Computer simulations are challenging in terms of modeling the appropriate behavior of brick masonry structures. These numerical simulations are becoming increasingly difficult due to several design code requirements considered for the technical assessment of brick masonry structures for rehabilitation. In Romania, many brick masonry structures have withstood powerful earthquakes during their lifetime and require rehabilitation works. This paper aims to further assess various simulation challenges regarding the boundary conditions of spandrels and masonry structural behavior. This paper presents a comparative numerical study of two different spandrel-piers scenarios: one considers the link between them as unaffected, and the other attempts to simulate the occurrence of damage by replacing the spandrel’s presence in the initial structure. The proposed model follows the “strong pier–weak spandrel model” and is aimed at practicing engineers. Models are computed with ordinary design software such as Robot Structural Analysis with 2D shells finite elements for masonry walls and, in a more complex manner, software such as Ansys with 3D solid finite elements. Time history analyses are carried out for three distinct accelerograms recorded in Romania. A comparison of the results acquired from these two models is presented and discussed. The purpose of this research is to highlight the importance of proper modeling of unreinforced brick masonry structures to optimize operational and maintenance practices.
1 May 2015 in Mathematical Modelling in Civil Engineering
One of the most destructive natural phenomena is the earthquake. These events destroy lives, goods and disrupt human activities. For this reason the anti-seismic protection of buildings is a very important and of interest subject in Civil Engineering. In the case of structures with a low seismic energy dissipation capacity (for example steel frame structures with Slimdek composite floors), this problem becomes more complicated due to the requirement of dampers. In this paper an experimental study is presented regarding an innovative yielding metallic energy dissipation device, proposed by the author. An experiment is carried out on a shake table. By studying the results from the experiments and from the previous carried out numerical analysis we can conclude that this device provides a high anti-seismic protection for this type of structures
Structural rehabilitation, especially of historical monuments, is a difficult and widely treated subject in order to achieve a better insight regarding their seismic response. In Romania, a lot of historical monuments that require rehabilitation due to seismic actions are encountered. This paper aims to assess the effects of structural retrofitting on a historical monument located in Botoşani County, which withstood during its life cycle important earthquakes. The 20th century monument is located in a seismic active area of North – Eastern Romania, at a distance less than 300 km from Vrancea region where the epicenter of major earthquakes for the Eastern Europe is situated. Two hypotheses for the FE model of the structure were considered, namely with and without the rehabilitation solution. Nonlinear FEM analyses were performed in computer software environments. Using specific modeling tools of the computer program it is intended to simulate linear behaviour of masonry and global response of the structure. Comparisons between the two models were made. The results are used to validate the rehabilitation solution also consisting a source of information for its effects during structural lifetime cycle of the historical church.
Cold-formed steel structures represent a suitable alternative to classical, by now, structural solutions considering the recycling/reuse tendency worldwide as part of the circular economy paradigm. The paper presents a new design approach for CFS profile joints to accurately predict their realistic behavior, based on experimental and numerical investigation of two types of connectors frequently used in the construction industry for manufacturing joints made of CFS profiles: steel-steel pop-rivets (SSPR) and self-tapping screws (STS). The experiments carried out in the case of T-joints subjected to tensile forces tested both solutions. Another significant parameter of the research was the thickness of the steel sheet used to make the CFS profiles. A number of 20 specimens of T-joints made of Cold-Formed Steel (CFS) profiles in total were tested. These consist of five specimens for each of two types of steel sheet thicknesses. The results are relevant for designers because they provide relevant data concerning the limited axial rigidity of T-joints, which are an important instrument in numerical models for achieving the optimum design of the structural system in terms of strength and overall rigidity. Experimental tests calibrate the numerical model that accounts for the axial stiffness of the hinged joints between the CFS profiles. The main parameters of the research are the thickness of the steel sheet and the connector type. The calibrated numerical model used in a case study highlights the advantages of the new approach compared to the classical design procedure based on a conventional hinged connection. Based on the results, the conclusion is that, besides the geometry of the joint and the connector type, the joint stiffness plays a crucial role in the overall behavior of the structural system and should be accounted for in the design process.
1
1 August 2019 in IOP Conference Series: Materials Science and Engineering
The use of cold-formed steel CFS in building design has increased in the last period due to the numerous advantages it brings. However, there are relatively few research works on the behaviour of these types of structures to different loadings, especially compared to the hot-rolled steel structures. Unlike the hot-rolled steel elements, the CFS elements are prone to buckling failure. This paper investigates the stability of a scaled-down CFS structure considering the Eurocode EC and the American International Building Code IBC. First a comparison is done between the two codes in what concerns the stability analysis based on the theoretical aspects. Then, the results from the finite element program are presented, for both EC and IBC, and compared.
1 August 2019 in IOP Conference Series: Materials Science and Engineering
Even if it has been shown that steel beam-to-column connections with extended end plate has a semi-continuous behaviour, many structural analyses consider these joints either fixed or pinned. For advanced structural analysis of connections and frames it is necessary to know the behaviour of the joint. The characteristics of the joint can be identified on the moment-rotation curve. This paper presents a comparative study of the moment-rotation curve for a standardized node calculated according Eurocode 3, and obtained by FEM analysis using IDEASTATICA and ANSYS finite element analysis program. The analyses were performed for the models with non pre-tensioned bolts. Also, an additional study was performed in ANSYS to identify the influence of the thickness of the extended end plate.