Tan-Nhu NGUYEN

Dr. Tan-Nhu NGUYEN

University of Technology of Compiègne, Compiègne, Hauts-de-France, France

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 February 2020 in Applied Bionics and Biomechanics
Verified
Journal Article
Open access
TNTan-Nhu NGUYEN
Tan-Nhu NGUYEN
MTMarie-Christine Ho Ba Tho
Marie-Christine Ho Ba Tho
TDTien Tuan Dao
Tien Tuan Dao
Simulating deformations of soft tissues is a complex engineering task, and it is even more difficult when facing the constraint between computation speed and system accuracy. However, literature lacks of a holistic review of all necessary aspects (computational approaches, interaction devices, system architectures, and clinical validations) for developing an effective system of soft-tissue simulations. This paper summarizes and analyses recent achievements of resolving these issues to estimate general trends and weakness for future developments. A systematic review process was conducted using the PRISMA protocol with three reliable scientific search engines (ScienceDirect, PubMed, and IEEE). Fifty-five relevant papers were finally selected and included into the review process, and a quality assessment procedure was also performed on them. The computational approaches were categorized into mesh, meshfree, and hybrid approaches. The interaction devices concerned about combination between virtual surgical instruments and force-feedback devices, 3D scanners, biomechanical sensors, human interface devices, 3D viewers, and 2D/3D optical cameras. System architectures were analysed based on the concepts of system execution schemes and system frameworks. In particular, system execution schemes included distribution-based, multithread-based, and multimodel-based executions. System frameworks are grouped into the input and output interaction frameworks, the graphic interaction frameworks, the modelling frameworks, and the hybrid frameworks. Clinical validation procedures are ordered as three levels: geometrical validation, model behavior validation, and user acceptability/safety validation. The present review paper provides useful information to characterize how real-time medical simulation systems with soft-tissue deformations have been developed. By clearly analysing advantages and drawbacks in each system development aspect, this review can be used as a reference guideline for developing systems of soft-tissue simulations.

1 March 2021 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Closed access
TNTan-Nhu NGUYEN
Tan-Nhu NGUYEN
SDStephanie Dakpe
Stephanie Dakpe
MTMarie-Christine Ho Ba Tho
Marie-Christine Ho Ba Tho
TDTien Tuan Dao
Tien Tuan Dao

25 July 2020 in Medical & Biological Engineering & Computing
Verified
Journal Article
Closed access
PDF file
TNTan-Nhu NGUYEN
Tan-Nhu NGUYEN
VTVi-Do Tran
Vi-Do Tran
HNHo Quang Nguyen
Ho Quang Nguyen
TDTien Tuan Dao
Tien Tuan Dao


27 October 2022 in Bioengineering
Verified
Journal Article
Open access
PDF file
DNDuc-Phong NGUYEN
Duc-Phong NGUYEN
TNTan-Nhu NGUYEN
Tan-Nhu NGUYEN
SDStephanie Dakpe
Stephanie Dakpe
MTMarie-Christine Ho Ba Tho
Marie-Christine Ho Ba Tho
TDTien Tuan Dao
Tien Tuan Dao
The 3D reconstruction of an accurate face model is essential for delivering reliable feedback for clinical decision support. Medical imaging and specific depth sensors are accurate but not suitable for an easy-to-use and portable tool. The recent development of deep learning (DL) models opens new challenges for 3D shape reconstruction from a single image. However, the 3D face shape reconstruction of facial palsy patients is still a challenge, and this has not been investigated. The contribution of the present study is to apply these state-of-the-art methods to reconstruct the 3D face shape models of facial palsy patients in natural and mimic postures from one single image. Three different methods (3D Basel Morphable model and two 3D Deep Pre-trained models) were applied to the dataset of two healthy subjects and two facial palsy patients. The reconstructed outcomes were compared to the 3D shapes reconstructed using Kinect-driven and MRI-based information. As a result, the best mean error of the reconstructed face according to the Kinect-driven reconstructed shape is 1.5±1.1 mm. The best error range is 1.9±1.4 mm when compared to the MRI-based shapes. Before using the procedure to reconstruct the 3D faces of patients with facial palsy or other facial disorders, several ideas for increasing the accuracy of the reconstruction can be discussed based on the results. This present study opens new avenues for the fast reconstruction of the 3D face shapes of facial palsy patients from a single image. As perspectives, the best DL method will be implemented into our computer-aided decision support system for facial disorders.