ventilation performance of the building is determined using Computational Fluid Dynamics (CFD) simulations, undertaken with ANSYS-CFD. The CFD model was validated using microclimate-air quality dataloggers. The simulated velocity was 1.4 m/s and the measured velocity was 1.35 m/s, which corresponds to a 3.5% error. The system decarbonizes air supplied to the building by natural ventilation or ventilation according to the ASHRAE standards. Furthermore, the performance of the photovoltaic system is analyzed using the ENERGYPLUS package of the Design Builder software. We assume that 75% of CO2 is captured. In addition, a preliminary characterization of the overall system’s performance is determined. It is determined that the amount of CO2 captured by the system is 0.112 tones/year per square meter of solar panel area. A solar panel area of 19 m2 is required to decarbonize the building with natural ventilation, and 27 m2 is required in the case of ventilation according to the ASHRAE standard.
We construct a spatially-compartmental, individual-based model of the spread of SARS-CoV-2 in indoor spaces. The model can be used to predict the infection rates in a variety of locations when various non-pharmaceutical interventions (NPIs) are introduced. Tasked by the Welsh Government, we apply the model to secondary schools and to Further and Higher Education environments. Specifically, we consider student populations mixing in a classroom and in halls of residence. We focus on assessing the potential efficacy of Lateral Flow Devices (LFDs) when used in broad-based screens for asymptomatic infection or in ‘test-to-release’ scenarios in which individuals who have been exposed to infection are released from isolation after a negative LFD result. LFDs are also compared to other NPIs; we find that, although LFD testing can be used to mitigate the spread of SARS-CoV-2, it is more effective to invest in personal protective equipment, e.g., masks, and in increasing ventilation quality. In addition, we provide an open-access and user-friendly online applet that simulates the model, complete with user tutorials to encourage the use of the model to aid educational policy decisions as input infection data becomes available.