Uddipan Nath

Mr. Uddipan Nath

Electronics, University of Rome Tor Vergata, Rome, Lazio, Italy
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 November 2021 in Inventions
Verified
Journal Article
Open access
PDF file
SBSagnik Banerjee
Sagnik Banerjee
Uddipan NathUddipan Nath
Uddipan Nath
PDPurba Dutta
Purba Dutta
AJAmitkumar V. Jha
Amitkumar V. Jha
Bhargav AppasaniBhargav Appasani
Bhargav Appasani
Nicu BizonNicu Bizon
Nicu Bizon
Metamaterial absorbers, on account of their inherent property of electromagnetic radiation absorption, have become a center of attraction for many researchers in recent times. This paper proposes a unique design of a terahertz metamaterial absorber that can be used to sense biomedical samples. The proposed design consists of two identical circular ring resonators (CRRs) made of aluminum on top of a gallium arsenide (GaAs) substrate. On account of its high field confinement in the sensing regime, a near-to-perfect absorption rate of 99.50% is achieved at a frequency of 2.64 THz, along with a large quality factor (Q-Factor) of 44. The design is highly sensitive to the refractive index changes in the encompassing medium. Hence, the proposed absorber can be used as a refractive index sensor exhibiting a reasonable sensitivity of 1500 GHz/RIU and a figure of merit (FoM) of 25. The refractive index range has been varied in the range of 1.34 to 1.39. As many biomedical samples, including cancerous cells, reside within this range, the proposed sensor can be used for biomedical sensing applications.

4 February 2025 in IEEE Transactions on Plasma Science
Verified
Journal Article
Closed access
SBSagnik Banerjee
Sagnik Banerjee
MKMohammad S. Khan
Mohammad S. Khan
Uddipan NathUddipan Nath
Uddipan Nath
SMSantosh Kumar Mishra
Santosh Kumar Mishra
Bhargav AppasaniBhargav Appasani
Bhargav Appasani
This research aims to propose a terahertz metamaterial-based absorber that can sense the alterations in the enclosing medium’s refractive index. The suggested layout comprises a pair of concentric resonators made of gold, each resembling a ring in shape, and is mounted upon a substrate comprising of gallium arsenide (GaAs). The periodicity of the unit cell in this design is only 48 μm. At 2.47 THz, it achieves a high-quality factor (Q-factor) of 61.75 and a nearly perfect absorption of 99.50%. Parametric analyses have been performed to support the selection of the parameters used in the design. Modifications in the polarization angle do not affect the design and the absorption spectra. Because numerous biomedical samples fall within this range, the refractive index has been adjusted within the range of 1.35 to 1.39. Using the proposed sensor, 560 absorption spectra are obtained for different polarization angles, incident angles, and cell specimens of normal and cancerous skin tissue. Different machine learning algorithms have been used to classify the cells based on the absorption spectrum obtained from the proposed sensor with an accuracy of 100% and a precision and recall of 100% and 100%, respectively, on the test data. The proposed work can pave the way for future research combining machine learning and sensing at the terahertz frequency.

1 July 2021
Verified
Conference Paper
Closed access
SBSagnik Banerjee
Sagnik Banerjee
Uddipan NathUddipan Nath
Uddipan Nath
SHShruti
Shruti
AJAmitkumar V. Jha
Amitkumar V. Jha
SPSasmita Pahadsingh
Sasmita Pahadsingh
ASAvireni Srinivasulu
Avireni Srinivasulu
A terahertz metamaterial absorber is designed in this paper which can sense the changes in the refractive index of the surrounding medium. The design consists of a defected patch inside a square ring on a Gallium Arsenide (GaAs) substrate, which provides a near perfect absorption of 99.8% at 1.9 THz. The quality factor (Q-factor) of this structure at 1.9 THz is 32.167 and its Figure of Merit (FoM) is 6.015 which are the important parameters in sensing application. The absorption frequency varies with the refractive index of the surrounding medium and hence this design can be used as a refractive index sensor. The sensitivity of the sensor is found to be 187 GHz/RIU. The high Q-factor of the design and its high FoM makes the design an excellent refractive index sensor.

11 June 2025 in Sensors
Verified
Journal Article
Open access
PDF file
Uddipan NathUddipan Nath
Uddipan Nath
SBSagnik Banerjee
Sagnik Banerjee
CSCarlo Santini
Carlo Santini
RCRocco Citroni
Rocco Citroni
Fabio ManginiFabio Mangini
Fabio Mangini
Fabrizio FrezzaFabrizio Frezza
Fabrizio Frezza
This study presents a cost-effective Hybrid Metamaterial Absorber (HMA) featuring a simple circular-patterned cylindrical design, comprising an indium antimonide (InSb) resonator on a thin copper sheet. Through numerical simulations, we demonstrate that the structure exhibits temperature-tunable properties and refractive index sensitivity. At 300 K (refractive index = 1), a peak absorption of 99.94% is achieved at 1.797 THz. Efficient operation is observed across a 40 K temperature range and a refractive index spectrum of 1.00–1.05, relevant for thermal imaging and spatial bio-sensing. The simulated temperature sensing sensitivity is 13.07 GHz/K, and the refractive index sensitivity is 1146 GHz/RIU. Parametric analyses reveal tunable absorption through adjustments of the InSb resonator design parameters. Owing to its high efficiency and sensitivity demonstrated in simulations, this HMA shows promise for sensing applications in biotechnology, semiconductor fabrication, and energy harvesting.

31 October 2025 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
SMSantosh kumar Mishra
Santosh kumar Mishra
Uddipan NathUddipan Nath
Uddipan Nath
SBSagnik Banerjee
Sagnik Banerjee
Bhargav AppasaniBhargav Appasani
Bhargav Appasani
OAOm Prakash Acharya
Om Prakash Acharya
Cristian RavariuCristian Ravariu
Cristian Ravariu
Terahertz (THz) metamaterial absorbers have become a prominent research topic in recent years. In this paper, a hexa-band metamaterial absorber is designed for bio-medical sensing applications. The design can detect changes in the surrounding medium’s refractive index and operates in the refractive index range of 1.3–1.4, with six prominent absorption peaks. The proposed structure comprises a square ring resonator made up of gold with a boss-cross structure at the center, on top of a Gallium Arsenide (GaAs) substrate having a thickness of 8 μm. When the surrounding medium’s refractive index is 1.4, it offers six absorption peaks at 0.537 THz, 2.573 THz, 3.025 THz, 3.146 THz, 3.489 THz, 3.7348 THz, with corresponding peak absorption of 75%, 92.9%, 98.4%, 98.71%, 94.1%, and 99.34%, respectively. The structure has been designed at n = 1.4 instead of n = 1, as several biological specimens, such as blood, breast cells, etc., have refractive index in the range of 1.3–1.4, and it offers 6 bands for n = 1.4. This choice was made because many biomedical applications have a refractive index around 1.4. The design parameters were selected through a parametric analysis, so as to achieve maximum absorption peaks. The design has also been tested with different polarization angles, and it has been discovered that the absorber is polarization-insensitive. This design can inspire future research on the biomedical application of THz absorbers.