Gizem Özlü Özlü Türk

Mrs. Gizem Özlü Özlü Türk

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 January 2026 in Biosensors
Verified
Journal Article
Open access
PDF file
GTGizem Özlü Özlü Türk
Gizem Özlü Özlü Türk
MSMehmet Çağrı Soylu
Mehmet Çağrı Soylu
Flexible biosensors offer rapid and low-cost diagnostics but are often limited by the mechanical and electrochemical instability of polymer-based designs in biological media. Here, we introduce a metallic flexible microcrack transducer that exploits the intrinsic deformability of superelastic nickel–titanium (NiTi) for label-free impedimetric detection. Mechanical bending of NiTi wires spontaneously generates martensitic-phase microcracks whose metal–gap–metal geometry forms the active transduction sites, where functional interfacial layers and captured analytes modulate the local dielectric environment and govern the impedance response. Our approach imparts a novel dielectric character to the alloy, enabling its unexplored application in the megahertz (MHz) frequency domain (0.01–10 MHz) where native NiTi is merely conductive. Functionalization with Escherichia coli (E. coli)-specific antibodies renders these microdomains biologically active. This effectively transforms the mechanically induced microcracks into tunable impedance elements driven by analyte binding. The γ-bent NiTi sensors achieved stable and quantitative detection of E. coli ATCC 25922 in sterile human urine, with a detection limit of 64 colony forming units (CFU) mL−1 within 45 min, without redox mediators, external labels, or amplification steps. This work pioneers the use of martensitic microcrack networks, mimicking self-healing behavior in a superelastic alloy as functional transduction elements, defining a new class of metallic flexible biosensors that integrate mechanical robustness, analytical reliability, and scalability for point-of-care biosensing.

12 December 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
GTGizem Özlü Özlü Türk
Gizem Özlü Özlü Türk
MSMehmet Çağrı Soylu
Mehmet Çağrı Soylu
Flexible biosensors offer rapid and low-cost diagnostics but are often limited by the mechanical and electrochemical instability of polymer-based designs in biological media. Here, we introduce a metallic flexible sensing platform that exploits the intrinsic deformability of superelastic nickel–titanium (NiTi) for label-free impedimetric detection. Mechanical bending of NiTi wires spontaneously generates martensitic-phase microcracks whose metal–gap–metal geometry forms the active transduction sites, where functional interfacial layers and captured analytes modulate the local dielectric environment and governing the impedance response. Functionalization with thiolated monolayers and Escherichia coli-specific antibodies enables these microdomains to modulate interfacial charge transfer in response to analyte binding, creating a direct coupling between mechanical deformation and resulting impedance signal. The γ-bent NiTi sensors achieved stable and quantitative detection of E. coli ATCC 25922 in sterile human urine, with a detection limit of 53 CFU mL⁻¹ within 45 minutes, without redox mediators, external labels, or amplification steps. This work establishes the first use of self-healing martensitic microcracks in a superelastic alloy as functional transduction elements, defining a new class of metallic flexible biosensors that integrate mechanical robustness, analytical reliability, and scalability for point-of-care biosensing.

22 September 2026 in Yüzüncü Yıl Üniversitesi Fen Bilimleri Enstitüsü Dergisi
Verified
Journal Article
Closed access
GTGizem Özlü Özlü Türk
Gizem Özlü Özlü Türk
DSDilek Çökeliler Serdaroğlu
Dilek Çökeliler Serdaroğlu
MDMiriş Dikmen
Miriş Dikmen
Bu çalışma, biyomedikal uygulamalar hedeflenerek, yüksek niyobyum (Nb) ilavesi ve termal oksidasyonun NiTiNb şekil hafızalı alaşımlarının (ŞHA) faz dönüşüm davranışı ve biyouyumluluğu üzerindeki etkisini incelemektedir. Ni/Ti oranının birin altına düşürülmesi ve yüksek Nb ilavesi ile birlikte, alaşımın fizyolojik sıcaklıklarda martenzitik dönüşüm (Ms) göstermesi sağlanmış, böylece tıbbi implantlar için uygun, daha yumuşak ve uyumlu bir faz elde edilmiştir. Bu doğrultuda, alaşımların yüzeyleri yüksek sıcaklıklarda oksitlenmiştir. ICP-MS ölçümleri sonucunda, oksidasyon sıcaklığı arttıkça nikel iyonlarının vücut sıvısına difüzyon hızının azaldığı belirlenmiştir. S650 numunesinin NIH/3T3 fibroblast hücreleri üzerindeki sitotoksik etkileri, hücre canlılığı ve proliferasyonunu değerlendirmeye yönelik bir yöntem olan MTT testi kullanılarak incelenmiştir. S650 numunesinin NIH/3T3 hücreleri üzerinde toksik bir etki göstermediği ve kuyular arasında hücre morfolojisi ve proliferasyonu açısından anlamlı bir fark oluşmadığı gözlenmiştir.