Thomas Larm

Dr. Thomas Larm

Luleå University of Technology, Luleå, Norrbotten, Sweden

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2014 in Water Practice & Technology
Verified
Journal Article
Closed access
TLThomas Larm
Thomas Larm
HAH. Alm
H. Alm
There is a need to revise existing design methods for stormwater pollutant treatment, flow transport and detention facilities. The aim is to increase the accuracy in predicting the performance compared with design only based upon areal and volumetric functions and to optimize design by considering more site-specific data, receiving water quality criteria and forecasted climate effects. During the latest years, flow proportional concentration data from in- and outlets from wet ponds and constructed wetlands, have been compiled. Furthermore, other kind of data from the specific facilities have been compiled, such as areas, volumes, proportion of vegetation, outlet design details and length:width ratio. The parameters are used to revise design methods and are implemented in the operative stormwater and recipient software model StormTac. Design criteria and parameters for calculating design flow and sizing required detention volume are also presented. The climate effects on some of the studied parameters, e.g. design flow and inlet concentration, are discussed. The paper presents the climate factor based upon the hypothesis that it is a function of the design rain duration and reoccurrence time.

2 March 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
TLThomas Larm
Thomas Larm
AWAnna Wahlsten
Anna Wahlsten
JMJIRI MARSALEK
JIRI MARSALEK
Maria ViklanderMaria Viklander
Maria Viklander
The StormTac Web model, representing a low-complexity conceptual model (LCCM), was applied to two urban catchments featuring stormwater quality controls, a stormwater pond or a biofilter. The model calculates annual average runoff from annual precipitation and land-use specific volumetric runoff coefficients and baseflows (in storm sewers), which are multiplied by the corresponding mean stormwater quality constituent concentrations obtained from the recently upgraded StormTac Database, to yield constituent loads. The resulting runoff loads pass through the stormwater quality control facilities (a stormwater pond or a biofilter) where treatment takes place and its efficacy is described by “reduction efficiencies”. For the four selected stormwater quality constituents (TP, Cu, Zn, TSS) and two study catchments, a 201-ha residential Ladbrodammen and an 8.2-ha Sundsvall traffic corridor, the compositions of stormwater entering and leaving the control facilities were calculated by StormTac Web and compared against the measured data. In general, the calculated concentrations were smaller than the measured ones, and these differences were reduced, but not eliminated in all cases, by considering uncertainties in both calculated and measured data. Uncertainties in calculated values consisted of two components, a flow component (assumed as 20%) and a concentration component, which was assumed equal to the relative standard error (RSE) of the data in the StormTac Database. Explanations of differences in calculated and measured stormwater data were discussed with respect to temporal changes and trends in environmental practices and stormwater quality monitoring and enhancement by treatment.


19 November 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
TLThomas Larm
Thomas Larm
AWAnna Wahlsten
Anna Wahlsten
There is a need for tools relating stormwater effluent quality data to the ambient water quality guidelines listed, e.g., in the EU Water Framework Directive. We conducted a literature study and identified four methods to calculate the annual required treatment loads (kg/year) to satisfy the guidelines: (1) StormTac Web, (2) the Vollenweider OECD load model, (3) the model developed by the Swedish Water Authorities and SMHI, and (4) the method using effluent concentration criteria. In this paper, we compile and derive new equations based on these methods to enable calculation of annual acceptable load (kg/year) and annual required treatment load (kg/year) for different types of receiving waters and substances, i.e., not only nutrients but also priority chemicals listed in the Water Framework Directive. Obligatory input data consist of calculated or measured annual flow (runoff and baseflow), actual concentrations and criteria concentrations in the receiving water, or criteria concentration for discharge to the receiving waters. The four methods were applied to address total phosphorus in the urban watercourse of Bällstaån, Sweden. Results showed agreement of the calculated required treatment removals with measured phosphorus concentrations in the receiving water when Methods 1–2 were used but more varied results for Methods 3–4, which neglect the receiving waters concentrations and criteria. Based on these results, we recommend Methods 1–2 for use and further evaluation in projects related to improvements in the quality of receiving waters, as they are based on water quality criteria in the receiving waters themselves. Further investigations regarding input data, complementary measurements, and an evaluation of the validity for substances other than nutrients are recommended to improve the accuracy of calculations.

1 September 2018
Verified
Book Chapter
Closed access
PDF file
SGSnežana Gavrić
Snežana Gavrić
TLThomas Larm
Thomas Larm
HÖHeléne Österlund
Heléne Österlund
JMJiri Marsalek
Jiri Marsalek
AWAnna Wahlsten
Anna Wahlsten
Maria ViklanderMaria Viklander
Maria Viklander