Tien Tuan Dao

Dr. Tien Tuan Dao

Biomedical Engineering, Sorbonne University, Universite de technologie de Compiegne, Compiegne, France
orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 December 2018 in Medical & Biological Engineering & Computing
Verified
Journal Article
Closed access
PDF file
TDTien Tuan Dao
Tien Tuan Dao

6 December 2018 in Applied Bionics and Biomechanics
Verified
Journal Article
Open access
PDF file
TDTien Tuan Dao
Tien Tuan Dao
MTMarie-Christine Ho Ba Tho
Marie-Christine Ho Ba Tho
Finite elasticity theory has been commonly used to model skeletal muscle. A very large range of heterogeneous constitutive laws has been proposed. In this review, the most widely used continuum models of skeletal muscles were synthetized and discussed. Trends and limitations of these laws were highlighted to propose new recommendations for future researches. A systematic review process was performed using two reliable search engines as PubMed and ScienceDirect. 40 representative studies (13 passive muscle materials and 27 active muscle materials) were included into this review. Note that exclusion criteria include tendon models, analytical models, 1D geometrical models, supplement papers, and indexed conference papers. Trends of current skeletal muscle modeling relate to 3D accurate muscle representation, parameter identification in passive muscle modeling, and the integration of coupled biophysical phenomena. Parameter identification for active materials, assumed fiber distribution, data assumption, and model validation are current drawbacks. New recommendations deal with the incorporation of multimodal data derived from medical imaging, the integration of more biophysical phenomena, and model reproducibility. Accounting for data uncertainty in skeletal muscle modeling will be also a challenging issue. This review provides, for the first time, a holistic view of current continuum models of skeletal muscles to identify potential gaps of current models according to the physiology of skeletal muscle. This opens new avenues for improving skeletal muscle modeling in the framework of in silico medicine.

15 November 2016 in Sensors
Verified
Journal Article
Open access
PDF file
HTHalim Tannous
Halim Tannous
Dan IstrateDan Istrate
Dan Istrate
ABAziz Benlarbi-Delaï
Aziz Benlarbi-Delaï
JSJulien Sarrazin
Julien Sarrazin
DGDidier Gamet
Didier Gamet
TDTien Tuan Dao
Tien Tuan Dao
Exergames have been proposed as a potential tool to improve the current practice of musculoskeletal rehabilitation. Inertial or optical motion capture sensors are commonly used to track the subject’s movements. However, the use of these motion capture tools suffers from the lack of accuracy in estimating joint angles, which could lead to wrong data interpretation. In this study, we proposed a real time quaternion-based fusion scheme, based on the extended Kalman filter, between inertial and visual motion capture sensors, to improve the estimation accuracy of joint angles. The fusion outcome was compared to angles measured using a goniometer. The fusion output shows a better estimation, when compared to inertial measurement units and Kinect outputs. We noted a smaller error (3.96°) compared to the one obtained using inertial sensors (5.04°). The proposed multi-sensor fusion system is therefore accurate enough to be applied, in future works, to our serious game for musculoskeletal rehabilitation.

1 July 2012 in Computer Methods in Biomechanics and Biomedical Engineering
Verified
Journal Article
Closed access
TDTien Tuan Dao
Tien Tuan Dao
Frederic MarinFrederic Marin
Frederic Marin
PPP. Pouletaut
P. Pouletaut
FCF. Charleux
F. Charleux
PAP. Aufaure
P. Aufaure
MTM. C. Ho Ba Tho
M. C. Ho Ba Tho
For patients with patterns ranging out of anthropometric standard values, patient-specific musculoskeletal modelling becomes crucial for clinical diagnosis and follow-up. However, patient-specific modelling using imaging techniques and motion capture systems is mainly subject to experimental errors. The aim of this study was to quantify these experimental errors when performing a patient-specific musculoskeletal model. CT scan data were used to personalise the geometrical model and its inertial properties for a post polio residual paralysis subject. After having performed a gait-based experimental protocol, kinematics data were measured using a VICON motion capture system with six infrared cameras. The musculoskeletal model was computed using a direct/inverse algorithm (LifeMod software). A first source of errors was identified in the segmentation procedure in relation to the calculation of personalised inertial parameters. The second source of errors was subject related, as it depended on the reproducibility of performing the same type of gait. The impact of kinematics, kinetics and muscle forces resulting from the musculoskeletal modelling was quantified using relative errors and the absolute root mean square error. Concerning the segmentation procedure, we found that the kinematics results were not sensitive to the errors (relative error < 1%). However, a strong influence was noted on the kinetics results (deviation up to 71%). Furthermore, the reproducibility error showed a significant influence (relative mean error varying from 5 to 30%). The present paper demonstrates that in patient-specific musculoskeletal modelling variations due to experimental errors derived from imaging techniques and motion capture need to be both identified and quantified. Therefore, the paper can be used as a guideline.

20 February 2020 in Applied Bionics and Biomechanics
Verified
Journal Article
Open access
TNTan-Nhu NGUYEN
Tan-Nhu NGUYEN
MTMarie-Christine Ho Ba Tho
Marie-Christine Ho Ba Tho
TDTien Tuan Dao
Tien Tuan Dao
Simulating deformations of soft tissues is a complex engineering task, and it is even more difficult when facing the constraint between computation speed and system accuracy. However, literature lacks of a holistic review of all necessary aspects (computational approaches, interaction devices, system architectures, and clinical validations) for developing an effective system of soft-tissue simulations. This paper summarizes and analyses recent achievements of resolving these issues to estimate general trends and weakness for future developments. A systematic review process was conducted using the PRISMA protocol with three reliable scientific search engines (ScienceDirect, PubMed, and IEEE). Fifty-five relevant papers were finally selected and included into the review process, and a quality assessment procedure was also performed on them. The computational approaches were categorized into mesh, meshfree, and hybrid approaches. The interaction devices concerned about combination between virtual surgical instruments and force-feedback devices, 3D scanners, biomechanical sensors, human interface devices, 3D viewers, and 2D/3D optical cameras. System architectures were analysed based on the concepts of system execution schemes and system frameworks. In particular, system execution schemes included distribution-based, multithread-based, and multimodel-based executions. System frameworks are grouped into the input and output interaction frameworks, the graphic interaction frameworks, the modelling frameworks, and the hybrid frameworks. Clinical validation procedures are ordered as three levels: geometrical validation, model behavior validation, and user acceptability/safety validation. The present review paper provides useful information to characterize how real-time medical simulation systems with soft-tissue deformations have been developed. By clearly analysing advantages and drawbacks in each system development aspect, this review can be used as a reference guideline for developing systems of soft-tissue simulations.

11 February 2015 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
PDF file
AMAndrea Malandrino
Andrea Malandrino
JPJosã© M. Pozo
Josã© M. Pozo
ICIsaac Castro-Mateos
Isaac Castro-Mateos
Attilio FrangiAttilio Frangi
Attilio Frangi
MRMarc M. van Rijsbergen
Marc M. van Rijsbergen
JNJã©Rã´mE Noailly
Jã©Rã´mE Noailly
Capturing patient- or condition-specific intervertebral disc (IVD) properties in finite element models is outmost important in order to explore how biomechanical and biophysical processes may interact in spine diseases. However, disc degenerative changes are often modelled through equations similar to those employed for healthy organs, which might not be valid. As for the simulated effects of degenerative changes, they likely depend on specific disc geometries. Accordingly, we explored the ability of continuum tissue models to simulate disc degenerative changes. We further used the results in order to assess the interplay between these simulated changes and particular IVD morphologies, in relation to disc cell nutrition, a potentially important actor in disc tissue regulation. A protocol to derive patient-specific computational models from clinical images was applied to different spine specimens. In vitro IVD creep tests were used to optimize poro-hyperelastic input material parameters in these models, in function of the IVD degeneration grade. The use of condition-specific tissue model parameters in the specimen-specific geometrical models was validated against independent kinematic measurements in vitro. Then, models were coupled to a transport-cell viability model in order to assess the respective effects of tissue degeneration and disc geometry on cell viability. While classic disc poromechanical models failed in representing known degenerative changes, additional simulation of tissue damage allowed model validation and gave degeneration-dependent material properties related to osmotic pressure and water loss, and to increased fibrosis. Surprisingly, nutrition-induced cell death was independent of the grade-dependent material properties, but was favoured by increased diffusion distances in large IVDs. Our results suggest that in situ geometrical screening of IVD morphology might help to anticipate particular mechanisms of disc degeneration.